It is possible to modify the refrigerant charge by means of the keyboard or using the DATABASE of the
unit.
2.13 F
UNCTIONS THAT CAN BE PERFORMED
a) Coolius 4000 BUS unit allows to perform the functions singly one after the other, being able to
modify the relevant values
b) Coolius 4000 BUS unit allows to have a completely automatic programme, called AUTO, controlled
by the operator, with the following functions
Refrigerant RECOVERY
RECOVERY TEST
DISCHARGE of OIL recovered from the system
VACUUM and VACUUM TEST
OIL CHARGE
UV CHARGE
REFRIGERANT CHARGE
c) If the operator does not want to perform a function, he must set a value of 0.0 during programming.
d) Coolius 4000 BUS unit allows to have a programme called FIRE & GO, with which the unit will
perform automatically the same functions as the ones in the AUTO programme; the only exception
is that only the refrigerant charge value can be modified.
e) Coolius 4000 BUS unit allows to perform the A/C system flushing with R134a. By pressing the
START key, the unit will perform the following functions automatically:
VACUUM and VACCUM TEST (this function is performed only at the first cycle)
SYSTEM FLOODING
REFRIGERANT RECOVERY
OIL DISCHARGE ( this function is performed at the first and last cycle)
f)
Should there be an alarm signal during any automatic or single function, the function will stop and
the alarm message will be stored on the display.