Advertisement

Quick Links

NX-AP7520-C6
Indoor Access Point
Switch Series Product
Guide

Advertisement

Table of Contents
loading

Summary of Contents for NODEXON NX-AP7520-C6

  • Page 1 NX-AP7520-C6 Indoor Access Point Switch Series Product Guide...
  • Page 2 Nodexon Networks reserves all copyrights of this document. Any reproduction, excerption, backup, modification, transmission, translation or commercial use of this document or any portion of this document, in any form or by any means, without the prior written consent of Nodexon Networks is prohibited.
  • Page 3 It is intended for the users who have some experience in installing and maintaining network hardware. At the same time, it is assumed that the users are already familiar with the related terms and concepts. Obtaining Technical Assistance  Nodexon Networks Website: https://www.nodexonnetworks.com/  Technical Support Website: https://nodexonnetworks.com/support...
  • Page 4: Product Overview

    · 1 Product Overview Featuring leading 802.11ax, Nodexon NX-AP7520-C6 delivers up to 575Mbps@2.4G and 1.2Gbps@5G. The overall dual-radio, dual-band performance speeds up to 1.775Gbps per device, totally eliminating Gigabit wireless bottlenecks. 1.1 Technical Specifications Table 1-1 Technical Specifications of NX-AP7520-C6...
  • Page 5: Product Image

    EN301 893 MTBF > 200,000H The weight refers to the weight of host and bracket. 1.2 Product Image The AP provides one Ethernet ports (PoE-capable), one Console port, and one power port for external power supply. Figure 1-1 Appearance of NX-AP7520-C6...
  • Page 6: Led Indicators

    · Note 1. Reset button 4. RJ45 Console port 2. LED indicator 5. LAN/PoE port 3. Anti-Theft lock hole 6. 48V DC power port 1.3 LED Indicators Fit AP State Frequency Meaning The AP is NOT receiving power. Or the AP is in Do Not Disturb mode, which can be disabled by software.
  • Page 7: Power Sources

    The AP can be powered either with a DC power adapter or through Power over Ethernet (PoE). The AP requires Nodexon power adapters (If needed, you can buy them from Nodexon). To use a PoE device, make sure it supports the IEEE 802.3af PoE standard.
  • Page 8: Preparing For Installation

    · 2 Preparing for Installation To prevent device damage and bodily injury, please read carefully the safety recommendations described in this chapter. The recommendations do not cover all possible hazardous situations. 2.1 Installation The AP must be installed indoors. To ensure its normal operation, the installation site must meet the following requirements.
  • Page 9: Temperature And Humidity

    Low relative humidity may dry and shrink insulation sheets and cause static electricity that can damage the circuitry inside the device.  High temperature greatly reduces reliability of the device and shortens its service life. Table 2-1 Required Temperature and Humidity for the NX-AP7520-C6 Temperature Relative Humidity -10° C to 50° C (14° F to 122° F) 5% to 95% 2.6 Cleanness...
  • Page 10: Power Supply

    · Table 2-3 Average (mg/m Maximum (mg/m 0.006 0.03 0.04 0.15 0.05 0.15 0.01 2.7 Power Supply  DC power adapter: 48V/0.3A Specifications of Connector Internal Diameter External Diameter Depth Polarity 2.1mm 5.5mm 10mm Internal: positive External: negative 2.8 Installation Tools Common Tools Phillips screwdriver, related copper and fiber cables, bolts, diagonal pliers, cable ties Special Tools...
  • Page 11: Installing The Access Point

    · 3 Installing the Access Point The NX-AP7520-C6 series must be fixed and installed indoors. Before installing the AP, make sure you have carefully read the requirements described in Chapter 2. 3.1 Installation Flowchart 3.2 Before You Begin Before you install the AP, verify that: ...
  • Page 12 ·  Disconnect the device before cleaning it.  Do not wipe the device with a damp cloth.  Do not wash the device with liquid.  Do not open the enclosure when the AP is working.  Fasten the device tightly. 3.4 Installing the Access Point ...
  • Page 13 · Figure 3-2 Aligning the Square Feet with the Mounting Holes Before mounting the AP on the bracket, you must first install the Ethernet cables. Slide the AP onto the bracket in the reverse direction against the arrow on the mounting bracket until it clicks into place.
  • Page 14 · Figure 3-4 Attaching the Mounting Bracket on the Wall Align the square feet on the rear of the AP over the mounting holes on the bracket. See Figure 3-5. Figure 3-5 Aligning the Square Feet with the Mounting Holes Before mounting the AP on the bracket, you must first install the Ethernet cables.
  • Page 15: Removing The Access Point

    Figure 3-6 Mounting the AP on the Bracket When mounting the AP on wall, keep the “Nodexon” logo upright during the installation. The square feet should fit easily into the mounting slots. Do not forcibly push the AP into the slots.
  • Page 16: Connecting Cables

    · Figure 3-11 Removing the Ceiling-Mount AP 3.6 Connecting Cables Connect UTP/STP to the LAN/PoE port on the AP. See Appendix A for supported wiring of twisted pairs. By default, baud rate is set to 9600, data bit 8, parity none, stop bits 1 and flow control none on the console port of the AP.
  • Page 17 ·  Make sure the device and all cables are securely fastened in the rack. Checking Cable Connection  Make sure the UTP/STP cable matches the interface type.  Make sure cables are properly bundled. Checking the Power Supply  Make sure all power cables are properly connected and safe.
  • Page 18: System Debugging

    · 4 System Debugging 4.1 Setting up a Debugging Environment Use a power adapter or PoE to power the AP. Setting up the Environment  Verify that the AP is properly connected to the power source.  Connect the AP to an AC through a twisted pair cable. ...
  • Page 19: Monitoring And Maintenance

    · 5 Monitoring and Maintenance 5.1 Monitoring You can observe the LED to monitor the AP in operation. CLI Commands You can run related commands on the command line interface (CLI) on the AC to remotely monitor the configurations and status of the AP.
  • Page 20: Troubleshooting Flowchart

    & the parameters are set Check that the optical fibers or cables are correctly connected to the ports Contact Nodexon Customer Service Department for any hardware fault 6.2 Troubleshooting LED does not light up after the AP is powered on If you use PoE power supply, verify that the power source is IEEE 802.11af compliant, and then verify that the cable...
  • Page 21 · Follow the above-mentioned two steps. Verify that the AP is configured correctly. Adjust the angle of antennas. Move the client device to adjust the distance between the client and the AP. LED keeps blinking red The LED stays blinking red for a long time, indicating the Ethernet port is not connected. Verify the Ethernet connection. LED keeps blinking green The AP performs initialization after power on.
  • Page 22: Appendix A: Connectors And Media

    · Appendix A: Connectors and Media 1000BASE-T/100BASE-TX/10BASE-T The 1000BASE-T/100BASE-TX/10BASE-T is a 10/100/1000 Mbps auto-negotiation port that supports auto MDI/MDIX. Compliant with IEEE 802.3ab, 1000BASE-T requires Category 5e 100-ohm UTP or STP (STP is recommended) with a maximum distance of 100 meters (328 feet). 1000BASE-T requires all four pairs of wires be connected for data transmission, as shown in Figure A-1.
  • Page 23: Appendix B: Cabling Recommendations

    · Appendix B: Cabling Recommendations During installation, route cable bundles upward or downward along the sides of the rack depending on the actual situation in the equipment room. All cable connectors should be placed at the bottom of the cabinet rather than be exposed outside of the cabinet.
  • Page 24 ·  If cables are to be bent, bind them first but do not tie cable ties within the bend to avoid stress on the cables, which may otherwise cause the wires inside to break, as shown in Figure B-3. Figure B-3 Do Not Tie Cable Ties within the Bend ...
  • Page 25 · 3. Spring washer 1. Flat washer Note 4. Flat washer 2. Nut  When using a stiff cable, fix it near the cable lug to avoid stress on the lug and cable.  Do not use self-tapping screws to fasten terminals. ...

Table of Contents