Page 1
RTM-ATCA-9305 IO Installation and Use P/N: 10010926-05 September 2015...
Page 2
Artesyn reserves the right to revise this document and to make changes from time to time in the content hereof without obligation of Artesyn to notify any person of such revision or changes.
Intelligent Platform Management Controller IPMI Intelligent Platform Management Interface NEBS Network Equipment-Building System PCIe PCI Express PICMG PCI Industrial Computer Manufacturers Group RoHS Restriction of Hazardous Substances Rear Transition Module SFP/SFP+ Small Form Factor Optical Transceiver Module RTM-ATCA-9305 IO Installation and Use (10010926-05)
Page 10
Repeated item for example node 1, node 2, ..., node Omission of information from example/command that is not necessary at the time being. Ranges, for example: 0..4 means one of the integers 0,1,2,3, and 4 (used in registers). RTM-ATCA-9305 IO Installation and Use (10010926-05)
Page 11
This manual has been revised and replaces all prior editions. 10010926-04 Part Number Publication Date Description 10010926-00 October 2008 Design availability version 10010926-01 May 2009 Updated face plate graphic, updated functional description chapter, added board identification section; Added Declaration of Conformity RTM-ATCA-9305 IO Installation and Use (10010926-05)
Page 12
Updated IPMI specifications in Features and Module Management Controller sections. Updated IPMI Sensors table. Updated Artesyn OEM Commands section. 10010926-04 May 2014 Re-branded to Artesyn template. 10010926-05 September 2015 Updated Safety Notes Summary and Sicherheitshinweise. RTM-ATCA-9305 IO Installation and Use (10010926-05)
Artesyn intends to provide all necessary information to install and handle the product in this manual. Because of the complexity of this product and its various uses, we do not guarantee that the given information is complete.
Page 14
Changes or modifications not expressly approved by Artesyn Embedded Technologies could void the user's authority to operate the equipment. Board products are tested in a representative system to show compliance with the above mentioned requirements.
Page 15
Only use handles when installing/removing the RTM to avoid damage/deformation to the face plate and/or PCB. Damage of RTM and Front Blade Installing the RTM with other blades may damage the RTM and the front blade. Only install the RTM with the ATCA-9305 blade. RTM-ATCA-9305 IO Installation and Use (10010926-05)
Page 16
Eye Damage Optical SFP/SFP+ modules may emit laser radiation when no cable is connected. This laser radiation is harmful to your eyes. Do not look into the optical lens at any time. RTM-ATCA-9305 IO Installation and Use (10010926-05)
Page 17
When no cable is connected, cover the port with an optical port plug. Environment Environmental Damage Improperly disposing of used products may harm the environment. Always dispose of used products according to your country’s legislation and manufacturer’s instructions. RTM-ATCA-9305 IO Installation and Use (10010926-05)
Page 18
Safety Notes RTM-ATCA-9305 IO Installation and Use (10010926-05)
Verletzungen oder Schäden am System zur Folge haben. Artesyn ist darauf bedacht, alle notwendigen Informationen zum Einbau und zum Umgang mit dem System in diesem Handbuch bereit zu stellen. Da es sich jedoch bei dem System um ein komplexes Produkt mit vielfältigen Einsatzmöglichkeiten handelt, können wir die...
Page 20
Diese Einrichtung kann im Wohnbereich Funkstörungen verursachen; in diesem Fall kann vom Betreiber verlangt werden, angemessene Maßnahmen durchzuführen und dafür aufzukommen. Änderungen, die nicht ausdrücklich von Artesyn erlaubt sind, können Ihr Recht das System zu betreiben zunichte machen. Um die Einhaltung der oben genannten Richtlinien zu beweisen werden die Boards in Referenzsystemen getestet.
Page 21
Beschädigung des Produktes und von Zusatzmodulen Fehlerhafter Ein- oder Ausbau von Zusatzmodulen kann zur Beschädigung des Produktes und der Zusatzmodule führen. Lesen Sie daher vor dem Ein- und Ausbau von Zusatzmodulen die zugehörige Dokumentation und verwenden Sie angemessenes Werkzeug. RTM-ATCA-9305 IO Installation and Use (10010926-05)
Page 22
Laserprodukte für das gesamte RTM. Werden diese Bestimmungen nicht eingehalten, so können körperliche Verletzungen die Folge sein. Umweltschutz Entsorgen Sie alte Batterien und/oder Blades/Systemkomponenten/RTMs stets gemäß der in Ihrem Land gültigen Gesetzgebung, wenn möglich immer umweltfreundlich. RTM-ATCA-9305 IO Installation and Use (10010926-05)
On-board I/O power converters Standard Compliances The product meets the standards listed below: Table 1-1 Standard Compliance Standard Description UL 60950-1 Legal safety requirements EN 60950-1 IEC 60950-1 CAN/CSA C22.2 No 60950-1 RTM-ATCA-9305 IO Installation and Use (10010926-05)
This section lists the physical dimensions and weight of the RTM. Table 1-2 Mechanical Data Feature Value Physical dimension of the main board 322.25 mm x 125.76 mm Physical dimension of the mezzanine board 312.24mmx 94.44mm Weight of RTM 0.580 kg RTM-ATCA-9305 IO Installation and Use (10010926-05)
Boards are shipped without the SFP/SFP+ plug-in modules installed in the cage. You can purchase and install any combination of copper or optical SFP modules on the RTM. For the 10- Gigabit SFP+ ports, use optical SFP+ modules. RTM-ATCA-9305 IO Installation and Use (10010926-05)
Introduction Board Identification This section shows the product label and assembly number, and indicates where the label is located on the product. Figure 1-1 Location of the Label RTM-ATCA-9305 IO Installation and Use (10010926-05)
Table 1-6 Assemble Numbers Configuration Assembly Number Configuration 1 (18 1-Gigabit SFP ports) C0010716-00 Configuration 2 (12 1-Gigabit SFP ports and two C0010717-00 10-Gigabit SFP+ ports) The assembly number also serves as the RTM model number. RTM-ATCA-9305 IO Installation and Use (10010926-05)
Page 28
Introduction RTM-ATCA-9305 IO Installation and Use (10010926-05)
Make sure that the board, when operated in your particular system configuration, meets the environmental requirements specified below. Operating temperatures refer to the temperature of the air circulating around the RTM, and not to component temperatures. RTM-ATCA-9305 IO Installation and Use (10010926-05)
Hardware Preparation and Installation If you integrate the RTM in your own non-Artesyn system, contact your local sales representative for further safety information. Table 2-1 Environmental Requirements Requirement Operating Non-Operating Temperature +5ºC (41ºF) to +40ºC (104ºF) -40ºC (-40ºF) to +70ºC (158ºF)
If not stated otherwise, the temperature should be measured by placing a sensor at the critical temperature spot. Figure 2-1 Critical Temperature Spot RTM-ATCA-9305 IO Installation and Use (10010926-05)
Installing the RTM with other blades may damage the RTM and the front blade.Only install the RTM with the Artesyn ATCA-9305 blade. Only install the RTM with the Artesyn ATCA-9305 blade. Damage of Circuits Electrostatic discharge and incorrect installation and removal of the product can damage circuits or shorten their life.Before touching the product, make sure that you are working in...
Page 33
7. Apply equal and steady pressure to the RTM to carefully slide it into the shelf until you feel resistance. 8. Continue to gently push the RTM until the RTM connectors engage. 9. Squeeze the lever and latch together, and then hook the lower and upper handle into the shelf rail recesses. RTM-ATCA-9305 IO Installation and Use (10010926-05)
Page 34
A blue LED that is not lit indicates that the payload of the front blade and the RTM has been powered up and is active. 14. Plug the interface cable into the face plate connectors, if applicable. RTM-ATCA-9305 IO Installation and Use (10010926-05)
5. Apply equal and steady pressure to the RTM to carefully slide it into the shelf until you feel resistance. 6. Continue to gently push the RTM until the RTM connectors engage. 7. Squeeze the lever and latch together, and then hook the lower and upper handle into the shelf rail recesses. RTM-ATCA-9305 IO Installation and Use (10010926-05)
Page 36
A blue LED that is not lit indicates that the payload of the front blade and the RTM has been powered up and is active. 14. Plug the interface cable into the face plate connectors, if applicable. RTM-ATCA-9305 IO Installation and Use (10010926-05)
RTM, and that the power-down process is on-going. 2. Wait until the blue LEDs on the front blade and RTM are permanently lit. RTM-ATCA-9305 IO Installation and Use (10010926-05)
Page 38
3. Unlatch the upper handle, and then rotate both handles fully outward. 4. Remove the interface cables from the face plate connectors, if applicable. 5. Loosen the screws on the RTM face plate. 6. Remove the RTM from the slot. RTM-ATCA-9305 IO Installation and Use (10010926-05)
RTM. Not complying to these regulations may lead to personal injury. When installing and using optical SFP/SFP+ modules which are classified as laser products, make sure to comply to the respective regulations. RTM-ATCA-9305 IO Installation and Use (10010926-05)
Note that the latch mechanism of your SFP/SFP+ module may be slightly different compared to the latch shown in the figure above. 3. Grasp the SFP/SFP+ module, and then carefully slide it out of the slot. RTM-ATCA-9305 IO Installation and Use (10010926-05)
Page 41
Dirt and damage can render the SFP/SFP+ module inoperable. Only remove the optical plug when you are ready to connect a cable to the SFP/SFP+ module. When no cable is connected, cover the port with an optical port plug. RTM-ATCA-9305 IO Installation and Use (10010926-05)
Page 42
Hardware Preparation and Installation RTM-ATCA-9305 IO Installation and Use (10010926-05)
RTM console port SFP+ Port 1 SFP+ Port 2 HOST COM Front board console Searay connector RTM IPMI reset button Marvell 98DX5126 Ethernet switch Front blade payload reset button 1 Applicable to Configuration 2 only. RTM-ATCA-9305 IO Installation and Use (10010926-05)
P1 to P12 SFP ports These ports provide 1-Gigabit Ethernet connection. P13, P14 SFP+ ports These ports provide 10-Gigabit Ethernet connection. These are only available in Configuration 2. Faceplate Figure 3-3 Face Plate for Configuration 1 RTM-ATCA-9305 IO Installation and Use (10010926-05)
MPC8548 on front board). BRD RST This resets the RTM and the front blade payload. IPMI RST This resets the MMC on the RTM. Hot Swap LED Figure 3-4 Face Plate for Configuration 2 RTM-ATCA-9305 IO Installation and Use (10010926-05)
Table 3-5 SFP Connectors Pin Assignments Signal Name Signal Description VeeT Transmitter Ground TxFault Transmitter Fault Indication TxDisable Transmitter Disable Two wire serial ID Interface Two wire serial ID Interface MOD_DEF0 Module Definition 0 (Grounded in module) RTM-ATCA-9305 IO Installation and Use (10010926-05)
Table 3-6 SFP+ Pin Assignments Signal Name Signal Description VeeT Transmitter signal ground TX_FAULT Transmitter fault TX_DISABLE Transmitter disable Two wire serial interface data line Two wire serial interface clock line MOD_ABS Module absent RTM-ATCA-9305 IO Installation and Use (10010926-05)
Page 50
Transmitter data Transmitter data inverted VeeT Transmitter signal ground COM Ports Table 3-7 Host/RP COM Pin Assignments, P3/P2 Signal Name Signal Description Not connected SIN1 Receive data SOUT1 Transmit data Not connected SGND Signal ground RTM-ATCA-9305 IO Installation and Use (10010926-05)
Signal Description Green Normal operation TX_FAULT detected Yellow Normal operation LOS detected Table 3-9 Other LEDs LED Color Function CR25 Blue Hot swap LED CR36 Out of service (OOS) Amber CR35 Green In Service RTM-ATCA-9305 IO Installation and Use (10010926-05)
Page 52
LEDs and I/O Interfaces RTM-ATCA-9305 IO Installation and Use (10010926-05)
Chapter 4 Functional Description This chapter describes the functional blocks of the RTM. Block Diagram The following figures show the main functional blocks of the RTM. Figure 4-1 Block Diagram for Configuration 1 (18 SFPs) RTM-ATCA-9305 IO Installation and Use (10010926-05)
For more information on IPMI commands, see the System Management chapter of the ATCA-9305 User's Manual. Table 4-1 IPMI Sensors Sensor Name Sensor Type Sensor Number +3.3V MP Voltage 0x1f +12V PP Voltage 0x20 RTM-ATCA-9305 IO Installation and Use (10010926-05)
The supported baud rate for this port is 9600 bps. Table 4-2 Serial Debug Connector Signal no connect PQ_CONSOLE_RX_C PQ_CONSOLE_TX_C no connect signal ground chassis ground chassis ground The serial debug port can be used to execute raw IPMI commands in SIPL protocol. RTM-ATCA-9305 IO Installation and Use (10010926-05)
I2C Read SFP Register 0x30/0x31 0x05 I2C Write SFP Register 0x30/0x31 0x07 Drive EEPROM 0x30/0x31 0x08 Un-Drive EEPROM 0x30/0x31 0x09 For more information on IPMI commands, see the System Management chapter of the ATCA-9305 User's Manual. RTM-ATCA-9305 IO Installation and Use (10010926-05)
Completion Code 4.7.3 Drive EEPROM This command can be used to enable the level translator so that the MMC can access the SFP and other registers. Type Byte Data Field Response Data Completion Code RTM-ATCA-9305 IO Installation and Use (10010926-05)
Functional Description 4.7.4 Un Drive EEPROM This command can be used to disable the level translator. Type Byte Data Field Response Data Completion Code RTM-ATCA-9305 IO Installation and Use (10010926-05)
Page 60
Functional Description RTM-ATCA-9305 IO Installation and Use (10010926-05)
The publications listed below are referenced in this manual. You can obtain electronic copies of Artesyn Embedded Technologies - Embedded Computing publications by contacting your local Artesyn sales office. For released products, you can also visit our Web site for the latest copies of our product documentation.
Page 62
Related Documentation RTM-ATCA-9305 IO Installation and Use (10010926-05)
Need help?
Do you have a question about the RTM-ATCA-9305 IO and is the answer not in the manual?
Questions and answers