Automatic A/C-Service Unit
3.
Control panel
The upper panel of the unit contains all control elements needed for operation, checking for tightness
and measuring the A/C system operating pressures.
3.1
D
ESCRIPTION OF THE CONTROL KEYS
Ref. 11: when pressed, they enhance the function to perform or to modify. From the left, you will find the
o
following functions: RECOVERY/RECYCLING, VACUUM, OIL CHARGE, UV CHARGE,
REFRIGERANT CHARGE, FLUSHUNG, FIRE&GO, AUTO
The numeric keys ref. 16 allow to modify the values of the functions to perform
o
The UP / DOWN key ref. 89 allows to modify the values of the functions to perform
o
The ENTER key ref. 98 must be used to confirm the modified values
o
The MENU key ref. 22 is used to see the pages of the unit's inside values on the display (ref. 28):
o
•
PRINT PLATE: by typing the car's number plate on the numeric keys (ref. 16), the
number plate will be printed on the report at the end of the functions
•
LANGUAGE: it is possible to modify the unit's language, by typing the corresponding
number appearing on the display
•
DATABASE UPDATE: allows to update data
•
DATE AND HOUR: allows to modify the date and hour mentioned on the printed report
•
SCALES CALIBRATION: must be used each time the operator wants to re-calibrate one
of the four scales
•
SERVICE: constants that are inside the unit and are protected by PASSWORD
Letzte Änderung: 24.06.2009 / Art.Nr.: 2059ENG
fig.1
1. PASSWORD 2006 allows to modify the print heading of the report
2. PASSWORD 5011 allows to reset the counters concerning maintenance
3. PASSWORD 9376 allows to reset simultaneously the 4 scales
15