OPERATION

Using the Thermometer

High & Low Records
Today's high and low records are displayed for indoor and outdoor
temperature and humidity. Today's records automatically clear at 12:00am
midnight every day. View today's high or low records by pressing the " " or
" " buttons. Press and release again to view current readings.
To manually clear all of today's LOW recorded values, press and release the
" " button to view low records, then press and HOLD the " " button for
2 seconds. Dashes will display to confirm you have cleared the LOW records.
To manually clear all of today's HIGH recorded values, press and release the
" " button to view high records, then press and HOLD the " " button for
2 seconds. Dashes will display to confirm you have cleared the HIGH records.
Moon Phase
Track the phases of the moon, conveyed through simple lunar phase icons:
8
Troubleshooting
If the wireless signal indicator shows no bars:
• Relocate the display and/or the outdoor sensor. The
units must be within 330 ft (100 m) of each other.
• Make sure both units are placed at least 3 feet
No outdoor sensor
(.9 m) away from electronics that may interfere with
reception
the wireless communication (such as TVs, microwaves,
computers, etc).
no bars
• Use standard alkaline batteries (or lithium batteries in
sensor when temperature is below -4ºF/-20ºC). Do not
use heavy duty or rechargeable batteries. NOTE: It
may take up to a few minutes for display and sensor
to synchronize after batteries are replaced.
Display screen
• Check that the batteries are installed correctly.
not working
Batteries may need to be replaced.
Flashing of the outdoor temperature is generally an
indication of wireless interference.
1. Bring both the sensor and display indoors and
Outdoor
remove at least one battery from each.
temperature
2. Make sure the A-B-C switch on both units match.
is flashing or
3. Reinstall the batteries in the outdoor sensor.
showing dashes
4. Reinstall the batteries in the display.
5. Let the units sit within a couple feet of each other
for a few minutes to gain a strong connection.
• Make sure both the display and sensor are placed out
Inaccurate
of direct sunlight and away from any heat sources or
vents (see page 7).
temperature
or humidity
• Make sure both units are positioned away from
moisture sources (see page 7).
If your AcuRite product does not operate properly after trying
the troubleshooting steps, visit www.AcuRite.com or email
support@chaney-inst.com for assistance.