Rikaline GPS-6033 User Manual page 18

Bluetooth gps
Hide thumbs Also See for GPS-6033:
Table of Contents

Advertisement

Next Generation GPS
Bluetooth GPS
Within 3 months
Within 1 year
C.4.2 Testing Data
Electrical Characteristics
NO
ITEM
Complete
Charge the battery with 1c of constant current and 4.2V
1
Charge
constant voltage for 2.5 hours.
Nominal
Measure discharge capacity with discharge current 0.2C to 2.75V
2
Capacity
cut-off within 1 hour after complete charge.
Measure the capacity after 300 cycles of complete charge
3
Cycle Life
and discharge at 1C current to 2.75V cut-off
Capacity after 30days storage at 25 ℃ from complete
4
Storage
charge
Capacity after 7days storage at 60 ℃ ffom complete charge
Environmental Characteristic
NO
ITEM
Measure capacity with constant discharge current 1C to 2.75V
cut-off at each temperature after complete charge at 25 ℃ .
Temperature
1
testing
Percentage as an index of the capacity compared with
100% at 25 ℃ .
Constant
Keep the battery at 40 ℃ and 90%RH for 96hrs
2
temperature
/humidity
The battery will be vibrated 10 times in three mutually
perpendicular directions with amplitude of 0.35mm and
3
Vibration
changing frequency between 10 and 55Hz. The rate of
scanning frequency is from 10Hz to 55Hz with the rate of
1Hz per min.
Impacting
The battery will be impacted 1000±10 times with the
4
Testing
acceleration of 100m/s
The battery will be dropped free five times in three mutually
5
Free fall
perpendicular directions from the height of 1.0m onto a
hard board with the thickness of 20mm
Safe Characteristic
NO
ITEM
The battery is to be short-circuited by connecting the
positive and negative terminals of the battery with and
1
Short Circuit
external load of less than 50
Over charge
2
According to the method of UL
testing
Over
After complete charge, the battery will be discharged to end
3
discharge
voltage. Then Connect with external load of 30 Ω for 24hrs.
testing
C.4.3 Cautions
1) The best operating performance is between -20 ~ +60 °C. Higher or lower temperature could cause
damage to the battery.
2) Operated with external power supply will not hurt battery life since battery does not discharge. Therefore, it
operating temperature range is -40 ~ +85°C.
3) Recharge the battery for 10 hours before use.
Rikaline
International Corp.
Tel: ++886 2 2370 4688
Fax: ++886 2 2370 4686
All manuals and user guides at all-guides.com
GPS-6033 Operating Manual
-20~+45 °C*
-20~+25 °C*
TESTING INSTRUCTION
TESTING INSTRUCTION
2
and pulse lasting time 16ms.
TESTING INSTRUCTION
m
Ω
10F, 64, Kang-Ding Road, Taipei 108, Taiwan
E-Mail: info@rikaline.com.tw
Rikaline
REQUIREMENTS
950mAh
80% of initial Capacity
y
Retention capacit
Recovery capacity ≧
REQUIREMENTS
25% at -20 ℃
60% at 0 ℃
100% at 25 ℃
96% at 60 ℃
Recovery capacity ≧
The
battery
shall
rupture, smoke, catch fire,
vent or leak.
REQUIREMENTS
The
battery
shall
rupture, smoke, catch fire,
vent or leak.
Web: www.rikaline.com.tw
90%
90%
85%
not
not
18

Advertisement

Table of Contents
loading