Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Warning:
instruction
Hot surface
manual
1. SAFETY
1.1.
ELECTRiCAL SAFETY.
WARNiNG! It is the user's responsibility to read, understand and comply with the following:
You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads,
plugs and all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of
appropriate safety devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board. We also
recommend that an RCd (Residual Current device) is used with all electrical products. It is particularly important to use an RCd
together with portable products that are plugged into an electrical supply not protected by an RCCB. If in doubt consult a professional
electrician. You may obtain a Residual Current device by contacting your Sealey dealer. You must also read and understand the
following instructions concerning electrical safety.
1.1.1.
The electricity At Work Act 1989 requires all portable electrical appliances, if used on business premises,
to be tested by a qualified electrician at least once a year, using a Portable Appliance Tester (PAT).
1.1.2.
The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe
condition of the appliance, and the safety of the appliance operator. If in any doubt about electrical safety,
contact a qualified electrician.
1.1.3.
ensure the insulation on all cables and the product itself is safe before connecting
to the mains power supply. See 1.1.1. & 1.1.2. above and use a Portable Appliance Tester (PAT).
1.1.4.
ensure that cables are always protected against short circuit and overload.
1.1.5.
Regularly inspect power supply, leads, plugs and all electrical connections for wear and damage, especially
power connections, to ensure that none are loose.
iMPORTANT: ensure the voltage marked on the product is the same as the power supply to be used, and check that
plugs are fitted with correct capacity fuse.
dO NOT pull or carry the powered appliance by its power supply lead or output cables.
8
dO NOT pull power plugs from sockets by the power cable.
8
dO NOT use worn or damage leads, plugs or connections. Immediately replace or have repaired by a
8
qualified electrician.
1.1.6.
model nos SAC3153B and SAC3203B are supplied with a flying lead without a plug. Jack Sealey limited recommend a 16 amp
protected supply. When connecting to a 16 amp protected supply, contact a qualified electrician to ensure connect to a suitably rated
supply. Provided a good 230V supply is available and the lead length is not increased from that supplied, the compressor may operate
from a 13 amp supply. This very much depends upon the quality of your power supply.
1.1.7.
Wiring a BS 1363/A UK 3 Pin Plug.
WARNiNG! if in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
1.2.
GENERAL SAFETY iNSTRUCTiONS
Familiarise yourself with the application and limitations of the compressor.
9
ensure the compressor is in good order and condition before use. If in any doubt dO NOT use the unit and contact an electrician/service
9
agent.
WARNiNG! Compressor must only be serviced by an authorised agent. dO NOT tamper with, or attempt to adjust, pressure switch or
safety valve.
Before moving, or maintaining the compressor ensure it is unplugged from the mains supply and that the air tank pressure has been
9
vented.
maintain the compressor in good condition and replace any damaged or worn parts. Use genuine parts only. Unauthorised parts may be
9
dangerous and will invalidate your warranty.
Read the instructions relating to any accessory to be used with this compressor. ensure the safe working pressure of any air appliance
9
used exceeds compressors output pressure. If using a spray gun, check that the area selected for spraying is provided with an air change
system/ventilation.
© Jack Sealey limited
COMPRESSOR 150/200ltr BELT dRivE 3.0hp WiTH
FRONT CONTROL PANEL
model no:
Warning:
Wear ear
electricity
protection
Original Language Version
SAC3153B/SAC3203B
Wear eye
Wear protective
protection
clothing
ATiON
SAC3153B/SAC3203B
Warning:
Warning:
Automatic
startup
Recommended Fuse
Rating: 13A
See 1.1.6 for power
supply options
Issue 3 (4, 6) 27/09/18

Advertisement

loading

Summary of Contents for Sealey SAC3153B

  • Page 1 1.1.6. model nos SAC3153B and SAC3203B are supplied with a flying lead without a plug. Jack Sealey limited recommend a 16 amp protected supply. When connecting to a 16 amp protected supply, contact a qualified electrician to ensure connect to a suitably rated supply.
  • Page 2: Specification

    Before using the compressor check the oil level by referring to the oil sight glass (fig.4C). on a horizontal surface, if the oil level is not up to the red centre mark it should be further topped up with recommended oil (See section 5.7). To top up unscrew plug (fig.4B). © Jack Sealey limited Original Language Version...
  • Page 3: Operation

    NOT, other than in an emergency, stop the compressor by switching off the mains power, or by pulling the plug out, as the pressure relief will not then occur and motor damage may result upon restart. © Jack Sealey limited Original Language Version SAC3153B/SAC3203B...
  • Page 4: Maintenance

    Recommended oil for compressors, suitable for room temperatures ranging from +5°C to +25°C. SeAleY CPo or equivalent SAe 40 compressor oil. Room temperature below +5°C: SAe 20 compressor oil. iMPORTANT WARNiNG - Air contaminants taken into the compressor will affect optimum performance. Example: Body filler dust or ‰...
  • Page 5: Troubleshooting

    Warranty: guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. iP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...