  • Page 1: Table Of Contents

    Galanz Service Manual Condensing Dryer model:DC-80S1E,DC-80S1U contents pages 1. Technical data 2. Parts list 3. Picture of complete machine 4. Explosive view 5. wiring scheme 6. circuit diagram 7. key function 8. indicator light function 9. program function 10. fa ult dete cted f unction 11.
  • Page 2: Technical Data

    Overall size 595*630*845mm Drum Capability Weight 45KG Power Connection Voltage:230V Frequency:50Hz Maximum Power DC-80S1E(2500W) DC-80S1U(2700W) 1.2 Electrical Component 1.21 Heating Tube 1.22 Rated Voltage:230V 1.23 rated power:800W/1400W ,deviation range: +5% -10% 1.24 temperature controller: TOD 36FXE L170C temperature sensor:B25/75=3965K ±1% 1.25...
  • Page 3: Parts List

     2. Parts list Model: Model Mane Quantity Material quality DC80S1E.5.1 Door AS Binder DC80S1E.6 Down Panel AS Binder DC80S1E.5.2 Front Cover AS Binder DC80S1E.3 Control Panel AS Binder DC80S1E.1.2 Door supporter AS Binder DC80S1E.1.3 Side Board AS Binder DC80S1E.4 Water Bracket AS Binder DC80S1E.1.1...
  • Page 4 DC80S1E.4-4 Water Pipe Linker DC80S1E.4-5 Water Bracket PP116 DC80S1E.1.1-11 Overflow water Pipe PP+ rubber DC80S1E.6-4 Grid Axes 2Cr13 DC80S1E.6-1 Down Panel DC80S1E.6-2 Grid DC80S1E.6-3 Lock Button Binder DV60Q1E.7.1-1 Lifter PP116 DC80S1E.7.1 Drum Rivet joint module Binder DC80S1E.5.2-2 Door Lock Decorative PP116 Cover DC80S1E.5.2-3...
  • Page 5 DC80S1E.1.1-1 Base Bracket PP116 XDQ11-05 Capacitor Binder XDQ20-01 Pump Binder DC80S1E.1.1-8 Float DC80S1E.1.1-15 Baffle PP116 DC80S1E.1.1-7 Pump Fixture Cover PP116 DC80S1E.1.1.1-4 Idler Spring 65Mn DC80S1E.1.1.1-5 Circulate Fan HS-PA66NM-30G XLD01-08 Fan Washer galvanized DC80S1E.1.1.1-3 Motor Cushion DC80S1E.1.1.1-2 Motor Cover XDQ04-15 Motor Binder DC80S1E.1.1.1-8 Idler Washer...
  • Page 6: Picture Of Complete Machine

     3. Picture of Complete Machine...
  • Page 7: Explosive View

     4 Explosive view...
  • Page 10  5. Electric Diagram...
  • Page 11: Circuit Diagram

     6. Circuit Diagram...
  • Page 12: Key Function

     7. Key Function “ ” Start/Pause button Press this button to start or pause the machine. After choosing the Buzzer function, it will make out a “B” sound every time you press the button. “Delay Start” button By pressing this button, you can select delay programme from 1~ 24 hours. This option must be selected after having selected the programme.
  • Page 13: Indicator Light Function

    “ ” Child Lock combination key 同时按下“Delay Start”和“Delicate” Press meantime “Delay Start” and “Delicate” button for several seconds to turn on or off the Child Lock Fuction.  8. Indicator Light Function “Buzzer”light 。This light indicates the Buzzer function is on. Pressing buttons after selecting required programmes or rotating the dial when the appliance is running, the appliance will make out buzzing sound.
  • Page 14: Program Function

    “Tank” Light It comes when the water container is full, which remind you to empty the water container. “Filter”Light It comes one after each load to remind you to clean the filter. “Quick” Light The light is on after selected this programme, or its not selected. Program Function Buzz Quick...
  • Page 15  9. Fault Diagnosis Function (E1)Temperature Sensor Malfunction diagnosis (E1) (1)Condition: Temperature Sensor Malfunction or not connecting (2)System Reaction: All the selected programmes stop. Indicator lights go out. The digital tube displays fault code” E1”. All of the buttons and stall switch have no reaction. Whether the Buzzer is on or not, it will raise the Error alarm for 5 seconds every 5 minutes.
  • Page 16: Malfunction Code

    Selection procedure error diagnosis (1)Condition ①Under the state of programme selected, the system selects programme which is not selected. ②Stall switch changes switch during normal operation. (2)system reaction The digital tube displays fault code “Ers”, then it displays the setting time or the time rest.
  • Page 17: Breakdown Maintenance

    11 Breakdown Maintenance  fault Malfunction indicator Possible Cause Solution light 1、 whether the sensor is 1、replace the sensor malfunctioning? Temperature 2、re-plug in 2、 Is the plug plugged in Sensor CTN 3、replace the wire firmly? 3、 Is it short-circuit? heating wire 1、...