READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
thorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
TYPICAL INSTALLATION
POWER
4" ROUND
CABLE
DAMPER/DUCT
CONNECTOR
CEILING
JOIST
GRILLE
This unit can be installed anywhere between joists
using mounting brackets provided.
INSTALLER: LEAVE THIS
MANUAL WITH THE
HOMEOWNER.
HOMEOWNER: USE AND
CARE INSTRUCTIONS ON
PAGE 3.
Call 1-800-667-8721 anywhere in the US and Canada -
MODEL HS110UE
ULTRA-SENSAIRE
HUMIDITY SENSING
CEILING FAN
PLAN THE INSTALLATION
The location of your
ULTRA-SENSAIRE
very important. Follow
HOUSING
these guidelines for best
operation:
MOUNTING
• The ULTRA-SENSAIRE
BRACKET
FINISHED CEILING
• Locate unit above (GFCI protected circuit required) or within 5 feet of
• Locate unit away from heating or cooling sources which can affect
• Do not locate near window. Unit may respond to the outdoor humidity
• Unit must be installed in ceiling to properly sense moisture.
• Locate unit only on flat ceilings up to 12 feet high for proper sensing.
• The fan will operate most efficiently when located where the shortest
®
WARNING
6. Ducted fans must always be vented to the outdoors.
7. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected
to a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit.
8. Never place a switch where it can be reached from a tub or
shower.
9. This unit must be grounded.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for ceiling installation only.DO NOT
MOUNT THIS PRODUCT IN A WALL.
3. To avoid humidity sensor damage, motor bearing damage
and noisy and/or unbalanced impellers, keep drywall spray,
construction dust, etc. off power unit.
4. Please read specification label on product for further informa-
tion and requirements.
®
fan is
®
fan uses a humidity
sensor that responds to
both increases in humidity
and to humidity levels.
The humidity sensor may
turn the fan ON when
e n v i r o n m e n t a l
conditions change. If the
fan
continuously
responds to changing environmental conditions, "SENSITIVITY"
adjustment may be required.
shower head.
humidity levels.
level.
possible duct run and minimum number of elbows will be needed.
1
www.bathroomsource.com
!
POWER
CABLE

Advertisement

loading
Need help?

Need help?

Do you have a question about the ULTRA-SENSAIRE HS110UE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Broan ULTRA-SENSAIRE HS110UE

  • Page 1 .com bathroomsource www.bathroomsource.com Call 1-800-667-8721 anywhere in the US and Canada - MODEL HS110UE ® ULTRA-SENSAIRE HUMIDITY SENSING CEILING FAN READ AND SAVE THESE INSTRUCTIONS WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 6. Ducted fans must always be vented to the outdoors. INJURY TO PERSONS, OBSERVE THE FOLLOWING: 7.
  • Page 2 PREPARE THE FAN / LIGHT INSTALL THE FAN / LIGHT (CONT'D) FLUSH 1. Remove the screw holding the blower assembly in place. Lift assembly from housing. NOTE: The duct connector has a counter-balanced damper flap. The flap will be "open" approx. 1" when duct connector is attached to housing.
  • Page 3 WIRE THE FAN USE AND CARE (CONT'D) SENSOR OPERATION WIRING OPTION #2 ® The ULTRA-SENSAIRE fan uses a sophisticated humidity sen- Allows fan to operate in automatic mode or to be turned ON sor that responds to: (a) rapid to moderate (user-adjustable) independent of humidity sensing control.
  • Page 4 BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.