6.
DONNING THE APPARATUS
WARNING: Only when the equipment is donned and worn correctly as described below will it provide the prescribed protection.
6.1.
Fasten belt around the waist with the preset regulator situated above the right hip.
6.2.
Place the mask on the head and check height setting. Ensure head band is not too low on the brow. If necessary adjust crown
strap until correct height adjustment is achieved. With mask on head turn adjuster knob to obtain a firm and comfortable fit.
Any condensation must be removed before donning the mask.
6.3.
Connect compressed air supply tube to the preset regulator. If vibration occurs upon connection, decouple and slowly re-connect.
6.4.
Connect the spray gun tube to the supply tube if required.
6.5.
When walking, the trailing leader tube should be grasped firmly in one hand to prevent the tube connector, or the preset
regulator from being pulled.
6.6.
See HSE Practical Guide for users of respiratory protective equipment.
7.
MAINTENANCE & SERVICE
Under COSHH regulations the equipment must be checked at monthly intervals (use a record card). Care taken during and after use will
ensure that the equipment gives reliable and lasting service.
The system is designed to minimise servicing. Worn or damaged components can be replaced as sub-assemblies (see parts list).
7.1.
Cleaning
The apparatus should be washed with a mild soap solution, wiped clean with a clean damp cloth and allow to dry.
Rinse the mask with a mild detergent in tap water (see 7.3) and dry with a soft clean cloth.
IMPORTANT: DO NOT USE SOLVENTS OR ABRASIVES as they will damage the equipment. See 7.3. for recommended cleaning agents.
7.2.
General Maintenance.
7.2.1.
Preset Regulator
This regulator is preset and sealed and can only be replaced as a complete unit.
7.2.2.
Belt Mounted Filter Unit
The unit has a replacement element (Item 8) contained in a screw on/off bowl housing. This element must be replaced if its colour
changes from white to pink, or if there is any trace of odour. It is suggested that the filter unit is periodically subjected to a pressure
differential test at full flow. If a 10psi differential is recorded then the filter requires replacing. To do so, disconnected the air supply,
unscrew the element, clean the bowl with soapy water and thoroughly dry. Screw new element on (hand tight only) and check
for leaks. If the bowl is scratched, pitted or discoloured, fit a new bowl (item 9). Fit bowl hand tight only, and check for any leaks.
WARNING!: DO NOT hand wash or brush filter to reclaim for further use. Check flow indicator (parts list item 18) for damage.
7.2.3.
Coalescing Filter
The unit has a screw on/off bowl housing the replaceable element. The element must be replaced if there is more than 10psi
pressure differential, or the element has become saturated. To do so, disconnected air supply, unscrew bowl, unscrew the element
and discard. Fit new element by screwing hand-tight only and check for leaks. The bowl should be cleaned with soapy water
and thoroughly dried before replacing. If the bowl is scratched, pitted, or discoloured fit a new bowl.
WARNING!: DO NOT attempt to reclaim the filter for further use, either by hand washing or brushing.
7. 3.
Recommended Cleaning Agents.
a) Mild soap solution i.e. Fairy Liquid, manufactured by Lever Brothers.
b) Holts anti-static cloth “Screenies” for goggle or visor protection.
c) Suitable disinfectant such as manufactured by T.H.Goldsmith, Eastcote, Middlesex.
8.
DECLARATION OF COMFORMITY
Declaration of Conformity We, the sole UK importer, declare that the products listed below are in conformity with the
following standards and directives.
Complete Air-Fed Breathing System
Models: SSP200 & SSP200K
BSEN270 APF40 IMPACT EN 166.F
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
The construction files for these products are held by the Manufacturer
and may be inspected, by a national authority, upon request to
Jack Sealey Ltd.
Signed by Mark Sweetman
For Jack Sealey Ltd. Sole UK distributor of Sealey Safety Products.
Sole UK Distributor,
Sealey Group,
Bury St. Edmunds, Suffolk.
01284 703534
E-mail: sales@sealey.co.uk
SSP200 & SSP200K - 0738 - (2) - 020801
2nd August 2001