EN: Installation Sheet
WARNING!
Electrocution hazard. To avoid personal injury or
death from electrocution, remove all sources of power and
allow stored energy to discharge before installing or removing
equipment.
You must be free of static electricity before handling circuit
boards. Wear a grounding strap or touch a bare metal surface
to discharge static electricity.
© 2020 UTC Fire & Security Americas Corporation, Inc.
(2)
(3)
+
(4)
(5)
D8
D7
D6
D5
D4
D3
D2
D1
(7)
(8)
(11)
Description
The purpose of the repeater is to receive and retransmit
signals from wireless sensors, wireless keyfobs (only for 63bit
protocol), and other repeaters.
Depending on protocol settings, the repeater supports either
433 MHz 63bit sensors, or 433 MHz LoNa sensors, but not
both. See "DIP switch settings" on page 2 for details.
Figures: Device layout
(1) 230 VAC power connector
(2) Battery
(3) Radio antenna for
transceiver 2
(4) Status LEDs
(5) DIP switch
(6) Power supply unit
Symbol definitions
Item
Description
~
Alternating current
Class II equipment
Danger of electric shock
Installation guidelines
Installation only by a trained installer.
1.
Mount and fasten the repeater to the wall with M4 flat
head screws.
2.
Fasten the tamper screw.
Connect power according to "Power options" on page 2.
3.
4.
Latch the housing cover so it locks securely into place.
5.
Secure the housing with the protective screw at the side of
the housing cover.
Follow below guidelines when installing the repeater:
Before mounting the device, use D1 to D8 LEDs and
check signal strength and noise floor.
Strongly recommended at least 50 cm of clearance above
the enclosure.
Avoid areas with excessive metal or electrical wiring,
including furnace and utility rooms.
Avoid mounting in a location that exposes the module to
high humidity.
1 / 7
(7) Diagnostic button
(8) Tamper switch
(9) Diagnostic connector
(10) Transceiver 1
(11) Transceiver 2
(12) Radio antenna for
transceiver 1
P/N R466-5569-EN • REV B • DRAFT A03

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RF-9011-07-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Interlogix RF-9011-07-1

  • Page 1 RF-9011-07-1 Smart Repeater 433 MHz Installation Sheet PCB front view Description The purpose of the repeater is to receive and retransmit signals from wireless sensors, wireless keyfobs (only for 63bit protocol), and other repeaters. Depending on protocol settings, the repeater supports either 433 MHz 63bit sensors, or 433 MHz LoNa sensors, but not both.
  • Page 2 • Do not use the repeater in combination with other repeater WARNING: Lithium-ion battery! models. Risk of burned skin, blindness, or death. • Mount the repeater only inside the supervised premises. Risk of explosion or disabled safeguard if the battery is replaced by an incorrect type or subjected to Repeater features extremely low air pressure.
  • Page 3 • Star – a network of repeaters with sensors To enable the walk test mode, set DIP switch 1 to On. The walk test mode is indicated on LEDs by intermittent switching Panel Sensor of four upper and four lower LEDs. ID 8 Once the walk test mode is enabled on the repeater, perform Sensor...
  • Page 4 • Repeater X should be learned into the repeater Y only if Repeater configuration limits repeater Y is retransmitting signals from repeater X, and Maximum number of repeaters in a repeater’s database: 4. connection between them is direct. Maximum number of sensors in a repeater’s database: 64. For example, in the mixed network in figure above: Note: The maximum number of sensors should not exceed the...
  • Page 5: Led Patterns

    See the figure below for additional information. Noise Floor Level Push the Diagnostic button once more to show the noise floor level from the last transmission on LEDs D2 to D8 (from LED D8 downwards). LED D1 will flash twice every second. D8 low noise level D7 good level away from...
  • Page 6: Specifications

    For more information see: 3211 Progress Drive, Lincolnton, NC, 28092, USA recyclethis.info Authorized EU manufacturing representative: UTC Fire & Security B.V. Contact information Kelvinstraat 7, 6003 DH Weert, Netherlands firesecurityproducts.com or www.interlogix.com P/N R466-5569-EN • REV B • DRAFT A03 6 / 7...
  • Page 7 Sensors learned in the repeater Number Sensor ID Sensor type Number Sensor ID Sensor type Repeaters learned in the repeater Number Repeater ID P/N R466-5569-EN • REV B • DRAFT A03 7 / 7...

Table of Contents