Electrical Data; Electrical Wiring - Mitsubishi Heavy Industries SRK28HJ Technical Manual

Wall mounted type room air conditioner
Table of Contents

Advertisement

3 ELECTRICAL DATA

3.1 Electrical wiring

Model SRK28HJ
Power source
1 Phase 220/230V 50Hz
FM
I
Printed circuit board
FM
Color symbol
BK
Black
BL
Blue
BR
Brown
RD
Red
OR
Orange
WH
White
Y/GN
Yellow/Green
Meaning of marks
Symbol
Cc
Capacitor for CM
CF
Capacitor for FM
I
CF
Capacitor for FM
O
CM
Compressor motor
F
Fuse
FM
Fan motor (Indoor unit)
I
FM
Fan motor (Outdoor unit)
O
FM
Flap motor
Table of relay operations
Operation
Cooling
Relay
Control
symbol
part
×
52X
20S
4
52X
FM
5
O
52C
CM
Notes (1)
: denotes magentized relay
(2) Th1 is room temperature thermistor. Th
14, 15, 17 )
Indoor unit
ireless
R-Amp
Display
52X
52C
52X
4
5
Parts name
I
O
Heating
Defrost
×
×
×
: denotes demagnetized relay
(the heat exchanger thermistor) is the hot start, hot keep, and frost prevention thermistor. (for details, refer to pages
2
-
Outdoor unit
20S
Symbol
Th
Thermistor
1, 2
Tr
Transformer
ZNR
Varistor
20S
4 way valve, coil
51C
Motor protector for CM
52C
Magnetic contactor for CM
52X
Auxiliary relay
4, 5
8
-
: http://splitoff.ru/tehn-doc.html
CM
FMo
Parts name

Advertisement

Table of Contents
loading

This manual is also suitable for:

Srk40hj

Table of Contents