Nibe SCA 41 Installer Manual
Nibe SCA 41 Installer Manual

Nibe SCA 41 Installer Manual

Docking kit for f750 with ahps as well as external additional heat
Hide thumbs Also See for SCA 41:

Advertisement

Available languages

Available languages

Quick Links

Installatörshandbok
SCA 41
Installatörshandbok Dockningssats för F750 med AHPS
SE
samt extern tillsats
Installer manual Docking kit for F750 with AHPS as well
GB
as external additional heat
Asentajan käsikirja Liitäntäsarja F750:lle AHPS:llä sekä
FI
ulkoisella lisälämmönlähteellä
IHB SE 1515-3
331140

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCA 41 and is the answer not in the manual?

Questions and answers

Summary of Contents for Nibe SCA 41

  • Page 1 Installatörshandbok SCA 41 Installatörshandbok Dockningssats för F750 med AHPS samt extern tillsats Installer manual Docking kit for F750 with AHPS as well as external additional heat Asentajan käsikirja Liitäntäsarja F750:lle AHPS:llä sekä ulkoisella lisälämmönlähteellä IHB SE 1515-3 331140...
  • Page 3 Installatörshandbok - SCA 41 Allmänt Detta tillbehör används för att docka F750 tillsammans med AHPS till solvärme, extern tillsats och prioriterad tillsats. Dessa externa värmekällor kan sedan användas för uppvärmning och varmvattenproduktion. Det finns även en funktion, extra varmvatten, som höjer temperaturen i AHPS för att medge en större total till-...
  • Page 4 Innehåll 1 st Tejp 1 st 2-vägsventil, avstängningsventil (QN32) 4 st Temperaturgivare för inomhusbruk (BT6), 1 st 3-vägs shuntventil (QN11) (BT7), (BT52), (BT54) 1 st Apparatlåda (AA25) 1 st Temperaturgivare för solfångare (BT53) 2 st Avluftningsslang 1 st Ventilkoppel (GP31) 1 st Avluftningskonsol 2 st...
  • Page 5 Komponentplacering apparatlåda (AA25) AA7-X2 AA5-S2 AA5-X4 AA5-X2 AA5-F1 AA5-X9 Elkomponenter Automatsäkring, 10A Anslutningsplint, spänningsmatning Tillbehörskort AA5-X2 Anslutningsplint, givare och extern bloc- kering AA5-X4 Anslutningsplint, kommunikation AA5-X9 Anslutningsplint, cirkulationspump och shunt AA5-S2 DIP-switch AA5-F1 Finsäkring, T4AH250V Extra reläkort AA7-X2 Anslutningsplint, shunt och avstängnings- ventil Beteckningar i komponentplacering enligt standard IEC 81346.
  • Page 6 Ombyggnad av F750 2. Plugga anslutningen på kopplet med bipackad klämringsmutter och plugg (Ø15 mm). Allmänt 1. Stäng av värmepumpen och slå av strömmen på Plugg säkerhetsbrytaren. 2. Ta bort frontluckorna enligt beskrivning i värme- pumpens installatörshandbok. 3. Töm F750 på vatten samt släpp trycket i klimatsy- stemet om värmepumpen blivit installerad tidigare.
  • Page 7 Cirkulationspump (GP1) 3. Montera flexröret och planpackning på värmebä- 1. Demontera röret ovanför värmebärarpumpen rarpumpen (GP1). (GP1). Flexrör Planpackning Rör 2. Montera 2 medlevererade o-ringar i spåren på vinkelkopplingen. Sätt ihop vinkelkopplingen med 4. Dra flexröret till baksidan av F750. flexröret som har honanslutning.
  • Page 8 Påfyllningsventil (QM10) Elpatronanslutning 1. Montera 2 bipackade o-ringar Ø28 mm i spåren OBS! på kopplingen på det andra flexröret. Backventilen i påfyllningsventilen (QM10) i F750 ska demonteras för att det inte ska kunna uppstå undertryck i AHPS. O-ringar 1. Demontera backventilen som sitter innanför påfyll- ningsventilen (QM10).
  • Page 9 4-vägskoppling 1. Demontera klämringsmuttern med plugg från dockningsanslutningen, returledning (XL9) på 4- vägskopplingen i F750. 4-vägskoppling Klämringsmutter med plugg 2. Montera en medlevererad klämring i dockningsan- slutningen (XL9). Klämring Stödhylsa Mutter QN32...
  • Page 10 Röranslutning extra varmvatten Principschema QN10 Växelventil, klimatsystem/varmvattenberedare QN27 Växelventil, cirkulation klimatsystem Förklaring SCA 41 AHPS AA25 Apparatlåda med tillbehörskort EB100 F750 Temperaturgivare, varmvattenladdning, styran- Temperaturgivare, varmvatten, styrande BT63 Temperaturgivare, värmebärare fram efter elpa- Temperaturgivare, varmvatten topp, visande tron GP31 Ventilkoppel, begränsning av hög temperatur...
  • Page 11 Allmänt Röranslutningar AHPS Fem flexrör med tillhörande isolering ingår i SCA 41. XL13 XL18 XL46 XL47 XL14 All övrig rördragning ska ske med 22 mm rör och snäva böjar ska undvikas. TÄNK PÅ! För att undvika onödiga värmeförluster bör rören isoleras.
  • Page 12 Övre rörfästet Ventilkoppel (WP5-GP31) 1. Montera 3 st buntband i det bipackade rörfästet. 1. Anslut det bipackade ventilkopplet (GP31) på an- slutningarna för varmvatten (XL4) respektive kall- 2. Montera 7 st buntband med clips i det bipackade vatten (XL3) på AHPS (CP1). rörfästet.
  • Page 13 Avstängningsventil WP5-QN32 2. Montera ett flexrör från varmvattenanslutningen (XL4) i ventilkopplet (GP31) till kallvattenanslutning- 1. Montera avstängningsventilen (QN32) på AHPS en (XL3) i F750 (EB100). (CP1) enligt bild nedan. Avstängningsventil (QN32) Ställmotor (QN32) EB100-XL9 Luftnippel CP1-XL47...
  • Page 14 Shunt WP5-QN11 Nedre rörfästet 1. Montera shunten (QN11) på AHPS (CP1) enligt bild 1. Montera 4 st buntband i det bipackade rörfästet. nedan. Shuntventil (QN11) Shuntmotor (QN11) Från cirkulationspump 2. Montera rörfästet på AHPS. (EB100-GP1) CP1-XL46 Till elpatron (EB100-EB1) CP1-XL18 Luftnippel Avluftning 1.
  • Page 15 Pump- och tryckfallsdiagram Vidstående diagram visar pumpkapacitet med AHPS dockad till F750, som i detta fall då ersätter motsvaran- de diagram i Installatörshandboken för F750. Tryck Tryck Tillgängligt externt tryck, klimatsystem med shunt WP5-QN11 öppen Tillgängligt externt tryck, klimatsystem med shuntWP5-QN11 öppen (kPa) (kPa) GP6 läge III...
  • Page 16 Röranslutning tillsats Principschema extern och prioriterad tillsats Förklaring Extern tillsats Backventil AHPS EB100 F750 SCA 41 AA25 Apparatlåda med tillbehörskort Beteckningar enligt standard IEC 61346. Principschema extern tillsats - WP5 -AA25 -EB100 -EM2 -EM2-RM2 -WP5-BT52 -CP1 OBS! Detta är ett principschema. Verklig anläggning skall projekteras enligt gällande normer.
  • Page 17 Prioriterad tillsats Cirkulationspump, tillsats Backventil AHPS EB100 F750 SCA 41 AA25 Apparatlåda med tillbehörskort BT52 Temperaturgivare, prioriterad tillsats Medlevereras inte SCA 41. Beteckningar enligt standard IEC 61346. Principschema prioriterad tillsats - WP5 -AA25 -EB100 -EM1 -EM1-RM3 -WP5-BT52 -EM1-GP4 -CP1 -FQ1...
  • Page 18 Se Installatörshandbok för AHPS för ytterligare instruk- tioner. Anslutning av tillsats till AHPS XL46 XL47 AHPS behöver inte tömmas på vatten före installation av SCA 41. 1. Anslut tillsatsens (EM1) eller (EM2) framledning till T-kopplingen ovanför framledningsanslutningen T-koppling (XL46) i AHPS (CP1). CP1-XL47 T-koppling För att undvika onödiga värmeförluster bör rören iso-...
  • Page 19 Röranslutning sol Principschema Förklaring EP30 Solsats Cirkulationspump, sol AHPS EB100 F750 SCA 41 AA25 Apparatlåda med tillbehörskort BT53 Temperaturgivare, solfångare BT54 Temperaturgivare, solslinga Beteckningar enligt standard IEC 61346. Principschema sol - WP5 -AA25 -EB100 -WP5-BT53 -CP1 -EP30 -XL13 -GP4 -WP5-BT54 -XL14 OBS! Detta är ett principschema.
  • Page 20 Anslutning av solfångare till AHPS XL13 XL14 AHPS behöver inte tömmas på vatten före installation av SCA 41. 1. Anslut framledningen (från solfångaren) till anslut- ning för framledning (XL13). 2. Anslut returledningen (till solfångaren) till anslut- ningen för returledning (XL14).
  • Page 21 SCA 41. topplåten och stommen. 5. Montera frontplåten på AHPS. OBS! Om matningskabeln är skadad får den endast ersättas av NIBE, dess serviceombud eller lik- nande behörig personal för att undvika even- tuell fara och skada. OBS! Ø 10 mm För att undvika störningar får kommunika-...
  • Page 22 Anslutning av kommunikation Anslutning av matning Detta tillbehör innehåller ett tillbehörskort (AA5) som Apparatlådan (AA25) levereras med matningskabel ska anslutas direkt till värmepumpen på ingångskortet med stickkontakt (W101, längd 3,0 meter) monterad (plint AA3-X4). från fabrik. Om flera tillbehör ska anslutas eller redan finns instal- lerade måste nedanstående instruktion följas.
  • Page 23 Montering av givare Temperaturgivare, solfångare (WP5-BT53) monteras med värmeledningspasta och fixeras med buntband. Givare, varmvattenladdning (WP5-BT6), varmvatten topp (WP5-BT7)och solslinga (WP5-BT54) placeras i därför avsedda dykrör i AHPS, se bild nedan. Fäst givarkablarna med bifogade plastclips. Givaren placeras i solfångarens dykrör vid utloppet från solfångaren.
  • Page 24 Anslutning av cirkulationspump prioriterad AA5-S2 AA5-X2 AA5-X9 tillsats (EM1-GP4) Anslut cirkulationspumpen (EM1-GP4) till AA5-X9:2 (230V), X1:1 (N) och X1:3 (PE) i apparatlådan (WP5- AA25). AA25 Externt -X10 AA5-X10 AA5-X1 AA5-X4 AA5-X9 Anslutning av fabriksmonterat kablage De utgående kablagen (W104), (W105), (W106), (W107) och (W108) från apparatlådan (WP5-AA25) ansluts internt på...
  • Page 25 Anslutning av extern tillsats Anslut extern tillsats, via en potientialfri kontakt, till AA7-X2:6 (N) och AA7-X2:5 (230 V) i apparatlådan (WP5-AA25). AA7-X2 1 2 3 4 5 6 AA25 Externt Extern tillsats Anslutning av eventuell nödkylning För att undvika att det blir för varmt i den externa till- satsen (EM1), (EM2), (EP30) finns möjlighet att koppla in kylfunktion.
  • Page 26 Startguiden Startguiden visas vid första uppstart efter värmepumps- installationen, men finns även i meny 5.7. Menysystemet Om du inte aktiverar SCA 41 via startguiden kan du göra detta i menysystemet. Meny 5.2 - systeminställningar Aktivering/avaktivering av tillbehör. Meny 5.3.13 - AHPS-dockning Aktivering/avaktivering av "solvärme", "prioriterad...
  • Page 27 Elschema...
  • Page 29 Installer manual - SCA 41 General This accessory is used to dock F750 with AHPS to solar heating, external additional heat and prioritised addi- tional heat. These external heat sources can then be used for heating and hot water production.
  • Page 30 Contents Tape 2-way valve, shut-off (QN32) Temperature sensor for indoor use (BT6), 3-way shunt valve (QN11) (BT7), (BT52), (BT54) Unit box (AA25) Temperature sensor for solar panel (BT53) Vent hose Valve connector (GP31) Venting bracket Angle connection Shut-off valve (QM35) Non-return valve (RM1) Cable ties Cable tie with clips...
  • Page 31 Component location unit box (AA25) AA7-X2 AA5-S2 AA5-X4 AA5-X2 AA5-F1 AA5-X9 Electrical components Miniature circuit breaker, 10 A Terminal block, power supply Accessory card AA5-X2 Terminal block, sensors and external blocking AA5-X4 Terminal block, communication AA5-X9 Terminal block, circulation pump and shunt AA5-S2 DIP switch...
  • Page 32 Conversion of F750 2. Plug the connection on the connector with the supplied compression ring nut and plug (Ø15 mm). General 1. Shut off the heat pump and turn off the current Plug on the safety breaker. 2. Remove the front panels according to the descrip- tion in the heat pump installation manual.
  • Page 33 Circulation pump (GP1) 3. Install the flexible pipe and flat gasket on the 1. Remove the pipe above the heating medium pump heating medium pump (GP1). (GP1). Flexible pipe Flat gasket Pipe 2. Install 2 supplied O-rings in the groove on the angle connector.
  • Page 34 Filler valve (QM10) Immersion heater connection 1. Install 2 enclosed o-rings Ø28mm in the grooves NOTE on the connector on the other flexible hose. The non-return valve in the filler valve (QM10) in F750 must be removed to prevent vacuum in AHPS.
  • Page 35 4-way connector 1. Remove the compression ring nut with plug from the docking connection, return line (XL9) on 4-way connector in F750. 4-way connector Compression ring nut with plug 2. Install the supplied compression ring on the dock- ing connection (XL9). Compression ring Support bush Nuts...
  • Page 36: Outline Diagram

    Pipe connection extra hot water Outline diagram QN10 Shuttle valve, climate system/water heater QN27 Reversing valve, circulation climate system Explanation SCA 41 AHPS AA25 Unit box with accessory card EB100 F750 Temperature sensor, hot water charging, control Temperature sensor, hot water, control...
  • Page 37 Five flexible pipes with corresponding insulation in- XL13 XL18 XL46 XL47 XL14 cluded in SCA 41. All other pipe routing must be carried out with 22 mm copper pipe and tight bends must be avoided. Caution To prevent unnecessary heat losses insulate the pipes.
  • Page 38 Upper pipe mounting Valve connector (WP5-GP31) 1. Install 3 x cable ties in the enclosed pipe mountings. 1. Connect the supplied valve connector (GP31) on the connections for hot water (XL4) respectively 2. Install 7 x cable ties with clips in the enclosed pipe cold water (XL3) on AHPS (CP1).
  • Page 39 Shut-off valveWP5-QN32 2. Install a flexible pipe from the hot water connection (XL4) in the valve connector (GP31) to the cold 1. Install the shut-off valve (QN32) to AHPS (CP1) as water connection (XL3) in F750 (EB100). illustrated below. Shut-off valve (QN32) Actuator motor (QN32)
  • Page 40 Shunt WP5-QN11 Lower pipe mounting 1. Install the shunt (QN11) to AHPS (CP1) as illustrated 1. Install 4 x cable ties in the enclosed pipe mountings. below. Shunt valve (QN11) Shunt motor (QN11) From circulation pump 2. Install the pipe mounting on AHPS. (EB100-GP1) CP1-XL46 To immersion heater...
  • Page 41 Pump and pressure drop diagrams The adjacent diagram shows the pump capacity with AHPS docked to F750, which, in this case replaces the corresponding diagram in the Installation manual for F750. Pressure Tryck Tillgängligt externt tryck, klimatsystem med shunt WP5-QN11 öppen Available external pressure, climate system with shunt WP5-QN11 open (kPa) (kPa)
  • Page 42 Pipe connection additional heat Outline diagram external and prioritised additional heat Explanation External additional heat Non-return valve AHPS EB100 F750 SCA 41 AA25 Unit box with accessory card Designations according to standard IEC 61346. Outline diagram external additional heat - WP5 -AA25 -EB100...
  • Page 43 Non-return valve AHPS EB100 F750 SCA 41 AA25 Unit box with accessory card BT52 Temperature sensor, prioritised additional heat Not supplied SCA 41. Designations according to standard IEC 61346. Outline diagram prioritised additional heat - WP5 -AA25 -EB100 -EM1 -EM1-RM3 -WP5-BT52...
  • Page 44: Pipe Connections

    Connecting additional heat to AHPS XL46 XL47 AHPS does not need to be drained of water prior to installation of SCA 41. 1. Connect the additional heat (EM1) or (EM2) supply line to the T-coupling above the supply line connec- T-coupling tion (XL46) in AHPS (CP1).
  • Page 45 Pipe connection solar Outline diagram Explanation EP30 Solar kit Circulation pump, solar AHPS EB100 F750 SCA 41 AA25 Unit box with accessory card BT53 Temperature sensor, solar panel BT54 Temperature sensor, solar coil Designations according to standard IEC 61346. Outline diagram solar...
  • Page 46 XL13 XL14 AHPS does not need to be drained of water prior to installation of SCA 41. 1. Connect supply line (from the solar panel) to con- nection for supply line XL13. 2. Connect return line (to solar panel) to connection for return line (XL14).
  • Page 47: Electrical Connection

    SCA 41. 5. Install the front panel on AHPS. NOTE If the supply cable is damaged, only NIBE, its service representative or similar authorised person may replace it to prevent any danger and damage.
  • Page 48: Connecting Communication

    Connecting communication Connecting the supply This accessory contains an accessory board (AA5) that The unit box (AA25) is supplied with supply cable with must be connected directly to the heat pump on the plug (W101, length 3,0 meters) installed from the input board (terminal block AA3-X4).
  • Page 49: Installing The Sensor

    Installing the sensor Temperature sensor, solar panel (WP5-BT53) is installed with heat conducting paste and secured with cable Sensor, hot water charging WP5-BT6, hot water top ties. (WP5-BT7) and solar coil WP5-BT54 are therefore placed in the designated submerged tube in AHPS, see image below.
  • Page 50: Connecting Sensors

    Connecting circulation pump prioritised ad- AA5-S2 AA5-X2 AA5-X9 ditional heat (EM1-GP4) Connect the circulation pump (EM1-GP4) to AA5-X9:2 (230V), X1:1 (N) and X1:3 (PE) in the unit box (WP5- AA25). AA25 External -X10 AA5-X10 AA5-X1 AA5-X4 AA5-X9 Connection of factory fitted cables The outgoing cabling (W104), (W105), (W106), (W107) and (W108) from the unit box (WP5-AA25) is internally connected on AHPS, shut off valve and shunt valve.
  • Page 51: Dip Switch

    Connecting external additional heat Connect external additional heat, via a potential-free contact, to AA7-X2:6 (N) and AA7-X2:5 (230 V) in the unit box (WP5-AA25). AA7-X2 1 2 3 4 5 6 AA25 External External addition Connecting any emergency cooling To prevent it becoming too hot in the external addition- al heat ((EM1), (EM2),), (), (EP30) it is possible to connect a cooling function.
  • Page 52: Start Guide

    The start guide appears upon first start-up after heat pump installation, but is also found in menu 5.7. Menu system If you do not activate SCA 41 via the start guide, this can be done in the menu system. Menu 5.2 -system settings Activating/deactivating of accessories.
  • Page 53: Electrical Circuit Diagram

    Electrical circuit diagram...
  • Page 55 Asentajan käsikirja - SCA 41 Yleistä Tätä lisävarustetta käytetään F750:n liitäntään yhdessä AHPS:n kanssa aurinkokeräimeen, ulkoiseen lisäläm- mönlähteeseen ja priorisoituun lisälämmönlähteeseen. Näitä ulkoisia lisälämmönlähteitä voidaan sitten käyttää lämmitykseen ja käyttöveden lämmitykseen. Käytettävissä on myös lisäkäyttövesitoiminto, joka nostaa AHPS:n lämpötilaa salliakseen suuremman käyttövesimäärän.
  • Page 56 Sisältö 1 kpl Teippi 1 kpl 2-tieventtiili, sulkuventtiili (QN32) 4 kpl Lämpötila-anturi sisäkäyttöön (BT6), (BT7), 1 kpl 3-tieshunttiventtiili (QN11) (BT52), (BT54) 1 kpl Kojerasia (AA25) 1 kpl Lämpötila-anturi aurinkokeräimelle (BT53) 2 kpl Ilmausletku 1 kpl Venttiililiitäntä (GP31) 1 kpl Ilmauskannatin 2 kpl Kulmaliitin 1 kpl...
  • Page 57 Komponenttien sijainti kytkentärasia (AA25) AA7-X2 AA5-S2 AA5-X4 AA5-X2 AA5-F1 AA5-X9 Sähkökomponentit Automaattivaroke, 10A Liitinrima, jännitteensyöttö Lisävarustekortti AA5-X2 Liitinrima, anturi ja ulkoinen esto AA5-X4 Liitinrima, tiedonsiirto AA5-X9 Liitinrima, kiertovesipumppu ja shuntti AA5-S2 DIP-kytkin AA5-F1 Pienjännitevaroke, T4AH250V Lisärelekortti AA7-X2 Liitinrima, shuntti ja sulkuventtiili Komponenttikaavion merkinnät standardin IEC 81346 mukaan.
  • Page 58 F750:n muutos 2. Tulppaa liitäntä puserrusrengasmutterilla ja tulpalla (Ø15 mm). Yleistä 1. Kytke lämpöpumppu pois päältä ja katkaise virta Tulppa turvakytkimellä. 2. Irrota etuluukut asennusohjeen mukaisesti. 3. Tyhjennä F750 vedestä ja päästä paine lämmitys- järjestelmästä, jos lämpöpumppu on asennettu aikaisemmin. 4.
  • Page 59 Kiertovesipumppu (GP1) 3. Asenna letku ja tasotiiviste kiertovesipumppuun 1. Irrota putki kiertovesipumpun (GP1) päällä. (GP1). Letku Tasotiiviste Putki 2. Asenna 2 mukana toimitettua o-rengasta kulmaliit- timen uriin. Liitä kulmaliitin naarasliittimellä varus- tettuun joustoputkeen. Asenna kulmaliitin ja jous- 4. Vedä letku F750:n takasivulle. toputki mukana toimitetulla metallipidikkeellä...
  • Page 60 Täyttöventtiili (QM10) Sähkövastusliitäntä 1. Asenna 2 mukana toimitettua o-rengasta Ø28 mm HUOM! toisen joustoputken liittimen uriin. F750:n täyttöventtiilin vastaventtiili (QM10) pitää poistaa, jotta AHPS:n sisälle ei synny ali- paine. O-renkaat 1. Irrota vastaventtiili täyttöventtiilin (QM10) sisäpuo- lelta. 2. Asenna mukana toimitettu R15-tulppa F750, Kupari Letku 2.
  • Page 61 4-tieliitäntä 1. Irrota puserrusrengasmutteri ja tulppa F750:n 4- tieliitännän paluuputkiliitännästä (XL9). 4-tieliitäntä Puserrusrengasmutteri ja tulppa 2. Asenna mukana toimitettu puserrusrengas liitän- tään (XL9). Puserrusliitin Tukiholkki Mutteri QN32...
  • Page 62 Lisäkäyttöveden putkiliitäntä Periaatekaavio QN10 Vaihtoventtiili, lämmitysjärjestelmä/lämminve- sivaraaja Selvitys QN27 Vaihtoventtiili, lämmitysjärjestelmän kierto AHPS SCA 41 EB100 F750 AA25 Kytkentärasia lisävarustekortilla Lämpötila-anturi, käyttöveden tuotanto, ohjaava Lämpötila-anturi, käyttöveden tuotanto, ohjaava BT63 Lämpötila-anturi, lämmitysvesi meno sähkövas- Lämpötila-anturi, yläkäyttövesi, näyttävä tuksen jälkeen GP31 Venttiiliryhmä, korkean lämpötilan rajoitus Sähkövastus...
  • Page 63 Yleistä Putkiliitännät AHPS Kaksi letkua eristeineen sisältyy SCA 41:n toimitukseen. XL13 XL18 XL46 XL47 XL14 Kaikki muut putkiasennukset tulee tehdä 22 mm put- killa. Vältä jyrkkiä mutkia. MUISTA! Tarpeettomien lämpöhäviöiden välttämiseksi putket tulee eristää. Kylmävesi 1. Asenna sulkuventtiili (QM35), vastaventtiili (RM1) ja T-haara kylmän veden syöttöön.
  • Page 64 Ylempi putkikiinnike Venttiililiitäntä (WP5-GP31) 1. Asenna 3 nippusidettä putkikiinnikkeeseen. 1. Liitä venttiililiitäntä (GP31) käyttövesi- (XL4) ja kyl- mävesiliitäntöihin (XL3) AHPS:ssa (CP1). 2. Asenna 7 nippusidettä pidikkeineen putkikiinnik- keeseen. 2. Ruuvaa kaksi tulppaa (R15). GP31 tulppa 3. Asenna putkikiinnikkeet AHPS:een yläpellin ruuveil- HUOM! 2 o-renkaita ja 1 pidikkeitä...
  • Page 65 Sulkuventtiili WP5-QN32 2. Liitä letku käyttövesiliitännästä (XL4) venttiililiitän- nässä (GP31) kylmävesiliitäntään (XL3) F750:ssa 1. Asenna sulkuventtiili (QN32) AHPS:een (CP1) kuvan (EB100). mukaan. Sulkuventtiili (QN32) Säätömoottori (QN32) EB100-XL9 Ilmausnippa CP1-XL47...
  • Page 66 Shuntti WP5-QN11 Alempi putkikiinnike. 1. Asenna shuntti (QN11) AHPS:een (CP1) kuvan 1. Asenna 4 nippusidettä putkikiinnikkeeseen. mukaan. Shunttiventtiili (QN11) Shunttimoottori (QN11) Kiertovesipumpusta 2. Asenna putkikiinnikkeet AHPS:iin. (EB100-GP1) CP1-XL46 Sähkövastukseen ((EB100-EB1)). CP1-XL18 Ilmausnippa Ilmanpoisto 1. Asenna ilmausnipat kannakkeineen AHPS:een 2 M5x9-ruuvilla.
  • Page 67 Pumppu- ja painehäviökäyrä Oheisessa käyrästössä näkyy pumpun tuotto, kun AHPS on liitetty F750:een. Se korvaa korvaa tässä tapauksessa vastaavan käyrästön F750:n asentajan käsikirjassa. Paine Tryck Tillgängligt externt tryck, klimatsystem med shunt WP5-QN11 öppen Käytettävissä oleva paine, lämmitysjärjestelmä shuntilla WP5-QN11 auki (kPa) (kPa) GP6 läge III...
  • Page 68 Putkiliitäntä, lisälämmönlähde Ulkoisen ja priorisoidun lisälämmönlähteen periaatekaavio Selvitys Ulkoinen lisälämpö Takaiskuventtiili AHPS EB100 F750 SCA 41 AA25 Kytkentärasia lisävarustekortilla Merkinnät standardin IEC 61346 mukaan. Ulkoisen lisälämmönlähteen periaatekaavio - WP5 -AA25 -EB100 -EM2 -EM2-RM2 -WP5-BT52 -CP1 HUOM! Tämä on periaatekaavio. Todellinen laitteisto on suunniteltava voimassaolevien määräysten ja standardien...
  • Page 69 Priorisoitu lisälämmönlähde Kiertovesipumppu, lisälämpö Takaiskuventtiili AHPS EB100 F750 SCA 41 AA25 Kytkentärasia lisävarustekortilla BT52 Lämpötila-anturi, priorisoitu lisälämmönlähde Ei sisälly SCA 41:n toimitukseen. Merkinnät standardin IEC 61346 mukaan. Priorisoidun lisälämmönlähteen periaatekaavio - WP5 -AA25 -EB100 -EM1 -EM1-RM3 -WP5-BT52 -EM1-GP4 -CP1 -FQ1 HUOM! Tämä...
  • Page 70 Yleistä lella AHPS:ssa (CP1). Katso lisäohjeet AHPS:n asentajan käsikirjasta. Lisälämmönlähteen liitäntä AHPS:ään XL46 XL47 AHPS:tta ei tarvitse tyhjentää vedestä ennen SCA 41:n asennusta. 1. Liitä lisälämmönlähteen (EM1) tai (EM2) menoputki T-liittimeen, joka on menoliitännän (XL46) yläpuo- lella AHPS:ssa (CP1). T-liitin...
  • Page 71 Paluuliitäntä aurinko Periaatekaavio Selvitys EP30 Aurinkosarja Kiertovesipumppu, aurinko AHPS EB100 F750 SCA 41 AA25 Kytkentärasia lisävarustekortilla BT53 Lämpötilan anturi, aurinkokeräin BT54 Lämpötila-anturi, aurinkokierukka Merkinnät standardin IEC 61346 mukaan. Periaatekaavio, aurinko - WP5 -AA25 -EB100 -WP5-BT53 -CP1 -EP30 -XL13 -GP4 -WP5-BT54 -XL14 HUOM! Tämä...
  • Page 72 Putkiliitäntä Yleistä Katso AHPS:n asentajan käsikirja. Aurinkokeräimen liitäntä AHPS:een XL13 XL14 AHPS:tta ei tarvitse tyhjentää vedestä ennen SCA 41:n asennusta. 1. Liitäntä menoputki (aurinkokeräimestä) menolii- täntään (XL13). 2. Liitäntä paluuputki (aurinkokeräimeen) paluuliitän- tään (XL14). Tarpeettomien lämpöhäviöiden välttämiseksi putket tulee eristää.
  • Page 73 Lämpöpumpun pitää olla jännitteetön SCA ja rungon väliin. 41:n asennuksen aikana. 5. Asenna etulevy AHPS:ään. HUOM! Jos syöttökaapeli vahingoittuu, sen saa vaihtaa vain NIBE, valmistajan huoltoedustaja tai vas- taava pätevä ammattilainen vaaran välttämi- seksi. Ø 10 mm HUOM! Häiriöiden välttämiseksi ulkoisten liitäntöjen tiedonsiirto- ja/tai anturikaapeleita ei saa asentaa alle 20 cm etäisyydelle vahvavirtakaa-...
  • Page 74 Tiedonsiirron kytkentä Syöttöjännitteen kytkeminen Tämä lisävaruste sisältää lisävarustekortin (AA5), joka Kojerasian (AA25) mukana toimitetaan pistotulpalla kytketään suoraan lämpöpumpun tulokorttiin (liitin varustettu virtajohto (W101, pituus 3,0 m). AA3-X4). Jos olet kytkemässä useita lisävarusteita tai niitä on jo asennettu, sinun täytyy noudattaa alla olevia ohjeita. Ensimmäinen lisävarustekortti asennetaan suoraan lämpöpumpun liittimeen AA3-X4.
  • Page 75 Anturien kytkeminen Aurinkokeräimen lämpötila-anturi (WP5-BT53) asenne- taan lämmönjohtotahnan kanssa ja kiinnitetään nip- Anturi, käyttöveden lataus (WP5-BT6), käyttövesi pusiteillä. huippu (WP5-BT7) ja aurinkokierukka (WP5-BT54) asennetaan anturiputkiinsa AHPS:ssa, katso kuva. Kiinnitä anturikaapelit muovipidikkeillä. Anturi asennetaan aurinkokeräimen anturiputkeen aurinkokeräimen lähtöliitännän vieressä. BT53 BT54 Käytä...
  • Page 76 Kiertovesipumpun kytkentä, priorisoitu lisä- AA5-S2 AA5-X2 AA5-X9 lämpö (EM1-GP4) Kytke kiertovesipumppu (EM1-GP4) liittimeen AA5-X9:2 (230V), X1:1 (N) ja X1:3 (PE) kojerasiassa (WP5-AA25). AA25 Ulkoinen -X10 AA5-X9 AA5-X10 AA5-X1 AA5-X4 Tehdasasennetun kaapelin kytkentä Kojerasiasta (WP5-AA25) lähtevät kaapelit (W104), (W105), (W106), (W107) ja (W108) asennetaan ja kyt- ketään AHPS:een.
  • Page 77 Ulkoisen lisälämmönlähteen kytkeminen Kytke ulkoinen lisälämpö potentiaalivapaan kosketti- men kautta AA7-X2:6:een (N) ja AA7-X2:5 (230 V) kytkentärasiassa (WP5-AA25). AA7-X2 1 2 3 4 5 6 AA25 Ulkoinen Ulkoinen lisälämpö Mahdollisen hätäjäähdytyksen kytkentä Ulkoisen lisälämmönlähteen (EM1), (EM2), (EP30) lämpötilan nousu liian korkeaksi voidaan estää kytke- mällä...
  • Page 78 Käynnistyksen/pysäytyksen, lämpötilojen ja säiliön jäähdytyksen asetus. Valikko 5.3.13.3 - ulkoinen lisälämpö Lisälämmön tyypin valinta ja käynnistyksen asetus. Valikko 3.1 - huoltotiedot Tässä voit nähdä lämpötilan ja onko SCA 41:n mahdol- linen ulkoinen esto aktiivinen. MUISTA! Katso myös F750:n asentajan käsikirja. MUISTA! Lämpöpumpun ohjelmistoversion pitää...
  • Page 79 Sähkökytkentäkaavio...
  • Page 81 Elschema/Wiring diagram/Sähkökytkentäkaavio...
  • Page 84 NIBE AB Sweden Hannabadsvägen 5 Box 14 SE-285 21 Markaryd info@nibe.se www.nibe.eu 331140...