Axis A4 20 Series User Manual

Reader/reader with keypad

Advertisement

AXIS A4x20 Readers
AXIS A4020-E Reader
AXIS A4120-VE Reader with Keypad
User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the A4 20 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Axis A4 20 Series

  • Page 1 AXIS A4x20 Readers AXIS A4020-E Reader AXIS A4120-VE Reader with Keypad User Manual...
  • Page 2: Installation

    To watch this video, go to the web version of this document. www.axis.com/products/online-manual/70685#t10171383 Installation video for the device Wiring Connect the wires from the reader to the door controller according to the table. AXIS A4020-E AXIS A1001 Other Axis door controllers 12 V 12 V...
  • Page 3: Configure Your Device

    The device works as a standard OSDP reader out-of-the-box. You can access specific features and change settings in AXIS Camera Station Secure Entry. Below is an example of how to configure the device through AXIS Camera Station Secure Entry. Encrypted communication AXIS Camera Station Secure Entry supports OSDP (Open Supervised Device Protocol) Secure Channel to enable line encryption between controller and AXIS A4020-E Reader.
  • Page 4: Troubleshooting

    AXIS A4x20 Readers Troubleshooting Troubleshooting Reset to factory default settings A reset to factory default resets all settings to the factory default values. To watch this video, go to the web version of this document. www.axis.com/products/online-manual/70685#t10171385 1. Remove the device from the backplate. This disconnects power from the device.
  • Page 5: Specifications

    AXIS A4x20 Readers Specifications Specifications Product overview Reader indicator stripe DIP switches Control button Reader indicator stripe Behavior State Flashing red Waiting for controller connection DIP switches DIP switch Default setting Function OSDP address: Off + Off = 0* Off + On = 1...
  • Page 6 AXIS A4x20 Readers Specifications Secure mode * When switch 1 and 2 are both set to Off, you can use the command osdp_COMSET to change the address. Buttons Control button The control button is used for: • Resetting the product to factory default settings. See Reset to factory default settings on page 4 .
  • Page 7 User Manual Ver. M2.3 AXIS A4x20 Readers Date: October 2021 © Axis Communications AB, 2021 Part No. T10171378...