1.0 GENERAL INFORMATION
This manual shows you how to safely install, operate and use the device.
The instructions for use ALWAYS need to be available in the facility where the device is installed.
ATTENTION: installation/maintenance needs to be carried out by qualified staff (as explained in
section 1.3) by using suitable personal protective equipment (PPE).
For any information pertaining to installation/maintenance or in case of problems that cannot be solved with the instructions,
contact the manufacturer by using the address and phone numbers provided on the last page.
1.1 DESCRIPTION
A device that retains dust particles conveyed by the gas and protects the elements in danger (burners, counters, boilers,
pressure regulators, etc.) from rapid clogging.
IT consists of a filter cartridge made of washable synthetic material and can be entirely removed for full inspection, cleaning
and/or replacement.
It can be supplied equipped with:
• pressure test nipples and/or connections to control the pressure and/or differential pressure.
• cap or drain valve for condensation drainage.
• clogging indicator differential pressure gauge installation set-up;
• pressure gauge already installed.
Reference standards: EN 126 – EN 13611.
1.2 KEY TO SYMBOLS
DANGER: Failure to
observe this may cause
damage
to
goods.
1.3 QUALIFIED STAFF
These are people who:
• Are familiar with product installation, assembly, start-up and maintenance;
• Know the regulations in force in the region or country pertaining to installation and safety;
• Have first-aid training.
1.4 USING NON ORIGINAL SPARE PARTS
• To perform maintenance or change spare parts (e.g. filter element, O-ring, etc.) ONLY USE manufacturer-recommended
parts. Using different parts not only voids the product warranty, it could compromise correct operation of the device.
• The manufacturer is not liable for malfunctions caused by unauthorised tampering or use of non-original spare parts.
1.5 IMPROPER USE
• The product must only be used for the purpose it was built for.
• It is not allowed to use fluids other than those expressly stated.
• The technical data set forth on the rating plate must not, under any circumstances, be exceeded. The end user or installer
is in charge of implementing proper systems to protect the device, which ensure the maximum pressure indicated on the
rating plate is not exceeded.
• The manufacturer is not responsible for any damage caused by improper use of the device.
Madas Technical Manual - 6|6.3 - REV. 0 of 1
DANGER: Failure to observe this may
cause damage to tangible goods, injury
tangible
to people and/or pets.
th
Oct 2018
ATTENTION: Attention
is drawn to the technical
details
intended
for
qualified staff.
FM

Advertisement

loading

Summary of Contents for Madas DH65-150

  • Page 1 • The manufacturer is not responsible for any damage caused by improper use of the device. Madas Technical Manual - 6|6.3 - REV. 0 of 1 Oct 2018...
  • Page 2: Technical Data

    • Insert the relative washers inside the bolts in order to prevent damage to the flanges during tightening; • When tightening, be careful not to “pinch” or damage the gasket; Madas Technical Manual - 6|6.3 - REV. 0 of 1 Oct 2018 ¡...
  • Page 3 11. SM remote jerk ON/OFF valve lever control 6. MVS/1 relief valve 12. Expansion joint/anti-vibration mount " & & £ £ £ £ ¤ ¨ © £ ¤ ¥ ¦ § Madas Technical Manual - 6|6.3 - REV. 0 of 1 Oct 2018 ¡ ¡...
  • Page 4: First Start-Up

    • At the end of its service life, the product is to be disposed of in compliance with the legislation in force in the country where this operation is performed. Madas Technical Manual - 6|6.3 - REV. 0 of 1 Oct 2018...
  • Page 5: Warranty

    • Follow the same procedure in the diagrams on pages 32 and 33 to calculate the pressure drop of the filters to the various filtering points (50 µm -20 µm -10 µm). Madas Technical Manual - 6|6.3 - REV. 0 of 1 Oct 2018...
  • Page 6 Proximity sensor features • Maximum voltage: 30 Vdc • Maximum power: 100 mA • Protection degree: IP55 • Protection way: EEx ia IIC T6 • Cable length: 2 m Madas Technical Manual - 6|6.3 - REV. 0 of 1 Oct 2018...