Download Print this page

Advertisement

Quick Links

Thank you for purchasing a Sealey Power Product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT
BEFORE USING THIS PRODUCT, PLEASE READ THE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS,
WARNINGS AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE, FOR THE PURPOSE FOR WHICH IT IS INTENDED.
FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
(The use of symbols in this document is to attract your attention to possible danger, and reminders, the symbols and warnings themselves do not eliminate any danger, nor are they
substitutes for proper accident prevention measures).
The SSP200 is the Full Face Mask and Belt assembly only, which must be used in conjunction with coalescing filter SSP21X
and low toxic breathing hose SSP20H to provide clean air to BS4275. The SSP200 is the complete air-fed full face mask system
(see parts list). All further references relate to the SSP200K complete kit.
1. WARNINGS
1.1. General
! The SSP200K Complete Air Kit system is NOT designed for use in atmospheres containing flammable gas mixtures.
! The SSP200K is designed for use against contaminants which are NOT immediately dangerous to life and health or where self contained
breathing apparatus is not essential.
! SSP200K is designed for use with
! No protection is given unless the mask is correctly fitted and an adequate supply of breathing air is maintained.
! Only when the equipment is correctly donned, and worn, will it provide the prescribed degree of protection.
! The SSP200K is the correct apparatus for persons with a beard or facial hair. DO NOT use a half mask.
! A combination of wall mounted filter SSP21X and belt mounted carbon filter unit WILL NOT remove Carbon Monoxide, Carbon Dioxide,
or other toxic gases. Wall mounted filter SSP21X is designed to squeeze out particulate and moisture from the air supply.
! If you are in any doubt as to the suitability of the equipment for the work to be undertaken, consult your supplier.
1.2. Negative Pressure
! At high work rates you may experience air pressure within the mask being momentarily “NEGATIVE” as the user breathes in.
! The apparatus has a maximum flow of 232 ltr/min and must not be used where work rate will require a supply in excess of 232 ltr/min.
1.3. Compressed Air Supply
! The user MUST ensure that the air supply range to the apparatus is within the limits recommended.
! If air supply ceases, or is significantly reduced, immediately withdraw from contaminated atmosphere and check system for faults.
2.
INTRODUCTION
The SSP200 & SSP200K are part of a range of compressed air equipment with a variety of head pieces for use in atmospheres which
include paint spray, toxic dusts, mists and fumes but where life supporting respiratory equipment IS NOT ESSENTIAL.
The SSP200 & SSP200K have been tested, approved and certified to BSEN270. They are designed to give maximum working life from the
major components coupled with rapid and economic exchange of those parts most susceptible to wear and tear.
A comprehensive range of parts and accessories is available to ensure that the kit can always be used in the recommended manner.
Note: The use of improper parts and accessories may be dangerous and will invalidate the warranty.
2.1. System Description - SSP200K
The system comprises a lightweight mask connected via a breathing hose to a pre-set regulator, with flow indicator and spare carbon filter,
mounted on a comfortable waist belt with quick release buckle. The hose kit consists of a compressed air supply tube and couplings, fitted
with a “Y” piece which connects to the pre-set regulator. A 1.5 metre compressed air supply tube is provided for connection of a spray gun.
Upon receipt of the equipment, check parts against the parts list and ensure that all is in good condition. If you experience any problem
contact your supplier immediately.
2.2. Technical Specification
Nominal Protection Factor
Air Supply Pressure
Max Hose Length (supply to regulator)
Mask Air Supply Rate
INSTRUCTIONS FOR:
COMPLETE AIR-FED BREATHING SYSTEM
Models:
COMPRESSED AIR ONLY. DO NOT USE WITH COMPRESSED OXYGEN OR OXYGEN ENRICHED AIR.
200
Max 10bar (145psi)
Min 4bar (60psi)
15m
Max 232ltr/min
Min 160ltr/min
SSP200 & SSP200K
Environmental Working Temperature
Nominal Actual Filter Life
Mask Air Supply Rate
1.5-50
C
0
400 operating hours
(approx. 2 months)
EN166.F
SSP200 & SSP200K - 0738 - (2) - 020801

Advertisement

loading

Summary of Contents for Sealey SSP200

  • Page 1 INTRODUCTION The SSP200 & SSP200K are part of a range of compressed air equipment with a variety of head pieces for use in atmospheres which include paint spray, toxic dusts, mists and fumes but where life supporting respiratory equipment IS NOT ESSENTIAL.
  • Page 2 If, upon re-test, the indicator is still within either red section, the apparatus should not be used without a complete examination of the equipment and air supply followed by a further re-test. SSP200 & SSP200K - 0738 - (2) - 020801...
  • Page 3 BSEN270 APF40 IMPACT EN 166.F For Jack Sealey Ltd. Sole UK distributor of Sealey Safety Products. NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

This manual is also suitable for:

Ssp200k