LG WFT60A30D Service Manual page 53

Table of Contents

Advertisement

https://appliancetechmanuals.com
(3) Activate/Deactivate Sensor:
Turn the power switch on by pressing WATER LEVEL + PROCESS and START/PAUSE button together.
Test m ode : Only I-SENSOR LED is on and display show s current sensing mode
Current display
: temperature & conductivity sensing is disabled
: temperature sensing is enabled, but conductivity is disabled.
: temperature & conductivity sensing is enabled
1. Press WATER LEVEL BUTTON once:
2. Press PROCESS BUTTON once:
3. Press START/PAUSE BUTTON once:
(4) How to change Controller Group
Turn the power switch on by pressing WATER LEVEL + PROGRAM and Reservation button together.
Init ial Test m ode display : All LEDs are off ,except I-SENSOR LED
Display the number of TR calibration times : Display "
first time and so on.
1. Press Program button once: Display the current Controller Group (1~26)
2. Press START/PAUSE button once : Display the current Controller Group (1~26) (1~26)
The buzzer sounds if there is no controller group.
Press WATER LEVEL BUTTON again : power off
Press PROCESS BUTTON again : power off
Press START/PAUSE BUTTON again : power off
Program button again : Decrease the controller group by one (display the changed group)
Program button to decrease by one
Press START/PAUSE button again : increase the controller group by one (display the changed group)
START/PAUSE button to increase by one
" means not calibrated, "
53
" for the

Hide quick links: