The Santa Fe Air Purifier utilizes HEPA-grade Serial Number filtration and UV sterilization capability to clean Install Date your air while also being quieter than a whisper. Sold By Santa-Fe-Products.com Santa Fe Air Purifier Installation & Operation Instructions Santa-Fe-Products.com | 800.533.7533 08/21 Rev A...
REMOVE THE FILTER FROM THE PLASTIC BEFORE USING THE AIR PURIFIER. Thank you for purchasing the innovative KF-P32 air purifier! Follow all safety precautions to ensure proper operation of the device. These instructions describe the safety precautions to be observed during operation. They are designed to prevent injuries or damage to this device.
Page 3
• Do not use this product with an extension cord. • Do not place the air purifier near sources of heat. (e.g.: stove tops, ovens, radiators, or computers) • Unplug the air purifier from the power supply before servicing. • This equipment should be inspected frequently. Any dirt that has collected should be removed regularly to prevent excessive accumulation that may result in flash over or fire. • Do not use the air purifier outdoors or on wet surfaces. • Do not use the air purifier in an enclosed space where flammable, combustible or explosive gases are present. • Do not use in an area where toxic vapors, flammable dust or oxygen tanks are present. • Do not place open flames, including candles, directly in front of the air purifier. • It is important to keep all objects away from the air intake grill. • Place the air purifier on a flat, stable surface. Never place the unit on soft surfaces such as a beds or sofas. • Position the air purifier so that the dirty air is not drawn across your head or body while sitting or sleeping. • Place the air purifier so the plug on the power cord easily reaches a standard electrical outlet. • This product is suitable for use with solid-state speed controls. Santa-Fe-Products.com Santa Fe Air Purifier Installation & Operation Instructions...
Page 4
SAFETY PRECAUTIONS Product Diagram Santa Fe Air Purifier Installation & Operation Instructions Santa-Fe-Products.com...
FEATURES AND OPERATION Instructions for usage Button Icons: Power Speed Medium High Timer Sleep Filter Change Power: When plugged in, the display will turn on for one second and a beep will be heard. The display will read “OFF”, and the air purifier will remain in standby state. Santa-Fe-Products.com Santa Fe Air Purifier Installation & Operation Instructions...
Page 6
Fan Speed >151 High Orange Moderate 150~101 Medium Yellow Good 100~51 Green Very Good <51 Lower Speed: Pressing the “Speed” button will remove the air purifier from Auto Mode. This button allows the user to cycle through fan speeds: low speed, medium speed and high speed. The fan speed cannot be changed during Auto or Sleep modes. Timer: Touching the timer button will cause the display to flash “--H” and “TIMER”. Press and hold the button to set the timer from 1-12 hours. After choosing the desired time, wait two seconds for the display to stop flashing. After 3 seconds the display will show PM2.5 data, indicating setting is done. It calculates by counting down every hour. When the time is up, the air purifier shuts down. Touch the button till icon “--H” or long press the button for 2 seconds to cancel timer setting. UV: Touching the “UV” button turns on the UV sterilization function and lights up the UV symbol. To turn off the UV function press the “UV” button again, the UV symbol should go dark. Sleep: Touching the “Sleep” button will put the air purifier into Sleep Mode. Sleep Mode uses the lowest possible fan speed to create a quite environment. The display and all buttons will turn off leaving only the “Sleep” button lit up at one-third brightness. Touching the sleep button again will return the unit Auto Mode. Santa Fe Air Purifier Installation & Operation Instructions Santa-Fe-Products.com...
Page 7
FEATURES AND OPERATION Display Turn Off Function: Press and hold the “Sleep” button for 2 seconds to turn off the display and buttons, only the “Power” button will be lit at one-third brightness. Touching any button will illuminate the display, at which point the buttons will function as usual. After 15 seconds without any operation, the display will turn off again. Press and hold the “Sleep” button to exit display turn off function. Filter Change When air purifier reaches 3,000 working hours, the filter change indicator icon in the display will flash red to remind user change filter until the filter is changed. After filter is changed, in standby mode, press the “Speed” button two times, then hold this button for 2 seconds, filter change indicator icon will flash quickly. Five seconds later the whole display flashes for a second and then turn off to enter in standby mode indicating the filter change is complete. Now, touch “Power” button to switch on the air purifier. Note: 3,000 hours is calculated based on low speed. It will remind filter change less than 3,000 hours if the air purifier works in other speeds. Protection The air purifier has a protection function. When the filter cover is removed or not installed well, the air purifier will automatic cut off. Maintenance After using the air purifier for an extended period, dust on the sensor will affect its sensitivity. We suggest cleaning the unit every two months. But time can be shortened or extended according to indoor environment. Santa-Fe-Products.com Santa Fe Air Purifier Installation & Operation Instructions...
Page 8
FEATURES AND OPERATION How to clean the dust sensor Unplug then open the dust sensor cover and clean with a wet cotton swab. Then dry the lens with a new, dry cotton swab. Santa Fe Air Purifier Installation & Operation Instructions Santa-Fe-Products.com...
TROUBLESHOOTING If your air purifier is not working correctly, please check the table below. Problem Possible Reasons Solution No Power Fault in power source Switch on when the power source gets regular Plug improperly connected Unplug the unit and plug in again Not Working Fault in electrical circuit Try using the unit at a different outlet There may be a foreign object in the air purifier Take to service center Unusual Noise Dirty filter Replace the filter The filter plastic bag was not removed Remove bag from the filter Technical Specifications Input voltage: AC 120V Frequency: 60Hz Consumption power: 40W Applicable area: 46m² Noise level: ≤55dB CADR: 230CFM (390m³/H) Operating condition: Temperature: 10°~45° Humidity: ≤95%RH Santa-Fe-Products.com Santa Fe Air Purifier Installation & Operation Instructions...
We guarantee the unit TO BE free from defects in material or workmanship for a period of one (1) year from the date of purchase. Should this unit be operated under conditions other than those recommended or at voltages other than the voltage indicated on the unit, or any attempts made to service or modify the unit, this will render WARRANTY VOID. The product you buy may sometimes differ slightly from illustration. DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. Santa Fe Air Purifier Installation & Operation Instructions Santa-Fe-Products.com...