Download Print this page

Panasonic GA-311 Instruction Manual page 2

Advertisement

Mutual interference
When two or more sensors are installed in parallel or face to face, keep the
minimum separation distance specified below to avoid mutual interference.
Face to face mounting
Parallel mounting
C
D
Sensing range
The sensing range is specified for the standard sensing object. With a
non-ferrous metal, the sensing range is obtained by multiplying with the
correction coefficient specified below.
Correction coefficient
Model No.
GH-2SE
GH-3SE
Metal
Iron
1
Stainless steel
0.68 approx.
0.55 approx.
(SUS304)
Brass
0.53 approx.
0.35 approx.
Aluminum
0.51 approx.
0.33 approx.
Note: The sensing range also changes if the sensing object is plated.
4
CONNECTION
Make sure that the power supply is off while connecting / disconnecting the
quick-connection cable.
Connection method
Holding the connector of the quick-connec-
tion cable, align its projection with the
groove at the top portion of the amplifier
connector.
Insert the connector till a click is felt.
Disconnection method
Pressing the projection at the top of the
quick-connection cable connector, pull out
the connector.
Note: Take care that if the connector is pulled out without pressing the
projection, the projection may break. Do not use a quick-connection cable whose
projection has broken.
Furthermore, do not pull by holding the cable, as this can cause a cable-break.
5
CASCADING UNITS
Make sure that the power is off while cascading / removing the amplifiers.
Be sure to check the allowable ambient temperature, as it depends on
the number of amplifiers connected in cascade.
In case two, or more, amplifiers are connected in cascade, make sure
to mount them on a DIN rail.
When the amplifiers move on the DIN rail depending on the attaching
condition, fitting them between the optional end plates (MS-DIN-E)
mounted at the two ends.
When connecting in cascade, mount the amplifiers close to each other,
fitting them between the optional end plates (MS-DIN-E) mounted at the
two ends.
When connecting more than two amplifiers in cascade, use the sub ca-
ble (CN-71-C ) as the quick-connection cable for the second amplifier
onwards.
This product does not incorporate the communication function. When
this product used by cascading along with other than this product,
mount at the either side of the cascaded products.
Refer to the '
MOUNTING' for mounting / dismantling the amplifiers.
3
Cascading method
Mount the amplifiers, one by
one, on the 35mm width DIN
and set them close to each
other without any gap between
them.
Connect the quick-connection
cables to the amplifiers.
Mount the end plate (MS-DIN-E)
(optional) at both ends to hold
the units between their flat sides.
Tighten the screws to fix the
end plates (MS-DIN-E)
Dismantling
Pressing the projection at the top
of the quick connection cable
connector, pull out the connector.
Remove the amplifiers.
Ramco National
All manuals and user guides at all-guides.com
Model No.
C (mm)
D (mm)
GH-2SE
15
GH-3SE
20
GH-5SE
25
GH-8SE
40
GH-F8SE
GH-8SE
GH-5SE
GH-F8SE
1
1
1
0.69 approx.
0.64 approx.
0.41 approx.
0.37 approx.
0.39 approx.
0.32 approx.
Groove
Projection
Quick-connection cable
Projection
Sub-cable
(CN-71-C )
(optional)
Main cable
(CN-73-C ) (optional)
End plate
(MS-DIN-E)
(optional)
End plate
(MS-DIN-E) (optional)
www.PanasonicSensors.com
6
I/O DIAGRAMS
Connector pin No. for the sensor head side
10
Not used
1
15
Signal wire
2
20
Shielded wire
3
26
T
r
Not used
4
Internal circuit
Note: The quick-connection cable does not have +V (Blown) and 0V (Blue). The
supply voltage is supplied through the main cable connector.
Symbols... D
: Reverse supply polarity protection diode
Z
: Surge absorption zener diode
D
T
: NPN output transistor
r
Terminal arrangement diagram
Sensor head side connector
Not used
Signal wire
Shielded wire
Not used
7
PART DESCRIPTION
Operation indicator (Orange)
8
SENSITIVITY ADJUSTMENT
Step
Sensing condition
Set the operation mode switch to
NORM. (Initial setting)
Sensing object
A p p r o a c h
along sens-
ing axis
Sensor
head
Sensing object
A p p r o a c h
perpendicu-
lar to sens-
Sensor
ing axis
head
Select the operation mode as per your application.
(NORM.: Normally open, INV.: Normally closed)
Note: Use a flathead screwdriver (please arrange separately) to turn the adjuster
slowly. Turning with excessive strength will cause damage to the adjuster.
9
DIMENSIONS (Unit: mm)
GH- SE / Sensor head
C
B
A
GA-311 / Amplifier
Sensor head
connector
Connector cover
10
(16)
30.5
15.55
4.65
6.3
3
Note: The side view is with the sensor head connector and the quick-connection cable.
http://panasonic.net/id/pidsx/global
Overseas Sales Division (Head Office)
2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan
Phone: +81-568-33-7861 FAX: +81-568-33-8591
About our sale network, please visit our website.
PRINTED IN JAPAN
Connector pin No. for power supply side
Color code of quick-connection cable
D
(Brown) +V (Note)
1
Load
(Black) Output
+
3
100mA max.
Z
D
(Blue) 0V (Note)
2
User's circuit
Power supply side connector
V
Output
0V
Disconnection alarm indicator (Red)
Operation mode switch
Sensitivity adjuster
Adjustment
Turn the sensitivity adjuster fully coun-
terclockwise. (Minimum sensitivity)
Place the sensing object within the
stable sensing range.
Turn the sensitivity adjuster clockwise
Movement
and set it at the point
where the op-
direction
eration indicator (orange) lights up.
Place the sensing object within the
stable sensing range.
Movement
Turn the sensitivity adjuster clockwise,
direction
and set it at the optimum sensing point
which is a little beyond the point
the operation indicator (orange) lights up.
Model No.
A
GH-2SE
2.8
GH-3SE
3.8
GH-5SE
5.4
GH-8SE
8.0
Cable 3m long
GH-F8SE
8.0
1.9
0.4
21.95
33.5
2.5
53.7
64.5
36.5
14.5
© Panasonic Industrial Devices SUNX Co., Ltd. 2012
1-800-280-6933
12 to 24V DC
10%
Sensitivity adjuster
where
B
C
12
1.6
15
2.5
15
2.5
15
2.5
15
2.65
Quick-connection
connector
(7)
10.5
3.95

Advertisement

loading

This manual is also suitable for:

Gh-2seGh-3seGh-5seGh-8seGh-f8se