  • Page 1 – Twin 4XL NL I nstallation and user manual...
  • Page 2 EXTERIOR...
  • Page 3 INTERIOR 335 mm...
  • Page 5 Please keep this manual for future reference. Though these operating instructions have been compiled with the greatest possible care, they are subject to change and improvement. For the most recent version, please refer to https://alfen.com/ nl/downloads...
  • Page 6: Table Of Contents

    Mr. M. Roeleveld Managing director 5. Connectivity 5.1 Backoffice management systems 20 5.2 Establishing a connection 5.2.1 Wireless connection 5.3 Registering your charging station within your own backoffice management system Twin 4XL NL manual | Version 4.3 | September 2021...
  • Page 7: Safety And Usage Instructions

    1. SAFETY AND USAGE INSTRUCTIONS 1.1 Purpose and intended audience In the following cases, Alfen ICU B.V. shall not be liable in The Alfen Twin 4XL charging station is intended exclusively any way for any kind of damage and all warranties on the...
  • Page 8: Product

    Identification label with identification number of the charging station (see description under the heading "Identification label") On/off switch 4-pole (see Figure 2 for detailed location) Fig. 3: Example of an identification label Twin 4XL NL manual | Version 4.3 | September 2021...
  • Page 9: Status Indications On The Interface

    LEDs to provide status indications of the charging station, and inform the user about starting and stopping the charging process. Fig. 4: Display of Twin 4XL NL during charging (charging point left) Status and information interface; The charging station informs the user of its current status and provides the user with a response to actions performed.
  • Page 10: Operation

    2. PRODUCT 2.3 Operation Plug & Charge – General authorization without charge card Start Stop RFID – Charging station with user authorization Start Stop Twin 4XL NL manual | Version 4.3 | September 2021...
  • Page 11: Technical Specifications Twin 4Xl Nl

    TT system (Earthing facilities are always the responsibility of the owner of the loading object). Main switch Four-pole, 80 A, 400 V Connection in the distribution system operator connection box (934452501 and 934452504) Twin 4XL NL manual | Version 4.3 | September 2021...
  • Page 12: Output/ Vehicle Supply

    4G: LTE Cat M1 bands: 3, 8, 20 Communication OCPP 1.5 (JSON) protocol OCPP 1.6 (JSON) 2nd edition, certified OCPP 2.0 (JSON) Backend connection ICU Connect (optional) or other management system (upon request) Twin 4XL NL manual | Version 4.3 | September 2021...
  • Page 13: Operating Conditions

    Standard key for door operation included in delivery Dimensions (H x W x D) Casing 1385 x 335 x 220 mm Packaging 1400 x 350 x 300 mm Weight Casing Approx. 40 kg Packaging Approx. 2.5 kg Twin 4XL NL manual | Version 4.3 | September 2021...
  • Page 14: Optional Factory Settings

    Dimensions (H x W x D) 598 x 204 x 300 Weight 7.8 kg Packaging (H x W x D) 50 x 295 x 620 Extra RFID card Art. 203120010-ICU Twin 4XL NL manual | Version 4.3 | September 2021...
  • Page 15 1x Wiska stuffing box M12x1.5 1x Connection nut 12 M12x1.5 1x Cable entry gasket 3x Grommet for ethernet cable 1x Grommet for ground cable 2x Grommet for Smart Charging Network 1x Bottom seal Twin 4XL NL manual | Version 4.3 | September 2021...
  • Page 16: Assembly And Connecting

    Prevent pedestrians from tripping over cables REMARK 3.3 Mechanical installation Wear the prescribed personal protective equipment (PPE) Use the following tools and materials to install the Twin 4XL NL: when working. Take national and local standards and • Level, Shovel, Stanley knife regulations into account.
  • Page 17 Open the lock with the key(s) provided, or the passkey provided, if no cylinders are installed; e. Lever can be pulled out; f. Turn the lever counter-clockwise to open the door Twin 4XL NL manual | Version 4.3 | September 2021...
  • Page 18: Electrical Installation

    WARNING See figure 6. c. Tilt the Twin 4XL NL, which has been laid out on the Always attach a good earth conductor first back above the base, onto the base over the wire ends and over the power supply cable and ground cable.
  • Page 19: Commissioning The Charging Station

    'IN- (1) status; use a special key to make switching easier; For types with a house connection box, place any Close the Twin 4XL NL by clicking the door into the cartridges supplied in the cartridge holders and close lock.
  • Page 20: Connectivity

    GPRS (SIM card) or a the right type of charging point. UTP (Ethernet) cable. Each model Twin 4XL NL has its own so-called Charge Point 5.2 Setting up a connection Model that is sent along with the application in accordance 5.2.1 Wireless connection...