External ETAtouch
Control panel
Installation

Advertisement

Table of Contents
loading

Summary of Contents for eta External ETAtouch

  • Page 1 2017-07-20 0000000386 V.001 939034-001 External ETAtouch Control panel Installation...
  • Page 2 ETA Heiztechnik Gewerbepark 1 A-4716 Hofkirchen an der Trattnach Tel: +43 (0) 7734 / 22 88 -0 Fax: +43 (0) 7734 / 22 88 -22 info@eta.co.at www.eta.co.at...
  • Page 3: Table Of Contents

    Contents General information ..............4 Installation .
  • Page 4: General Information

    Properly dispose of parts which are no longer required. All parts which are no longer required must be disposed of properly and not sent back to ETA. Only parts which are still subject to warranty or guarantee claims are to be returned to ETA.
  • Page 5: Installation

    Installation Control panel with concealed housing Installation Assembly and installation only by qualified Unscrew the screw and remove the control panel to specialist personnel prevent it from being damaged during assembly. The assembly and installation may be performed by specialist personnel with the corresponding qualifications only.
  • Page 6 Run the CAN bus wire and the network cable (if available) down to the control panel. Cover the concealed housing properly prior to any plastering or filling work. Insert the control panel and tighten the screw again. www.eta.co.at...
  • Page 7: Control Panel With Surface-Mounted Housing

    Installation Control panel with surface-mounted housing Control panel with surface- Run the CAN bus wire and the network cable (if available) down to the control panel. mounted housing Mounting the control panel on the flush-mounted junction box It is possible to mount the control panel on a flush- mounted junction box (not included in delivery scope).
  • Page 8: Can Bus Installation

    [Software Version] button. The node number the end of the CAN-Bus . If both CAN-Bus set is displayed in the overview. terminals are allocated, the terminal resistor must be removed on this circuit board. Fig. 2-2: Overview (up to X.35.X) www.eta.co.at...
  • Page 9 Installation CAN bus installation • Software version X.36.0 and later 6. Reattach the CAN-Low (CL) wire. On the control panel, open the system settings and press the [Version overview] button. The node number set is displayed in the overview. 7. Restart the entire heating system. The change will only take effect after restarting.
  • Page 10 3. Press the [CAN network] button. A window appears where you can enter the desired node number. The values 0 to 7 are permitted for the node numbers. 4. Restart the entire heating system. The change will only take effect after the restart. www.eta.co.at...
  • Page 11: Concluding Activities

    Because for You can find the files required for the software update faultless communication between the control panels, in the login area of the www.ETA.co.at website, and the same software version must be installed on all also on www.meinETA.at.
  • Page 12 The software update was successfully installed and completed when the (up to X.35.X) or symbol (X.36.0 or later) is displayed at the bottom of the screen. Install the software update on all further ETAtouch control panels in the same way. www.eta.co.at...
  • Page 13: Software Version X.36.0 And Later

    [Software update] button. If an update is 5. Enter the boiler number. available, it will appear on the screen. 6. Press [Register]. The data are transferred to ETA and the ETAtouch controller is registered for this user. 3.3.2 Software version X.36.0 and later Registering the ETAtouch controller Fig.
  • Page 14 www.eta.co.at...
  • Page 16 DOWNLOAD www.eta.co.at...