Static Clean Particle Trap Cube Operation Manual

Advertisement

Quick Links

Particle Trap
Thank you for purchasing the Particle Trap Cube (PT Cube). Although this device is not specified as a high
voltage device according to electrical equipment standards, it uses high AC voltages and we therefore ask
that it be operated correctly after carefully reading this instruction manual. Please store this manual
carefully and utilize it appropriately when required.
Safety Precautions
Because this device uses high internal voltages, there is the possibility that incorrect usage can lead to
physical injury or damage to the product. This company does not accept any responsibility for uses outside
the parameters of the product specifications or failure to follow these safety precautions.
This device does not conform to explsion-proof specifications. Do not install or use it in
locaions or atmospheric conditions where flammable gases or solvent are handled. Doing
so many result in fire or explosion.
Because high voltages are applied to the emitter pin, keep it away from conductive objects
such as your fingers and body, wires, tools, etc. It may cause electrical shock or damage.
Because the tip of the emitter pin is sharp, take sufficient care when handling it. It may
cause injuries.
Warning
Do not under any circumstances disassemble, repair, or modify this device. Doing so may
cause an accident or damage.
Connecting, installing, and maintenance must be with the power turned off. Failure to do
so may cause accidents or damage.
Because the fan rotates at high speed when the power is on, do not insert small objects
etc. between the gaps in the guard. Doing so may cause an accident or damage.
Because this device incorporates devices that generate high voltages, avoid installing it in
wet, oily, hot, and humid locations. In particular, avoid using it in locations of high
humidity and condensation.
Be sure to ground the device. Failure to do so can cause deterioration of its neutralizing
characteristics, malfunction, and damage.
If the product does not work anymore or is no longer required, dispose of it in the
appropriate manner as industrial waste.
Note
Carry out wiring and ducting correctly. If done incorrectly, it can lead to diminished
performance and damage.
Because this device generates high voltages, management of operation, maintenance,
etc. should be carried out by a sufficiently knowledgeable and experienced person.
R
Cube Operation Manual
®
V0.969-S16
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Particle Trap Cube and is the answer not in the manual?

Questions and answers

Summary of Contents for Static Clean Particle Trap Cube

  • Page 1 ® Particle Trap Thank you for purchasing the Particle Trap Cube (PT Cube). Although this device is not specified as a high voltage device according to electrical equipment standards, it uses high AC voltages and we therefore ask that it be operated correctly after carefully reading this instruction manual. Please store this manual carefully and utilize it appropriately when required.
  • Page 2 Check whether any of the following items are missing, whether there are any irregularities, and whether they have been damaged during transit before use. If there is any damage or Static Clean International the product does not operate correctly, please contact ①...
  • Page 3 5. Exterior, Names and Functions of Components Diagram of Setting/Display Panel External Diagram of Main Unit 5-1 Explanation of Main Unit Components Description Component Work inlet Insert the work to eliminate static charges and clean. Detach this when cleaning the inside of the main unit. When detaching, remove the knurled Main unit perforated floor screws (one on each side) in the sides of the main unit for holding this floor in place.
  • Page 4 5-2 Setting/Display Panel Component Description Power switch The main switch of this device. Pulse Sets the pulse of the air blow. You can select 1Hz, 3Hz, 5Hz, 10Hz, or continuous air blow (‘Cont’). Blow mode Sets the air blow time. Set ‘Real’ mode to turn the blow on and off by means of a sensor; OR set to setting Time 3 sec, 5 sec, 10 sec, or 15 sec continuous air blow from when sensor first detects (sees) a part...
  • Page 5 Connect a compressed air line to the filter/regulator assembly at the back of the unit. • Install (1) 3/8” NPT Male x Female Elbow (shipped loose with PT Cube) into the 3/8” NPT Female port of the filter regulator, oriented up, down or rear-facing as desired after tightening with a wrench.
  • Page 6 7-2 Procedure When Finishing Operation ① Turn the power switch of the device off. ② Close your air valve from your ‘house’ compressed air system (not included with this system) to prevent a leak or wasted energy. 7-3 Alarm Cancellation Procedure The device has a function for displaying on the main unit display panel when fan rotation stops or there is an irregularity in the ionizer.
  • Page 7 8-2 Ionizer Cleaning Procedure • Although a cover is attached so that the emitter pin cannot be touched, the tip portion of the emitter pin is very sharp. Use caution when handling or it may result in injury. ① Check that the power switch is turned off and the Air pressure gauge reading is 0 psi. ②...
  • Page 8 • Replacement 10-micron exhaust filters (x5): p/n PTCFLT • Replacement 5-micron filter/regulator element: p/n AF40-060S • Replacement 0.3-micron secondary filter element: p/n AFM40P-060AS Please contact us if you have any questions or concerns, at: STATIC CLEAN INTERNATIONAL www.staticclean.com ※ (877) 782-8423 ※ techsales@staticclean.com Ver.2 20200924...