5.3.
SCHEDULED MAINTENANCE TABLE
Maintenance
Daily
Operations
drain condensation
check oil level
clean intake filter
check belt tension
check for oil leaks
check tank for internal
corrosion
Replace air filter
General cleaning of
compressor
Internal & external
inspection of tank
Replace oil
check tube fittings and
electrical connections
check condition of belt
and pulleys
6. TROUBLESHOOTING
Fault
Pressure drop in the tank
Pressure drops when compressor is idle
Safety valve operates below max pressure
Engine and pump run but no air produced
Engine stops and does not restart
Relief valve does not open when max. pressure
is reached, safety valve operates.
compressor does not achieve max. pressure
and overheats
compressor makes metallic rattle
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: no liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
Monthly
3 Monthly
500 hrs.
Air leaks at connections
non-return valve seal defective
Valves leaking or head gasket damaged
Out of fuel or engine fault.
Valve failure or valve incorrectly set
Head gasket or valve fault
Bearing or piston fault
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
5.4.
RECOMMENDED OILS
Recommended oil for compressors, suitable for room
1000 hrs.
temperatures ranging from +5°c to +25°c.
SEALEY cPO or equivalent SAE 40 compressor oil.
Room temperature below +5°c: SAE 20 compressor oil.
Approximate oil capacity: 1.2 litres.
Cause
Brush soap solution over connections and look for
Empty air tank, remove the relief/non-return valve
Faulty valve
check fuel. If OK, contact Authorised Service Agent.
Remedy
Run compressor to max. pressure, switch off.
bubbles. Tighten connections showing leaks.
If problem persists contact Authorised Service
Agent.
(fig.2.B & fig.9) and clean the seat 'd'.
If necessary replace the seal 'E'
contact Authorised Service Agent.
check for leaks, or contact Authorised Service
Agent.
contact Authorised Service Agent.
contact Authorised Service Agent.
contact Authorised Service Agent.
www.sealey.co.uk
01284 757500
Web
sales@sealey.co.uk
01284 703534
email
SA4050/55
Issue: 3 - 06/10/10

Advertisement

loading

This manual is also suitable for: