Mains voltage selection / fuse replacement
The following work should only be carried out by a qualified
!
technician in accordance to highest electrical safety standards.
Risk of electric shock.
Replacing the fuse
The fuse must be replaced by a 0.63AT type (5x20mm). Never
attempt to short the fuse holder. Normally the fuse should never
blow – if it has, it is a sign of a serious fault condition. Further
investigation is needed.
Mains voltage
Altering the mains input voltage range from 115V to 230V or vice
versa is done by changing the fuses according to the figure 3
below. You will need 1x 0,63AT for 230 V operation and 2x 0,63AT for
115V
operation.
Never
attempt
to
apply
any
other
fuse
configuration or a short circuit condition will occur.
(Figure 3)