16 THINGS TO DO AFTER REPLACING IC

Cautions:
Since this page is common to each country, it may not apply to some models in your country. The contents below are the
minimum adjustments required for operation.

16.1. Base Unit

BBIC
Programs for Voice processing, interface for RF and
EEPROM
EEPROM Adjustment parameter data
(country version batch file, default batch file, etc.)
FLASH 1 Voice prompt data
(vary depending on country version)
Note:
(*1) XX: country code, YY: revision number
"XX" and "YY" vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in JIG and PC
(P.52).
(*2) Refer to Check Point (Base Unit) (P.48)

16.2. Handset

BBIC
Programs for Voice processing, interface for RF and
EEPROM
EEPROM Adjustment parameter data
(country version batch file, default batch file, etc.)
FLASH 2 Program
Note:
(*3) XX: country code, YY: revision number
"XX" and "YY" vary depending on the country version. You can find them in the batch file, PQZZ- mentioned in JIG and PC
(P.59).
(*4) Refer to Check Point (Handset) (P.55)
KX-TG1860BXS / KX-TG1860BXT / KX-TCA132CXS / KX-TCA132CXT / KX-TCA130CXS / KX-TCA130CXT
IC
IC
Necessary Adjustment
1. Default batch file: Execute the command "default".
2. Country version batch file: Execute the command
"TCD220XXrevYY". (*1)
3. Clock adjustment: Refer to Check Point (F). (*2)
1. Change the address "0000" of EEPROM to "55".
2. Default batch file: Execute the command "default".
3. Country version batch file: Execute the command
"TCD220XXrevYY". (*1)
4. Clock adjustment: Refer to Check Point (F). (*2)
No need to adjust.
Necessary Adjustment
1. Default batch file: Execute the command "default".
2. Country version batch file: Execute the command
"TCA130XXrevYY". (*3)
3. Clock adjustment: Refer to Check Point (J). (*4)
4. 1.8 V setting and battery low detection: Refer to Check Point
(A), (H) and (I). (*4)
1. Default batch file: Execute the command "default".
2. Country version batch file: Execute the command
"TCA130XXrevYY". (*3)
3. Clock adjustment: Refer to Check Point (J). (*4)
4. 1.8 V setting and battery low detection: Refer to Check Point
(A), (H) and (I). (*4)
No need to adjust.
61