Thank you for your purchase of the Larson Electronics EPLC2-400MH.
WARNING:
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
CRITICAL SAFETY INSTRUCTIONS:
INSTALLATION SHOULD ONLY BE CONDUCTED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NEC AND ANY
RELEVANT LOCAL BUILDING CODES.
RISK OF FIRE OR ELECTRIC SHOCK. FIXTURE INSTALLATION REQUIRES KNOWLEDGE OF FIXTURE'S ELECTRICAL
SYSTEMS. IF NOT QUALIFIED, CONTACT A QUALIFIED ELECTRICIAN.
BE CERTAIN ELECTRICAL POWER IS OFF BEFORE AND DURING INSTALLATION AND MAINTENANCE.
MAKE SURE THE SUPPLY VOLTAGE IS THE SAME AS THE FIXTURE'S RATED VOLTAGE.
TO PREVENT WIRING DAMAGE OR ABRASION, DO NOT EXPOSE WIRING TO EDGES OF SHEET METAL OR SHARP
OBJECTS. SUITABLE FOR DAMP LOCATIONS.
IMPORTANT
READ CAREFULLY BEFORE INSTALLING THIS FIXTURE. SAVE THESE INSTRUCTIONS FOR FUTURE
REFERENCE. THE EPLC2-400MH MUST BE WIRED IN ACCORDANCE WITH NATIONAL ELECTRICAL CODE AND
ALL APPLICABLE LOCAL CODES. PROPER GROUNDING IS REQUIRED FOR SAFETY.
WE STRONGLY ENCOURAGE ONLY A LICENSED ELECTRICIAN INSTALL, OPERATE AND MAINTAIN THIS
PRODUCT. IF YOU ARE NOT QUALIFIED OR UNFAMILIAR WITH ANY ASPECT OF THIS INSTRUCTION SHEET,
CONSULT AN ELECTRICIAN. THERE ARE NO SERVICEABLE PARTS INSIDE.
WARNING: MAKE SURE POWER IS TURNED OFF BEFORE STARTING THE
INSTALLATION OR PERFORMING ANY MAINTENANCE.
RISK OF FIRE/ELECTRIC SHOCK –
RISK OF PERSONAL INJURY –
RISK OF BURN –
ALLOW FIXTURE TO COOL BEFORE SERVICING.
The EPLC2-400MH metal halide, hazardous area light fixture from Larson Electronics produces 34,000 lumens of light capable of
illuminating an area approximately 18,000 square feet in size. Weather proof and NRTL listed for marine use, this metal halide fixture is
available in pendant, ceiling or wall mount versions and is an ideal choice for industrial applications and use in enclosed spaces.
WIRING
This light is highly durable and produces high 34,000 lumen light output in a wide flood pattern. Wiring is through a
convenient 3/4 inch NPT conduit entrance. Three-conductor No. 14 cable (with 90° C minimum insulation) is recommended
for making electrical connections. Wiring is accomplished through the wiring enclosure provided on the fixture. The box is
provided with a size 3/4-in. NPT threaded conduit opening. Wiring methods must comply with NFPA 70 (The National
Electrical Code).
Standard pigtail(flying leads) wiring
We strongly encourage a licensed electrician install this product
where weatherproofing may be required. Universal voltage driver permits operation at 120V, 208V, 240V, or 277V.
Warning: Check product label for correct input voltage!
Attach supply line wires to the appropriate light fixture wires as shown
in the diagram 
Secure each pair of wires according to the diagram. Utilize a junction box or
similar
device
and
connections if installed in a location where water may come in contact with the
unit. Ensure the unit is properly grounded and that wiring is done according to
all local and national electrical/building codes.
Larson Electronics, LLC
400W Metal Halide Light
C1D2 - C2D1 - Ceiling, Wall or Pendant Mount
Instruction Manual
DISCONNECT POWER AT BREAKER BEFORE INSTALLING OR SERVICING.
FIXTURE MAY BECOME UNSTABLE OR DAMAGED IF NOT INSTALLED PROPERLY.
take
precautionary
steps
Phone: (877) 348-9680
, in all locations especially in outdoor areas
for
weatherproofing
all
Fax: (903) 498-3364
EPLC2-400MH
www.larsonelectronics.com
1 of 6

Advertisement

loading

Summary of Contents for Larson Electronics C1D2

  • Page 1 ALLOW FIXTURE TO COOL BEFORE SERVICING. The EPLC2-400MH metal halide, hazardous area light fixture from Larson Electronics produces 34,000 lumens of light capable of illuminating an area approximately 18,000 square feet in size. Weather proof and NRTL listed for marine use, this metal halide fixture is available in pendant, ceiling or wall mount versions and is an ideal choice for industrial applications and use in enclosed spaces.
  • Page 2 7. See label on housing to install proper type of lamp. 8. Install the optics (Globe, Refractor or Enclosed Reflector) and Guard, if desired. 9. Activate supplying circuit to test the assembled luminaire. Larson Electronics, LLC 2 of 6 Phone: (877) 348-9680 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 3 EPLC2-400MH Larson Electronics, LLC Phone: (877) 348-9680 Fax: (903) 498-3364 www.larsonelectronics.com 3 of 6...
  • Page 4 2. Pull the supply wire, with the proper temperature rating as specified in the ballast housing to be installed, into the mount. CEILING WALL BRACKET Figure B Larson Electronics, LLC Phone: (877) 348-9680 Fax: (903) 498-3364 www.larsonelectronics.com 4 of 6...
  • Page 5 Killark, the purchaser should determine the suitability of the product for its intended use, and assumes all risk and liability whatsoever in connection therewith. REMEMBER TO SAVE ONE OF THESE SHEETS FOR MAINTENANCE PERSONNEL Larson Electronics, LLC 5 of 6 Phone: (877) 348-9680 Fax: (903) 498-3364 www.larsonelectronics.com...
  • Page 6: Replacement Parts

    Larson Electronics. THESE INSTRUCTIONS MAY NOT COVER ALL DETAILS OR VARIATIONS OF THIS PRODUCT FOR YOUR EQUIPMENT OR INSTALLATION REQUIREMENTS. SHOULD FURTHER INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT SALES@LARSONELECTRONICS.COM OR BY PHONE AT 1-877-348-9680 FOR FURTHER ASSISTANCE.

This manual is also suitable for: