  • Page 1 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC...
  • Page 2: Table Of Contents

    Victoria-05 Ltd. CONTENTS INTRODUCTION................................... 3 SAFETY INFORMATION................................ 3 TECHNICAL DATA AND DIMENSIONS........................... 4 SAFETY DEVICES.................................. 6 ELECTRICAL WIRING DIAGRAM............................6 COMPONENTS..................................7 OPERATING MODE................................7 FUEL....................................8 APPLIANCE INSTALLATION..............................8 10. APPLIANCE OPERATION...............................11 10.1.
  • Page 3: Introduction

    03.2019 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC 1. Introduction. We congratulate you on the excellent choice! Do not leave this instruction manual unread. Installation and operation of a pellet boiler associated with various legal obligations, which are explained in this instruction manual. According to the laws and regulations for safe use of appliances of this class, the purchaser and user of the pellet boiler undertake using this instruction manual to inform themselves for the assembling and the right operation of the appliance.
  • Page 4: Technical Data And Dimensions

    Victoria-05 Ltd. • Rating label is placed on the back of the pellet boiler. • Keep this instruction manual, warranty card and purchase invoice in good condition, as will be necessary in any inquiries. After shut down, do not burn the pellet boiler again before cleaning the combustion chamber! Removed pellets from the combustion chamber should not be placed back in the pellet fuel hopper! 3.
  • Page 5 03.2019 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC Technical data and performance: Performance: Technical data Classic 16.5 Classic 22 Pellet boiler class Nominal heat output 16.57 kW 21.80 kW Reduced heat output 8.05 kW 6.70 kW Operating water pressure 1.5 bar...
  • Page 6: Safety Devices

    Victoria-05 Ltd. We reserve the right to make changes in products without prior notice, in order to improve their performance. 4. Safety devices. Fume thermocouple: It is placed at the top part of the heat exchanger to measure the temperature of the flue gasses.
  • Page 7: Components

    6. Components. Ignition: Performs ignition of the pellets.. Fume extractor: Extracts the flue gases from the combustion chamber to the flue pipes and sucks in fresh combustion air by means of vacuum. Gear motor: Driven auger screw by means of which the pellets are conveyed from the pellet fuel hopper to the combustion chamber. Circulation pump: Provides forced circulation of the fluid in the heating system.
  • Page 8: Fuel

    Victoria-05 Ltd. High efficiency and low emission of the pellet boiler is guaranteed by an electronic control system that manage the amount of fuel, the flue gases conduction, supplying of combustion air and operation of the circulating pump. The control panel of the control system is placed in front of the upper panel of the pellet boiler (G) in Figure 2.
  • Page 9 03.2019 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC Safe distances for fire safety: When installing a pellet boiler and storage of wood pellets, must be respected the fire safety requirements! It is recommended that an appropriate place to mount a fire extinguisher.
  • Page 10 Victoria-05 Ltd. Fig.4. А - Insulated metal chimney. В - Minimum height of 1.5 meters beyond the eaves of the roof. С - Incoming outside air through the section with minimum cross section of 80 сm Е - Incoming outside air through the section with minimum cross section of 80 cm.
  • Page 11: Appliance Operation

    03.2019 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC Consider adding fluids against freezing and corrosion. Use softener, if water in the system has the values of hardness higher than 19 dH. Technician who has installed the pellet boiler should provide suitable expansion vessel, depending on the type of system that the device will serve.
  • Page 12: Control Panel Description

    Victoria-05 Ltd. 10.2. Control panel description. Onto the display can be seen a good amount of information, which is displayed via graphic symbols and text. Current Time – hour and date Accumulated emergency alarms or computer connection Heat Exchanger Water Temperature...
  • Page 13 03.2019 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC Main Screen: Time Process Data Time 11:25 15.03.2015 Water Temperature 23°C Status Heating system preset temperature Ready 80°C Timer Current indoor temperature 24°C Pump Alarm 10.2.1. Operation Modes: The user is provided with the possibility to edit the operation menu of the pellet boiler.
  • Page 14 Victoria-05 Ltd. <Feed> In the feed mode the feeding screw is operating (the feed time is set with a parameter * In this mode the feeding is done in cycles to reach smooth distribution of the pellets in the fuel pot.
  • Page 15 03.2019 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC <Stop> Mode On holding the „Start/Stop” button controlled extinction of the pellet boiler. *the fan and the feed screw operate with parameters as in P3 Modulation Mode; To transfer to <Stop> Mode there are three options: Press and hold Start/Stop button for 3 sec.
  • Page 16 Victoria-05 Ltd. 10.2.3. Menu Structure Operation mode Режим на работа Temperature Air correction Корекция въздух Boiler temperature Pellets correction Лимит на мощност Hysteresis Power limit Температури Indoor temperature Temperatures Стаен термостат Indoor temp. hysteresis Room thermostat Current values 60̊ С...
  • Page 17 03.2019 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC Отложен старт Delayed start Clock/Timer 01.01.2019 Delayed start 01.01.2019 15:31:36 Weekly timer 15:31:36 Date/time Clock/Timer Weekly timer Delayed start Status Status Weekly timer To program Date/time 012345678901789 Sun………………… Mon…………………...
  • Page 18 Victoria-05 Ltd. 10.2.3. Installer Menu Factory Settings: Passwd **** Classic Classic 22 16,5 KW Ignition Duration 900 sec. 900 sec 210 % 210 % Initial Feed 70 sec 70 sec Ignition Feed Screw Duration 2 sec 2 sec Fan %...
  • Page 19: Instruction Manual

    03.2019 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC Clean Initial Clean 60 sec 60 sec Clean Extinction 600 sec 600 sec Initial Clean Clean time Extinction Clean time Clean period Clean period External clean External clean Temperatures Boiler Temperature 40 :С...
  • Page 20: Daily Cleaning

    Victoria-05 Ltd. To operate properly, the pellet boiler must be regularly serviced. 12.1. Daily cleaning. For better heat transfer and reduce fuel consumption, its need daily cleaning of the soot in flue channels. While pellet boiler works, open the top door and by energetic movements move up / down of the cleaning elements through the handle (Figure 6).
  • Page 21: Maintenance And Control

    03.2019 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC - Clean propulsion parts and electric motors. Make sure there are no gaps; - Clean the flue channels and chamber of fume extractor; - Clean and check the circulation pump;...
  • Page 22 Victoria-05 Ltd. А02 – Pressure Sensor Fault May occur on faulty sensor or Fault in the pressure sensor. Change the sensor faulty control unit. Change the control unit А03 – Water Temp. Sensor Fault May occur on faulty water Faulty temperature sensor - Procedure to implement by a temperature sensor.
  • Page 23: Checklist

    03.2019 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC 14. CHECKLIST. Location and installation: Ventilation of the room; Only the flue outlet of the pellet boiler is connected to the chimney; Connecting flues pipes have a horizontal section with a length of max. 2 m, minimum slope of 3%, not more than two curves at 90°...
  • Page 24 Victoria-05 Ltd. Can you use other types of fuel than wood pellets? NO. Pellet boiler is designed to work with wood pellets with a diameter of Ø 6 mm. The use of another type of fuel leads to damage.
  • Page 25 03.2019 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC...
  • Page 26 Victoria-05 Ltd.
  • Page 27: Product Fiche

    03.2019 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC PRODUCT FICHE 1. Supplier's name or trademark. Victoria-05 Ltd. 61A Anton Strashimirov Str. 5100 Gorna Oryahovitsa Republic of Bulgaria Phone: +359 618 60282 Fax: +359 618 60200 E-mail: info@v05.bg http://www.v05.bg...
  • Page 28: Product Fiche

    Phone: +359 618 60282 Fax: +359 618 60200 E-mail: info@v05.bg http://www.v05.bg 2. Supplier's model identifier. Pellet boiler CLASSIC 22 3. Energy efficiency class. А+ 4. Rated heat output. 21 kW 5. Energy efficiency index. 6. Seasonal space heating energy efficiency.
  • Page 29: Spare Parts Catalogue

    03.2019 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC SPARE PARTS CATALOGUE № Appellation Gear motor for auger Fume extractor ST25, aluminum volute Ø150, encoder (set) Auger (set) Ignition Thermostat Electronic control system (set) Control panel Circulation pump...
  • Page 30: Warranty Conditions

    Failing that provided, the claim is not accepted as valid and the buyer pays repair. On the territory of Bulgaria the term of the removal of the claim is up to three (3) days for settlements in which Victoria-05 Ltd.
  • Page 31: Diary

    03.2019 INSTRUCTION MANUAL for installation and operation of pellet boiler CLASSIC DIARY for repairs under warranty № Company Receipt date Type of repair Delivery date Carried out...
  • Page 32 Victoria-05 Ltd. Victoria-05 Ltd. 1B Ivan Momchilov Str. 5100 Gorna Oryahovitsa Republic of Bulgaria phone: +359 618 60282 fax: +359 618 60200 e-mail: info@v05.bg http://www.v05.bg...

Table of Contents