Page 2
If the instructions are not followed, the protection provided by the meter may be destroyed. Trademark, Copyright and Restriction Instructions Dandong Top Electronics Instrument (Group) Co.,Ltd.®, Dandong Top Pump Co., Ltd.®, DDTOP® are registered trademarks of the company. The performance specifications of the meter are effective as of the date of publication and are subject to change without notice.
9.1 How to Identify Fluid Flow in a Pipeline ..................... 12 9.2 How to Set up a Zero Cut to Avoid Invalid Accumulation ............12 9.3 How to Set 4~20mA Output ........................12 Appendix Common Parameters........................12 WWW.DDTOP.COM 3 / 15...
The operations described in this manual are performed by professionally trained and qualified professionals or end-user specialized professionals to complete. 2 Product Description 2.1 Main Structure of the Product - Figure 1 Ultrasonic Flow Meter UFM-C October 10,2019 18:18:18 Instantaneous Flow Rate: 123.45 Accumulation:...
4.2.1 Check the appearance of the instrument for defects, damage and other abnormalities. 4.2.2 Checking for damage, fracture and other abnormalities in the straight pipe section. 4.2.3 Checking for abnormalities such as untightened sensor cover plate connections. 5 Screen and Operation WWW.DDTOP.COM 5 / 15...
(settings) interface; press the return key (ESC, that is, the middle of the two buttons) will return up to the first level of the menu, and finally return to the main WWW.DDTOP.COM 6 / 15...
Figure 5 Outer Diameter Edit Box 2) Press to select "Pipe Wall Thickness", press to enter the wall thickness edit box, type the wall thickness value, press to save and return to the previous menu. Figure 6 Wall Thickness Edit Box WWW.DDTOP.COM 7 / 15...
Page 8
5) Press to select "lining thickness", press to enter the lining thickness edit box, if there is no lining material, enter 0, press to save and return to the upper level menu, if there is a lining WWW.DDTOP.COM 8 / 15...
Enter the first level menu "4. Flow Rate Setting", you can set the resolution and multiplication factor of instantaneous flow rate, the resolution and multiplication factor of accumulation rate, and the display mode of accumulation rate as shown in Figure 12. WWW.DDTOP.COM 9 / 15...
"Single-point Calibration", i.e. press the down arrow to select the corresponding mode, and then enter the corresponding position in the lower level menu. Two or more sets of measurements and standard values. WWW.DDTOP.COM 10 / 15...
Chapter 3, and install the flow meter. 8.4 Factory Setting This menu item is a design-developer specific menu and cannot be set by the user. WWW.DDTOP.COM 11 / 15...