GeBe POWERMAN 8500 GR-ES Manual

GeBe POWERMAN 8500 GR-ES Manual

Inverter generator
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

POWERMAN 8500 GR-ES
ART.NR. 570752
MANUAL

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the POWERMAN 8500 GR-ES and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GeBe POWERMAN 8500 GR-ES

  • Page 1 POWERMAN 8500 GR-ES ART.NR. 570752 MANUAL...
  • Page 2: Table Of Contents

    Norsk INTRODUKSJON INNHOLDSREGISTER Gratulerer med valget av et Gebe Powerman Introduksjon ..........2 aggregat. Vi anbefaler at du leser manualen nøye Sikkerhetsinformasjon ........2 før du bruker dette aggregatet, og fullt ut forstår Sikkerhetsinformasjon og symboler ....2 alle krav og driftsprosedyrer som gjelder. Hvis du Sikkerhetskrav ..........
  • Page 3: Sikkerhetskrav

    Norsk PRODUKTOVERSIKT Ikke fyll drivstoff i nærheten av åpen flamme, sigaretter o.l. Hold produktet rent og unngå å søle olje, bensin og andre kjemikalier på produktet. Slå av aggregatet ved påfylling av drivstoff. (“OFF”) Sørg for at barn og kjæledyr ikke kommer i nærheten av aggregatet under bruk.
  • Page 4: Kontrollfunksjoner

    Norsk KONTROLLFUNKSJONER STARTBRYTER CHOKE Chockhendelen sørger for å tilføre mere drivstoff ved oppstart av kald motor. Skyv chockhendelen sakte tilbake til ÅPEN posisjon etter at motoren har startet. SNORSTART For å starte motoren, dra startsnoren sakte til deg til du kjenner motstand (kompresjonsnivået), trekk deretter snoren hurtig til deg.
  • Page 5: Tilkobling Av Elektrisk Utstyr 230V

    Norsk JORDINGTERMINAL Jordingsterminal (1) er forbundet med ikke strømledende metallkonstruksjon, samt jordpunkt i stikkontakten. For å sikre mot kortslutning og elektrisk støt fra eventuelt tilkoblet utstyr kobles jordkabel mellom terminal og jordpunkt (f.eks. jordspyd). JORDINGTERMINAL For å sikre mot kortslutning og elektrisk støt fra VARSLINGSYSTEM FOR OLJENIVÅ...
  • Page 6: Batterilading

    Norsk BATTERILADING Aggregatet har 12V uttak for batterilading. Ved bruk, start motoren først, koble deretter ladekablene til batteriet: • Koble positiv rød (+) ladekabel til positiv (+) på batteriet • Koble negativ sort (-) ladekabel til negativ (-) på batteriet OVERBELASTNIGSVERN Overbelastningsvernet vil løse ut ved overbelastning av DC-kursen (dersom batteriet trekker for mye...
  • Page 7: Før Oppstart

    Norsk FØR OPPSTART MOTOROLJE Motorolje er helt avgjørende for aggregatets ytelse og levetid. Ikke-syntetiske olje, samt olje for 2-takts motorer er ikke anbefalt og kan føre til skade på motoren. Sjekk alltid oljenivået før oppstart av aggregatet. Dette gjøres med motoren av og med aggregatet plassert på...
  • Page 8: Stoppe Motoren

    Norsk til du kjenner motstand. Trekk deretter snoren NOTICE hurtig til deg. Ikke hold startbryteren i START posisjon i mere enn 7. Sett chokehendelen i posisjon ÅPEN når 5 sekunder da dette kan skade startmotoren. Om du aggregatet/motoren blir varm. ikke får start på...
  • Page 9: Vedlikehold

    Norsk VEDLIKEHOLD Godt vedlikehold er vesentlig for sikker, økonomisk og problemfri drift av strømaggregatet. Generelt periodisk vedlikehold som oljeskift på motor, rengjøring/utskiftning av luftfilter etc., vil bidra til å forlenge aggregatets levetid. Dette er de viktigste punktene for periodisk vedlikehold forklart på de følgende sidene. Periodisk Oppgave Daglig...
  • Page 10 Norsk OLJESKIFT 1. Fjern klipset og åpne luftfilterdekselet. Sjekk om Skift olje mens motoren er varm for å sikre rask og luftfilterelementet er inntakt og rent. fullstendig tømming. 2. Om det er skittent skal elementet rengjøres. Vask 1. Ta ut peilepinnen og skru ut oljetappeplugg for å elementet i såpe og varmt vann og skyll det godt tappe oljen.
  • Page 11: Lagring

    Norsk 1. Fjern tennplugghetten. tennpluggen på plass. 2. Bruk en tennpluggnøkkel til å skru ut tennpluggen. 4. Dra forsiktig i startsnoren til du møter motstand. 3. Sjekk om isolasjonen på tennpluggen er skadet. I denne posisjonen er både innsugings- og Om den er skadet må...
  • Page 12: Tekniske Data

    Norsk TEKNISKE DATA MODELL 8500 GR-ES GENERATOR Frekvens 50 Hz Spenning 230V Maks. effekt 8,5 kW Kontinuerlig effekt 8,0 kW Faktor MOTOR Motor modell R500-V Motor type Luftkjølt, 1-sylindret, 4-takts, OHV bensinmotor Sylindervolum 500 cc Drivstoff Bensin Tankkapasitet 028 liter Driftstid v/kont.
  • Page 13 Norsk...
  • Page 14: Introduction

    English INTRODUCTION CONTENTS Congratulation on your selection of a Gebe Introduction ..........14 Powerman generator. We recommend that the Safety information ........14 operator read this manual carefully before using this Safety information and symbols......18 generator, and fully comprehend all requirements Special Requirements ........15...
  • Page 15: Special Requirements

    English COMPONENT IDENTIFICATION Don’t add fuel near the flammable thing or cigarette. Keep the machine clean and avoid spilt combustibles including gasoline on it. Turn the generator “OFF’’ when add fuel. Keep children and pets away from the area of operation.
  • Page 16: Control

    English CONTROL GENERATOR SWITCH CHOKE LEVER The choke lever is used to provide an enriched fuel mixture when starting a cold engine. Slowly put the choke lever to “OPEN” position after the engine is started. RECOIL STARTER To start the engine, pull the starter grip lightly until resistance is felt, then pull briskly NOTICE Do not allow the starter grip to snap back against the...
  • Page 17: Alternating Current (Ac) Connection

    English GROUND TERMINAL This ground terminal is dedicated to reliably grounding the whole generator. OIL ALERT SYSTEM The oil alert system is especially designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. When the oil level GENERATOR GROUNDING in the crankcase fall down below the safe limit, the To prevent electrical shock or misuse from faulty...
  • Page 18: Safety Information And Symbols

    English DC CURRENT The DC terminals are used to provide power supply for lower-power DC loads and charging other batteries. The terminals are colored as such:red to identify the positive (+) terminal and black to identify the negative (-) terminal. Load connection method: The load must be connected to DC terminals with the proper polarity (load’s positive to positive of DC terminal.
  • Page 19: Starting The Engine

    English PRE-OPERATION CHECK ENGINE OIL Engine oil is a major factor affecting engine performance and service life. Non-detergent and 2-stroke engine oils will damage the engine and are not recommended.Check the oil level before each use with the generator on a level surface with the engine stopped.
  • Page 20: Stopping The Engine

    English 7. Turn the choke lever to the“OPEN” position after NOTICE the engine is warm. Turn the GENERATOR switch to electric position and 8. Don’t use electric apparatus before setting circuit hold for more than 5 seconds or damage may be breaker to the“ON”...
  • Page 21: Maintenance

    English MAINTENANCE The engine must be properly maintained to ensure its operation be safe, economy and trouble-free, as well as eco-friendly. In order to keep your gasoline engine in good working condition, it must be periodically serviced. The following maintenance schedule and routine inspection procedures must be carefully followed. Item Task Each time...
  • Page 22 English ENGINE OIL CHANGE 2. If the air cleaner element is dirt, please clean Drain the oil while the engine is warm to ensure it: Wash the air cleaner element in a solution of complete and rapid draining. household detergent and warm water, then rinse 1.
  • Page 23: Storage

    English SPARK PLUG SERVICE WARNING Recommended spark plugs: F7RTC or other Gasoline is extremely flammable and is explosive equivalents. under certain conditions. Drain fuel in a well ventilated area with the engine stopped. Never smoke or allow flames or sparks in the area during this procedure.
  • Page 24: Specifications

    English SPECIFICATIONS MODEL 8500 GR-ES GENERATOR Frequency 50 Hz Rated Voltage 230V Maximum Output Power 8,5 kW Rated Output Power 8,0 kW Factor MOTOR Gasoline Engine Style R500-V Gasoline Engine Type Air-cooled,4-storke, OHV, single cylinder Displacement 500 cc Fuel Bensin Fuel Volume 28 liter Continuing Time...
  • Page 25 English...
  • Page 26 English...
  • Page 27 English...
  • Page 28: Garanti

    Bekrefter at dette produktet er i samsvar med følgende direktiver og standarder Intygar att denna produkt överensstämmer med kraven i följande direktiv och standarder Product.. Inverter generator / Strømaggregat / Elverk Model ..Gebe 570752 / 8500 GR-ES Machinery Directive EN ISO 8528-13:2016...

This manual is also suitable for:

570752

Table of Contents