Page 1
® AUDION ELEKTRO Audionvac Digital VMS 43-53-93-113-133-133L MANUAL VMS 43 t-m 133L ENG Rev14...
Page 2
(mis)interpretation of the contents. AUDION ELEKTRO is not responsible for damage or problems which result from the use of other than the original spare parts. If this manual has not been supplied with instructions for certain repairs, adjustments and maintenance, you should contact your dealer of...
Contents Precautions ..........................5 Explanation of the clip arts ....................5 Prohibitions ......................... 6 Installation ............................ 7 Description of the workplace ................... 7 Checking the oil level ......................7 Taking into use ........................8 Programming ..........................9 Description of the program cycle for digital time control ........... 10 Set / change function values ..................
Page 4
INTRODUCTION With the purchase of this vacuum chamber machine you will be able to pack a great variety of products. To use the vacuum chamber machines Audion made sure that all the machines, from the smallest to the biggest model, fulfill the greatest demands. Besides the superior quality of the machines they are all very easy to handle.
Identification plate with Voltage(V), Frequency(Hz) and Consumption(W) O.K. Fluid Long period Do not continue, this is dangerous Contact Audion Elektro BV or your dealer Watch out! Reparation/ Maintenance Audion Elektro BV Symbol for your Audionvac machine Temperature meter with boundary conditions...
Prohibitions Never pack live material. Don’t pack in a clean room environment. Don’t use in an explosive environment. Don’t pack in a medical, sterile environment. Don’t pack pharmaceutical and / or therapeutically products. Don’t use gas-mixtures containing higher concentrations than 25% of oxygen (O2) because danger of explosions.
Installation Description of the workplace Whenever the model is a table model place it on a firm and stable table. Place the model on the ground in a well ventilated and luminated space when you’re dealing with a floor model. Make sure the Audionvac isn’t exposed to sunshine, extreme temperatures, humidity, dust or sand.
The oil will become warm then. Figure 2.2a: oil filling plug Figure 2.2b: oil level glass Figure 2.2c: oil draining plug (lower plug only at VMS 43/53) and draining plug (only VMS 43/53) (VMS 113/133) Taking into use 0-30°C...
STOP keys for complete function interruption or for only active function interruption. There are also a number of built-in service programs. Contact the supplier or Audion Elektro B.V. for more information about these functions. The value of the functions can be set for a certain time period.
FUNCTION DURING CYCLE (5): INTERRUPTION OF THE VACUUM FUNCTION DURING THE PROGRAM CYCLE. THE CYCLE IMMEDIATELY CONTINUES WITH THE NEXT FUNCTION. GENERAL FUNCTION: INCREMENT THE VALUE OF THE SELECTED FUNCTION. Function during cycle (6): Terminates the program cycle completely. The cycle immediately switches into the ventilation function.
The conditioning program for the pump is the most used service program (see explanation on page 17). Contact the supplier or Audion Elektro B.V. for more information about the use of other service programs. After switching to the user mode the display could read “oil”. This means that the operating hours counter is turned on and the set number of operating hours has elapsed.
For all the other reparations please contact your dealer or Audion Elektro BV. The schedule mentioned in § 4.1 is for normal use of the machine. When the machine is being used intensively or under extreme circumstances it is necessary to do more frequent maintenance.
Regular maintenance Daily maintenance Vacuum chamber and insert Clean the lid, insert plates and chamber with a damp cloth. plates Treat the rubber strip in the lid with talk powder. Warning! The transparent lid should never be treated with synthetic cleaner as it weakens the material Vacuum pump Run the conditioning program “§...
Maintenance of the seal bar The maintenance of the seal bar consists of: Cleaning the PTFE and controlling the PTFE for burned places. − Check the seal wire and replace when necessary − 4.2.1 Removing the seal bar Switch off the machine. −...
Maintenance of the vacuum pump In case of irregular or intensive operating you will have to “condition” the machine. When a vacuum pump doesn’t reach the ideal temperature there is a chance the vacuumed air contains water which leads to condensation inside the pump. Water in the pump can lead to corrosion, which can be very harmful for then pump.
Problem solving For questions please disconnect the power and contact your dealer or Audion Elektro BV. Problem Possible cause Solution The machine does not work. The plug is not inserted in the Insert the plug in the socket. wall socket.
In case we replace spare parts to fulfill our guarantee engagement, the spare parts replaced become property of AUDION ELEKTRO. In case the opposite party does not come up completely, partially or does not come up in time to the obligations arisen from the engagement closed between the parties, we are not obliged to guarantee as long as the situation continues.
PART 2: TECHNICAL MANUAL Recommended spare parts Spare parts list for VMS 43 Quantity per Description Size / Specification Part numbers machine PTFE tape 0.33 m 160-1416621 Seal wire (DS 3.5mm width) 0.43 m 160-1416111 Seal wire (CS 1.1mm width) 0.43 m...
Page 19
Spare parts list for VMS 53 Description Size / Specification Part numbers Quantity per machine PTFE tape 0.33 m 160-1416621 Seal wire (DS 3.5mm width) 0.43 m 160-1416111 Seal wire (CS 1.1mm width) 0.43 m 160-1416121 Seal wire (8mm width) 0.43 m 160-1416136 Silicone rubber...
Page 20
Spare parts list for VMS 93 Description Size / Specification Part numbers Quantity per machine PTFE tape 0.40 m 160-1416621 Seal wire (DS 3.5mm width) 0.50 m 160-1416111 Seal wire (CS 1.1mm width) 0.50 m 160-1416121 Seal wire (8mm width) 0.50 m 160-1416136 Silicone rubber...
Page 21
Spare parts list for VMS 113 Description Size / Specification Part numbers Quantity per machine PTFE tape 0.40 m 160-1416621 Seal wire (DS 3.5mm width) 0.50 m 160-1416111 Seal wire (CS 1.1mm width) 0.50 m 160-1416121 Seal wire (8mm width) 0.50 m 160-1416136 Silicone rubber...
Page 22
Spare parts list for VMS 133 Description Size / Specification Part numbers Quantity per machine PTFE tape 0.47 m 160-1416621 Seal wire (DS 3.5mm width) 0.57 m 160-1416111 Seal wire (CS 1.1mm width) 0.57 m 160-1416121 Seal wire (8mm width) 0.57 m 160-1416136 Silicone rubber...
Page 23
Spare parts list for VMS 133 L Description Size / Specification Part numbers Quantity per machine PTFE tape 0.47 m 160-1416621 Seal wire (DS 3.5mm width) 0.57 m 160-1416111 Seal wire (CS 1.1mm width) 0.57 m 160-1416121 Seal wire (8mm width) 0.57 m 160-1416136 Silicone rubber...
Technical specifications TYPE VMS 43 VMS 53 VMS 93 VMS 113 VMS 133 VMS 133 L Machine size (L x W x H) in mm. 330x450x295 330x450x295 450x525x370 450x525x385 490x525x430 490x610x445 410x460 Effective chamber size in mm. 270x310 270x310 340x370...
The electric diagrams shown in this manual are basic/concept drawings. The details of the electric components are described in the index sheets. Find the correct index sheet and the electric drawings by: machine model (VMS 43, 53, voltage (110V, 230V, Model & voltage VMS 53 –...
Need help?
Do you have a question about the VMS 43 and is the answer not in the manual?
Questions and answers