Installer Setup-Operation Setup - Panasonic Secon H Series Installation And Setup

Monobloc system
Table of Contents

Advertisement

After setting up System Setup scroll back to the Installer Setup menu and choose Operation
Setup which will give you the options to set up HEAT and TANK modes. Set each up as below
For test purposes set this at 55C—45C—minus 5C and 15C respectively
When testing is finished we recommend changing this to
For underfloor heating 35C—30C —minus 5C and 15C respectively
For modern radiators 45C—35C —minus 5C and 15C respectively
For old fashioned radiators 52C—40C —minus 5C and 15C respectively
T: 0191 516 6554
Installer Setup—Operation Setup
W: www.seconrenewables.com
Set this as
Compensation
Curve with set-
tings as below
in red
Set this as 35C
during testing
then drop to
20C after test
Set this at 5C
Set this at
Minus 5C
Set this at
1 hour
Set this at
40 minutes
E: