manual wire
8
feeding button
switching button
9
gas check button
10
lock button
11
mode select
12
button
welding control
13
welding method
14
material
15
wire diameter
16
fuse (8A)
17
wire feeding motor
power source
18
switch
※1 【 Deepen 】 function is an optional software package. The test welding can last for 3 hours after setting P
menu (
Section 5.4). If you desire to continue this function, please contact the Distributor to activate the
function.
Note:
1. The welding material, welding wire diameter being set in (○
conditions.
2.If there is no welding data in welding material, welding wire diameter , it shows "--- ---", as shown in the picture
below.
Names and functions
● The function is used to feed welding wire into the liner before welding by holding
this key.
・ manual wire feeding speed is decided by the welding current.
● To switch the setting among" initial ", " Weld ", " crater " current.
・ For crater OFF, it can not be switched. Only the setting for " Weld " current can be
selected.
● It is to check shield gas and adjust flow rate.
・Normally, the indicator lamp is off. The lamp is on while checking gas.
・To perform the gas check, press this button and then release, then the gas valve of
the wire feeder is turned ON and then turned OFF in 20 seconds.
Press this button once again to terminate the gas check immediately.
● During stand-by, long press button for 1 second to lock the panel. Then all buttons
on the panel expect ○
potentiometer can be adjusted.
● Weld: welding condition setting for ○
check, gas check for welding, ○
・ F. Adj: fine adjustment on F. Adj menu (
・ Call: To call the welding condition being recorded (
・ Record: To record the present welding conditions (
● For welding control method selection, (
・ crater OFF: regular welding.
・ crater ON: regular welding ~ crater welding.
・ initial ON: initial welding ~regular welding ~ crater welding.
・ spot welding: The welding lasts certain seconds according to the spot welding time
being set. The welding stops automatically when the spot welding time is up.
● To select the welding method
・ Standard: No pulse during welding.
・ OP1: Reserve.
・ root welding: NO pulse root welding ※1.
・ Deepen: NO pulse deep penetration ※1.
● select the material to be welded
・ OP1 and OP2 are reserved for special design.
● select welding wire diameter to be used
・ OP1 reserved for special design.
● protection on the wire feeding motor
Note: be sure to turn off the power source switch before replacing the fuse.
● switch the power source ON and OFF
2
- - -
can NOT be operated but the wire feeder
3
6
8
9
10
, ○
2
~○
7
for panel lock
11
Section 5.4).
Chapter 8 )
)~(○
)should be in line with the actual operational
16
15
5
- - -
17
and ○
, ○
for wire feeding
9
8
16
13
10
Section 5.4).
Section 5.4).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Yd-500fd2

Table of Contents