SERVICE & OPERATING MANUAL AIR OPERATED DOUBLE DIAPHRAGM PUMP B06 & X06 Metallic FDA Series 04 Series This pump is Atex approved for use in potentially explosive atmospheres Group II category 2 This pump is normally supplied with Tri-Clamp end connections See parts list for other options.
Service / Maintenance Log Date Details Completed RECYCLING Many components of BLAGDON air operated double diaphragm pumps are made of recyclable materials. We encourage pump users to recycle worn out parts and pumps whenever possible, after any hazardous pumped fluids are thoroughly flushed. Contact Information Contact Phone / Fax No.
GA Drawing & Performance Curve General Assembly :- B06 FDA Metallic pump, all dimensions +/- 1mm B06 Metallic Pump Performance Curve, performance based on water at ambient temperature. HG-CF-1129 Rev. F - 19.10.09 Page 3...
IMPORTANT This pump should be used in accordance with the requirements of the Health and Safety at Work Act 1974. All business conducted subject to Blagdon Pump. Terms and Conditions of Sale, available on request. LAMBERT ROAD,ARMSTRONG, WASHINGTON, TYNE & WEAR NE37 1QP, ENGLAND.
Your BLAGDON PUMP is a high simultaneously exhausting the other inner body. This simultaneously sends inlet pressure performance unit capable of achieving chamber. This causes the diaphragms, which are to the opposite chamber.
Important Warnings and Safety Information IMPORTANT Read these safety warnings and instructions in this manual completely, before installation and start-up of the pump. It is the responsibility of the purchaser to retain this manual for reference. This manual must be kept with, and supplied with the pump at all times.
TROUBLE SHOOTING GUIDE NOTE :- Check all solutions before dismantling the pump. PROBLEM CAUSE SOLUTION Pump will not start Air valve assembly malfunction/Seizure Check carrier for freedom of movement. - Clean, oil & replace. Obstructed fluid line. Clean line or increase line size. Obstructed diaphragm chamber.
IMPORTANT! the valve system to malfunction. R E P L A C I N G D I A P H R A G M S Remove both suction and discharge Read these instructions Re-assemble valve block manifolds as detailed in the previous c o m p l e t e l y , b e f o r e assembly &...
EXHAUST SAFETY WHEN PUMPING HAZARDOUS LIQUIDS WARNING! In the event of diaphragm rupture, pumped material may enter the air end of the pump, and be discharged into the atmosphere. If pumping a product which is hazardous or toxic, the air exhaust must be piped to an appropriate area for safe disposition. Flooded Suction Installation Submerged Installation Suction Lift Installation...
PARTS LIST PARTS LIST - cont. REF. PART No. DESCRIPTION PART DESCRIPTION NUMBER 06-207 BASE LEG THE FOLLOWING PARTS ARE USED ON ATEX CERTIFIED PUMPS (see page 7) D274 SKT C’SUNK SCREW M3 x 10 SA10289 GROUNDING LEAD ASSY. G258 O-RING SP467 ATEX I/D TAG...
Need help?
Do you have a question about the B06 and is the answer not in the manual?
Questions and answers