Ricoh Rex-Rotary A193 Service Manual page 31

Hide thumbs Also See for Rex-Rotary A193:
Table of Contents

Advertisement

SERVICE PROGRAM MODE TABLE
Mode No.
Class
Class 3
1 and 2
Leading Edge
Registration
(Scanning)
4-010 *
Side-to-side
Registration
(Scanning)
4-011 *
Leading Edge
Erase Margin
1
(Scanning)
Trailing Edge
2
Erase Margin
4-012 *
(Scanning)
Left Side
3
Erase Margin
(Scanning)
Right Side
4
Erase Margin
(Scanning)
Scanner Free
Run
4-013
White Plate
Scanning
1
Start Position
White Plate
4-015*
Scanning
Area
2
Function
Adjusts the leading edge registration for
scanning.
(-): The image moves in the direction of
the leading edge
Use the •/∗ key to toggle between + and -.
See "Replacement and Adjustment -
Copy Image Adjustments" for details.
Adjusts the side-to-side registration for
scanning.
(-): The image disappears at the left side.
(+): The image appears.
Use the •/∗ key to toggle between + and -.
See "Replacement and Adjustment -
Copy Image Adjustments" for details.
Adjusts the leading edge margin for
scanning.
Do not adjust this unless the user wishes
to have a scanner margin that is greater
than the printer margin.
Adjusts the trailing edge margin for
scanning.
See the comment for SP 4-012-1.
Adjusts the left side margin for scanning.
See the comment for SP 4-012-1.
Adjusts the right side margin for scanning. 0.0 ~ 9.0
See the comment for SP 4-012-1.
Performs a scanner free run with the
exposure lamp on.
After selecting "1", press Enter or
twice to start this feature. Press
stop.
Adjusts the scanning start position on the
white plate for auto shading.
The default is 6 mm from the leading
edge. The setting specifies how far
scanning starts from the default position.
Adjusts the width of the area on the white
plate (in the sub scan direction) that is
scanned for auto shading.
The default is 5 mm (for 41 - 400%
reproduction ratios) or 6.5 mm (25 - 40%).
The current setting specifies the
difference from these defaults.
28
9 May 1997
Settings
- 2.0 ~ + 9.0
0.5 mm/step
+ 0.0 mm
- 6.0 ~ + 6.0
0.1 mm/step
+ 0.0 mm
0.0 ~ 9.0
0.1 mm/step
1.0 mm
0.0 ~ 9.0
0.1 mm/step
1.0 mm
0.0 ~ 9.0
0.1 mm/step

1.0 mm
0.1 mm/step
1.0 mm
0: No
1: Yes
to
- 3.0 ~ + 6.0
0.5 mm/step
0 mm
- 3.0 ~ + 6.0
0.5 mm/step
0 mm

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rex-rotary a224

Table of Contents