TWO YEAR WARRANTY
Any Cito Warm Water Thaw Device found to be defective
in material or workmanship within 2 years from date of
purchase will be repaired or replaced free of charge,
when shipped prepaid to the factory. Warranty does not
include breakage of the thermos liner.
Note: Model AI-CT-120 and AI-CT-240 do not
use with a portable Generators.
Keep Electrical Connections Clean and Dry
SHIPPING INSTRUCTIONS
Package to avoid damage, label
FRAGILE - GLASS
and ship to:
N8779 COUNTY ROAD X
WATERTOWN, WI 53094 U.S.A.
TEL: (920) 261-6646
www.citoai.com
TO OPERATE
1. Fill Cito Thaw with clean tap water. Plug
cord into correct voltage source as indicated
on base of unit. Wait for thaw device to heat
up to proper temperature. Your water temper-
ature when you started determines the exact
warm up time approximately 2
minute.
50
O
water temp. to 96.8
60
O
water temp. to 96.8
70
O
water temp. to 96.8
80
O
water temp. to 96.8
2. Green ready light must be on, indicating
unit is up to temperature.
3. Agitate the water by taking the basket and
moving it up and down several times to assure
water temperature is consistent through the
water bath.
P.O. BOX 90
FAX: (920) 261-1350
sales@citoai.com
CT-I-4-C-1-10K
O
F/1.1
O
C per
O
F/36
O
C = approx. 23 min.
O
F/36
O
C = approx. 18 min.
O
F/36
O
C = approx. 13 min.
O
F/36
O
C = approx. 8 min.
INSTRUCTION MANUAL
96.8
AI-CT-12-F
CITO THAW 12VDC - F TEMP. READ OUT
AI-CT-12-C
CITO THAW 12VDC - C TEMP. READ OUT
AI-CT-120-F
CITO THAW 12VDC-120VAC - F READ OUT
AI-CT-240-C
CITO THAW 12VDC-240VAC - C READ OUT
12V Cord
(lighter plug)
Power Supply Cord
Thank you for selecting the Cito Thaw. This
electronic device automatically heats and
maintains an accurate water temperature.
Cito Thaw was designed to give you years of
trouble free service.
PROCEDURE TO CHECK WATER TEMP.
Place THAW MONITOR in water for a minimum
of 10 seconds. See instructions on back of
THAW MONITOR to determine temperature of
water bath.
4. With the correct water temperature you are
now ready to thaw semen in your Cito Thaw.
5. NOTE: New Cito Thaw units have an internal
temperature adjustment knob. Your Cito Thaw
has been factory calibrated to 96.8
However, if you desire to change the preset
temperature, you may readjust it by removing
the 7 screws on the bottom of the unit and
adjusting the knob clockwise for warmer and
counter-clockwise for cooler temperatures. Turn
temperature adjustment knob a little at a time
and allow unit to stabilize before checking
temperature again.
6. If unit does not maintain proper temperature,
return unit for repair or replacement. Ship to
factory with your comments and your address.
THAW
F / 36
C
O
O
120V Cord
240V Cord
O
F/36
O
C.

Advertisement

loading
Need help?

Need help?

Do you have a question about the AI-CT-12-F and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for CITO AI-CT-12-F

  • Page 1 THAW TWO YEAR WARRANTY Any Cito Warm Water Thaw Device found to be defective INSTRUCTION MANUAL in material or workmanship within 2 years from date of purchase will be repaired or replaced free of charge, 96.8 F / 36 when shipped prepaid to the factory. Warranty does not AI-CT-12-F CITO THAW 12VDC - F TEMP.
  • Page 2 THAW TWO YEAR WARRANTY Any Cito Warm Water Thaw Device found to be defective INSTRUCTION MANUAL in material or workmanship within 2 years from date of purchase will be repaired or replaced free of charge, 96.8...

This manual is also suitable for:

Ai-ct-12-cAi-ct-120-fAi-ct-240-c