Mitsubishi Heavy Industries SRK28HJ Technical Manual page 5

Wall mounted type room air conditioner
Table of Contents

Advertisement

Model SRK40HJ (Indoor unit)
SRC40HJ (Outdoor unit)
Item
Cooling capacity
(1)
(1)
Heating capacity
Power source
Cooling input
Running current (Cooling)
Heating input
Running current (Heating)
Inrush current
COP
Sound level
Cooling
Power level
Noise level
Sound level
Heating
Power level
Exterior dimensions
Height x Width x Depth
Color
Net weight
Refrigerant equipment
Compressor type & Q'ty
Motor
Starting method
Heat exchanger
Refrigerant control
Refrigerant
(3)
Refrigerant oil
Defrost control
Air handling equipment
Fan type & Q'ty
Motor
Air flow (at High)
(Cooling)
(Heating)
Air filter, Q'ty
Shock & vibration absorber
Electric heater
Operation control
Operation switch
Room temperature control
Pilot lamp
Safety equipment
O.D
Connecting method
Attached length of piping
Insulation
Drain hose
Power source cord
Connection
Size x Core number
wiring
Connecting method
Accessories (included)
Optional parts
Notes (1) The data are measured at the following conditions.
Item
Operation
Cooling
Heating
(2) The operation data are applied to the 220V or 230V districts respectively
(3) The refrigerant quantity to be charged includes the refrigerant in 5m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, it is 5 to 15m, add 30g refrigerant per meter.
Model
SRK40HJ
W
W
kW
A
kW
A
A
42
56
dB
42
56
mm
275 x 790 x 190
Ivory white
kg
9.5
kW
kg
R22 1.08 (Pre-Charged up to the piping length of 5m)
R
Tangential fan x 1
W
18
8.5
CMM
9.0
Polypropylene net (washable) x 2
Wireless–Remote controller
MC. Thermostat
RUN(Green), TIMER(Yellow), HI POWER(Orange), ECONOMY(Green)
mm(in)
Liquid line: ø6.35 (1/4") Gas line: ø12.7 (1/2")
Liquid line: 0.4m
Gas line
1.5mm
Indoor air temperature
DB
WB
27°C
19°C
20°C
3
-
-
: http://splitoff.ru/tehn-doc.html
3600
4200
1 Phase, 220/230V, 50Hz
1.39
6.6
1.35
6.4
35.0
cooling : 2.59
Heating : 3.11
RH231VXAC (Rotary type) x 1
Louver fins & bare tubing
Capillary tubes
0.52 (DIAMOND MS-56)
MC control
Cushion rubber (for compressor)
Dome mounted protector (for compressor)
Internal thermostat (for fan motor)
Flare connecting
: 0.35m
Necessary (Both sides)
Connectable
2.5m (3 cores with Earth)
2
x 5 cores (Including earth cable)
Terminal block (Screw fixing type)
Mounting kit
Outdoor air temperature
DB
WB
35°C
24°C
7°C
6°C
SRC40HJ
50
64
50
64
542 x 790 x 250
Polar white
37
1.1
Line starting
Propeller fan x 1
20
28
28
Standards
ISO-T1, JIS C9612
ISO-T1, JIS C9612