THERAFIN NEW PRODUCT
Flipdown Knee Adductor Assembly
Flipdown Knee Adductor Assembly
• Superior locking mechanism with very little play
• Flipdown trigger release design
• Fits
3
/
",
7
/
", and 1" tubing
4
8
• Also available to fit Quantum® seat tracks
• Available in short arm and long arm configurations
• 3 standard pad sizes, and custom is available
• 1
1
/
" thick pads are all-black textured urethane
4
self-skinning foam, with a neoprene cover
Flipdown Knee Adductor Hardware For Tubing
Short Arm, Left Side (1) . . . . . . . . . . . .30271
Short Arm, Right Side (1) . . . . . . . . . . .30272
Short Arm, Pair (1left & 1 right) . . . . .30248
Long Arm, Left Side (1) . . . . . . . . . . . .30079
Long Arm, Right Side (1) . . . . . . . . . . .30080
Long Arm, Pair (1left & 1 right) . . . . .30284
Flipdown Knee Adductor Hardware For Quantum Seat Tracks
Short Arm, Left Side (1) . . . . . . . . . . . .30255
Short Arm, Right Side (1) . . . . . . . . . . .30256
Short Arm, Pair (1left & 1 right) . . . . .30240
Long Arm, Left Side (1) . . . . . . . . . . . .30291
Long Arm, Right Side (1) . . . . . . . . . . .30292
Long Arm, Pair (1left & 1 right) . . . . .30276
Knee Adductor Pad & Neoprene Cover
3" x 4" (1) . . . . . . . . . . . . . . . . . . . . . . .50490
4" x 6" (1) . . . . . . . . . . . . . . . . . . . . . . .50491
5" x 7" (1) . . . . . . . . . . . . . . . . . . . . . . .50492
Custom Size . . . . . . . . . . . . . . . . . . . . .50493
Fits Tubing
Fits Quantum Track
THERAFIN CORPORATION
®
®
Long Arm Example
Phone 800-843-7234
Fax 888-479-1515
www.Therafin.com
order@Therafin.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the Therafin Flipdown Adductor and is the answer not in the manual?

Questions and answers

Summary of Contents for Therafin Therafin Flipdown Adductor

  • Page 1 THERAFIN NEW PRODUCT Flipdown Knee Adductor Assembly Flipdown Knee Adductor Assembly • Superior locking mechanism with very little play • Flipdown trigger release design • Fits ”, ”, and 1” tubing • Also available to fit Quantum® seat tracks • Available in short arm and long arm configurations •...
  • Page 2     Therafin Flipdown Adductor                    Owner’s Instruction Manual                  Please ensure that this booklet remains with the seating device.  This booklet  is the property of the consumer and contains important information and  instructions.                  ...
  • Page 3: Table Of Contents

    Installation ………………………………...…………………………………………  7  Adjustment………………………………………………………..…………………..  13  Operation……………………………………………………………………..………  16  Cleaning and Maintenance …………………………………………………….   17  Warranty ………………………………………………………………………………  18        GENERAL INFORMATION    Part Number this manual: 18889  Revision B      This positioning device manufactured by:  Therafin Corp.    19747 Wolf Road   Mokena, IL 60448    Hours: Monday thru Friday 7AM to 5:30PM (Central Time)   Phone toll‐free 800‐843‐7234 Fax toll‐free (24 hrs.) 888‐479‐1515  In Illinois Phone 708‐479‐7300 Fax 708‐479‐1515  Email:  info@therafin.com    Retain all instructions and manuals you that you received with your  positioning device.     Please contact your supplier/dealer with any question you have regarding  your positioning device.  Place the supplier/dealer’s name and contact  information in the space below:    Supplier: ________________________________________________________    Address: _________________________________________________________   _________________________________________________________ ...
  • Page 4: Positioning Device Information And Warnings

    WARNING       DO NOT CONTINUE TO USE THE DEVICE AFTER IDENTIFYING LOOSE  OR BROKEN COMPONENTS. FAILURE TO COMPLY MAY RESULT IN  INJURY     WARNING       DO NOT MAKE CHANGES TO THE POSTIONING DEVICE UNLESS YOU  HAVE CONSULTED YOUR AUTHORIZED SUPPLIER FIRST. FAILURE TO  COMPLY MAY RESULT IN INJURY TO THE USER.          INFORMATION:    1. Therafin provides many seating devices and accessories to meet  the needs of those who use wheelchairs and specialty devices.  The  appropriate selection of these devices and any subsequent  adjustments should be made with your health care advisor and  Therafin supplier.  The considerations for appropriate selection  include (but are not limited to):  ‐Your particular disability, your strength, your balance and  coordination.  b. ‐The environment in which you use your seating device.  ‐Your need for options and accessories for both your safety  and comfort.    2. Make sure all the attachment hardware is secure and tight.  P a g e  | 3      Therafin Corp.   2011    Part number 18889  Revision B ...
  • Page 5 6. For Attendants:   Consult the user’s doctor, nurse or therapist before  assisting the user.  b. To prevent injury to your back, use good posture and  proper body mechanics when you lift or support the user.   This includes bending your knees slightly and keeping  your back upright and straight.  7. Inspect and maintain this device regularly. If you detect a problem,  make sure to service or repair the device before use.  8. Some of the screws bolts and nuts on this device are special high‐ strength fasteners.  9. ONLY use fasteners provided by your supplier.  10. Over‐ or under‐tightened fasteners may fail or cause damage to  chair parts.  11. If bolts or screws become loose, tighten them as soon as you can.  12. Therafin recommends that all fasteners be checked for wear, such  as loose bolts or broken components every 3 months or as needed.   13. Loose fasteners should be retightened according to the installation  instructions.   14. Check the function of all moveable parts during each use. Insure  they adjust and lock into position to provide the necessary support  to the user.  15. When hinged or adjustable components are moved there may be a  “pinch point”. Be aware of these points and insure all body parts  are kept clear during movements and adjustments.           ...
  • Page 6: Identification Of Parts

    IDENTIFICATION OF PARTS    Shown below is the Tubing Mounted Configuration of the Adductor.  This  device will clamp securely to tubing with a diameter of:  3/4”,  7/8”  or 1”       Shown below is the Quantum Rail Mounted Configuration of the  Adductor.  This device will clamp securely to the side rails of a Quantum  power mobility base.    All Parts are the same as above except for the Tube Clamp    and Tube Clamp Bolts – these are replaced by the Quantum Rail Mount.                         P a g e  | 5      Therafin Corp.   2011    Part number 18889  Revision B ...
  • Page 7                  LONG ARM                 SHORT ARM                                                        P a g e  | 6      Therafin Corp.   2011    Part number 18889  Revision B ...
  • Page 8: Installation

    A. Loosen the Collar Bolts on the Adductor Assembly and remove the  Tube Clamp by sliding outward.                                    B. Determine a location along the wheelchair frame or legrest to  attach the Tube Clamp.                            P a g e  | 7      Therafin Corp.   2011    Part number 18889  Revision B ...
  • Page 9                     D. Re‐insert the Adductor Assembly onto the Tube Clamp.                                                P a g e  | 8      Therafin Corp.   2011    Part number 18889  Revision B ...
  • Page 10   Slide Collar snugly against the Washer and Flip Down Clamp and  ensure that the Axle does not protrude.  Tighten Collar Bolts.          Collar snug against    Washer and Flip Down      Clamp                          Axle not      protruding      past Collar        P a g e  | 9      Therafin Corp.   2011    Part number 18889  Revision B ...
  • Page 11                     B. Determine a location along the track located on the wheelchair  frame to attach the Quantum Mount. Slide the Quantum Rail Mount  into the track to the desired location.                                            P a g e  | 10      Therafin Corp.   2011    Part number 18889  Revision B ...
  • Page 12                     D. Re‐insert the Adductor Assembly onto the Quantum Rail Mount.                                                P a g e  | 11      Therafin Corp.   2011    Part number 18889  Revision B ...
  • Page 13                   Slide Collar snugly against the Washer and Flip Down Clamp and  ensure that the Axle does not protrude.  Tighten Collar Bolts.        Collar snug against    Washer and Flip Down      Clamp                    Axle not    protruding      past Collar  P a g e  | 12      Therafin Corp.   2011    Part number 18889  Revision B ...
  • Page 14: Adjustment

    ADJUSTMENT       The Therafin Adductor Positioning Device has several adjustments to  provide the correct user support.      Adjustments can be made for:    1. Distal/Proximal Location  2. Height Adjustment  3. Medial/Lateral Adjustment  4. Pad Angle    To make Distal/Proximal adjustment:    1. Loosen the Tube Clamp Bolts (or Quantum Rail Mount Bolts) and  slide the hardware along the wheelchair frame to the desired  location.  2. Re‐tighten fasteners securely when the desired location is  achieved.                           ...
  • Page 15                     To make Height adjustment:    1. Loosen the Flip Down Clamp Bolts and slide Rod in the Assembly to  the desired height.  2. Re‐tighten fasteners securely when the desired location is achieved.                                      P a g e  | 14      Therafin Corp.   2011    Part number 18889  Revision B ...
  • Page 16: Operation

                              To make Pad Angle adjustment:    1. Loosen the Pad Clamp Bolts and rotate the Pad to the desired angle.  2. Re‐tighten fasteners securely when the desired location is  achieved.                              OPERATION  P a g e  | 15      Therafin Corp.   2011    Part number 18889  Revision B ...
  • Page 17: Cleaning And Maintenance

    1. Depress the Trigger to release and rotate the Assembly forward or  backward.  2. Raise the Assembly into the original position until it locks in place  securely.                                                            CLEANING & MAINTENANCE  P a g e  | 16      Therafin Corp.   2011    Part number 18889  Revision B ...
  • Page 18       CLEANING:    UPHOLSTERY AND/OR FABRICS:  Surfaces may be wiped clean with mild soap and water. Do not use harsh  detergents, cleaning agents or abrasives.  Avoid the use of polishes that can  make the surfaces slippery after cleaning.    POSITIONING COMPONENTS AND HARDWARE:  Wipe clean with mild soap and water. Do not use harsh detergents,  cleaning agents or abrasives.  Avoid the use of polishes that can make the  surfaces slippery after cleaning.  Do not submerse components underwater.    If you have any additional questions about how to clean or maintain your  device please contact your Therafin dealer or agent.    MAINTENANCE:    WARNING       FAILURE TO FOLLOW THE MAINTENANCE BELOW MAY RESULT IN  INJURY TO THE USER.     WARNING       DO NOT CONTINUE TO USE THE DEVICE AFTER IDENTIFYING LOOSE  OR BROKEN COMPONENTS OR FASTENERS:    Therafin recommends that all fasteners should be checked for wear every 3  months.  Perform an inspection for loose bolts or broken components every 3  months.     Loose fasteners should be retightened according to the  installation instructions. All fasteners should be tightened to torque ...
  • Page 19: Warranty

          DO NOT CONTINUE TO USE THE DEVICE AFTER IDENTIFYING LOOSE  OR BROKEN COMPONENTS. REMOVABLE, ADJUSTABLE OR HINGED  COMPONENTS.    Check the function of all moveable components during each use. Insure they  adjust and lock into position and supply the  necessary support to the user.          WARRANTY      Limited Warranty  Any product found to be defective due to the material  or workmanship within one year will be replaced  under our return policy following product evaluation  by Therafin Corporation. This replacement warranty  does not include misuse or neglect of the product.      Liability  While Therafin Corporation is responsible for any  product that is defective due to manufacturing by  Therafin Corporation, we are not liable for misuse or  misapplication of our products. To achieve optimum  performance, it is recommended that experienced  professionals be consulted in the selection and application   of our products.        P a g e  | 18      Therafin Corp.   2011    Part number 18889  Revision B ...
  • Page 20 Flipdown Knee Adductor Hardware Item Description Retail HCPC 30271 Flip Down Knee Adductor W/Short Arm & Tubing Adaptor, Left 285.00 E1028 30272 Flip Down Knee Adductor W/Short Arm & Tubing Adaptor, Right 285.00 E1028 30248 Flip Down Knee Adductor W/Short Arm & Tubing Adaptor, Pair 285.00 E1028 30079 Flip Down Knee Adductor W/Long Arm &...