Mianyang Weibo Electronic WB5110-D User Manual

Mianyang Weibo Electronic WB5110-D User Manual

Multifunctional harmonic meter

Advertisement

Quick Links

Mianyang Weibo Electronic Co., Ltd
www.wb-my.com wbwm@wbdz.cn
86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile)
Technical Consultant Tel: 86 816 2278271
USER MANUAL
WB5110-D
Multifunctional Harmonic Meter
Thank you for choosing WB5110-D Multifunction Harmonic Meter! Wish you a pleasant experience of
using WB5110-D!
If there is any damage found in the the package or surface of the meters, please contact us or distributor
immediately!
To avoid some problems generated from inappropriate operation of this meter, please read this manual
carefully before installation.
-0-

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WB5110-D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mianyang Weibo Electronic WB5110-D

  • Page 1 WB5110-D Multifunctional Harmonic Meter Thank you for choosing WB5110-D Multifunction Harmonic Meter! Wish you a pleasant experience of using WB5110-D! If there is any damage found in the the package or surface of the meters, please contact us or distributor...
  • Page 2 Technical Consultant Tel: 86 816 2278271 Safety Claim This user manual is only used for description of WB5110-D multifunctional Harmonic Meter. Please read this manual carefully before installation, operation or repairing. In this user manual, it is assumed that every one who would be associated with this product should be familiar with the contents of the safety section, or this safety guide and basic electrical engineering knowledges.
  • Page 3: Table Of Contents

    Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Table of Content Safety Claim....................错误!未定义书签。 2. WB5110-D Introduction .......................4 2.1 Overview ..........................4 2.2 Features ..........................4 2.3 Plug-In Selectrion Table......................4 2.4 Structure &...
  • Page 4 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 6.4.3.2 Sketch Drawing of Parameters Programming ............31 7. Noticed Items ....................错误!未定义书签。 8. After Sales...........................43 8.1 New Product Guarantee ....................43 8.2 Warranty..........................43...
  • Page 5: Overview

    WB5110-D is easy to be installed, wiring and maintained. And its input parameters can be programmed at working field site.
  • Page 6: Structure & Working Principle

    1-channel Reactive Enery Pulse Output Be Noticed: 1. One unit of WB5110-D has maximum 4 Plug-In modules; 2. Energy Pulse Plug-In must be plugged in the 4 channel; 3. Each type of Plug-In has configured maximum numbers are showed in the Above Table 1;...
  • Page 7: Technical Dtasheets

    Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 limit alarmingdata, remote transmitting and structuring working net with host computer through RS485 interface. 2.5 Technical Datasheets Single Phase;...
  • Page 8 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Contact Point Capacity: AC 250V/2A; DC 30V/2A Alarm thresh-hold value, postponed time and switching gap can be programmed through RS485 Interface and press buttons;...
  • Page 9: Installation And Operating

    Graphic 1: Outline Size Drawing 4. Installation and Operation 4.1 Installation WB5110-D Multifunctiona Harmoinc Panel Meter is suitable for embedded installation. The installation panel dimensions is 92mm*92mm; When panel size is ready then embed the meter into the panel slot for sure.
  • Page 10 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Graphic 2 Main Part Terminals Channel - 1 Channel-4 4.2.1 Terminals Instruction No. of Identificaqtion Definiton Identification Definition...
  • Page 11 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 4.2.2 Plug-In Instruction Plug-In Module 1 Module 2 Module 3 Module 4 Graphic 3 Plug-In Schematic Drawing Plug-In Module Instruction :...
  • Page 12: Input Signal Wiring

    Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 4.2.3 Input Signal Wiring 14 11 12 11 单相 三相三线 电压直接接入 Single Phase 3 Phase 3 wire Voltage Connected In...
  • Page 13: Analogue Output

    Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 4.2.5.2 Energy Pulse Output 电能脉冲输出模块 Energy Pulse Output Module 4.2.5.3 Analogue Output Module 65 66 67 68 61 62 63 64 模拟量输出模块2...
  • Page 14 Technical Consultant Tel: 86 816 2278271 4.3 Wiring Instruction Auxilairy Power Supply is needed for normal operation of WB5110-D. Please make sure using specs of right auxiliary power supply to protect the meter from damage. Please be noticed the rated input voltage shall not be more than the meter required input voltage, otherwise should consider using PT, and PT secondary one end should be grounded.
  • Page 15 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 If choose switch input status as alarming output, there is no need to set alarming threshold value. It can be through programming relay output as “switch”.
  • Page 16 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Analogue output Plug-In module: There are 34 electric parameters stored in the real time measurement register table list, and every channel can choose one electric parameter to configure.
  • Page 17 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 6. Panel Operation and Display Introduction 6.1 Panel Introduction Graphic 4 Panel Indication Diagram 6.2 Displaying Area Introduction...
  • Page 18: Menu Operation

    Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Promt Real Time Data Display Zone Frequency Prompt Real Time Data Unit Total Value Prompt Current Percentage Column...
  • Page 19: Data Inquiry List

    Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Graphic 5 Structural Diagrams 6.4.1 Data Inquiry 6.4.1.1Data Inquiry Table List This device supports the systems of 3 -phase 4 -wire, 3- phase 3- wire and single phase.
  • Page 20: Data Inquiry Process

    Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Reverse Active Energy Reverse Active Energy Reverse Active Energy 3:Line Voltage + Frequency + Forward 3 : Line Voltage + Frequency + 3 :...
  • Page 21 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Line Voltage + Average Line Voltage: Phase Voltage + Average Phase Voltage: : Phase Voltage + Zero Sequence Voltage:...
  • Page 22 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Continue Press , It Shows: Phase Current + Zero Sequence Current: Phase Current + Average Current: Continue Press...
  • Page 23 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 3 phase Apparent power + Total Apparent Power: 3 phase power factor + Total Power Factor: Continue Press 按...
  • Page 24 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Current Maximum Value + Time Total Active Power Maximum Value + Time: Total Reactive Maximum Value + Time:...
  • Page 25 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Voltage Minimum Value + Time: Current Minimum Value + Time: Total Active Power Minimum Value + Time:...
  • Page 26 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Total Reactive Power Minimum Value + Time: Total Apparent Power Minimum Value + Time: Press ,Harmonic Display Interface Voltage THD:...
  • Page 27 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 I times of voltage harmonic: …… Voltage Harmonic: 1times of current harmonic: …… -26-...
  • Page 28 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 current harmonic: Continue Press , Its Shows: 3 phase Line Voltage + Frequency+ Forward Active Energy: 3 phase current + Average Current + Reverse...
  • Page 29 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 3 phase Current + Average Current + Reverse Reactive Energy: 3 phase line voltage + Frequency + Apparent...
  • Page 30: Pin Code Input

    Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 3 Phase Line Voltage + Frequency + Time: 6.4.2 PIN Code Input On the interface of data inquiry, long press PROG for 3 seconds, then enetered into PIN Code Input interface.
  • Page 31 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Types System Type(NET) Voltage Measurement Range(VRAG) Current Measurement Range(IRAG) No. of PT、CT、CT(CTNO) Active Pulse Constant(APUL) Reactive Pulse Constant(RUPL)...
  • Page 32 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 All Data Zero Clearing (ALL) 6.4.3.2 Parameters Programming Diagram Operation Setting , choose 4NBL (3-phase Press system(NET)seting: 4-wire);...
  • Page 33 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 PT Ratio(PT)setting: Press , Cursor Left Move/ Cursor Right Move; Press , Decrease / Increase parameter’s value;...
  • Page 34 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Pulse Constant based on the 100 times to increase or decrease. When product’s specifications are 57.7V、 1A or 100V、...
  • Page 35 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Press Back to the main menu. Lose Phase Setting(LOSE): Press , left move / right move cursor;...
  • Page 36 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Date Setting(DATE): 17. Press , left move / right move cursor; 18. Press , Decrease/ increase parameter value;...
  • Page 37 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Pin Code Setting (CODE): 25. Press , left move / right move cursor; 26. Press , Decrease/ increase parameter value;...
  • Page 38 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 The First Channel Alarm Type Setting (ALTP) : 1、 Press Select HAL(High Alarm) LAL(Low Alarm) HLAL(High or Low Alarm) INAL(Switch Input Alarm) REMT(Romote Transmitting);...
  • Page 39 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 The first Channel Alarm Lower Limit Value 37. Press , left move / right move Setting(ALLO): cursor;...
  • Page 40 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 The first Channel coverting & transform Object 1、 Press , Select Converting and Setting(S1OB): transform Object. 2、 Press confirm modification, Cursor Disaapears;...
  • Page 41 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 The First Channel High Value Setting(S1HP) : 53. Press , left move / right move cursor; 54. Press , Decrease/ increase parameter value;...
  • Page 42 Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 clear(DMND) : 3、 Press ,select YES、NO; 4、 Press modification confirmed; cursor disappeared; 1、 Press back to main menu clear(MOST)...
  • Page 43: Noticed Items

    Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 Clear SOE(SOE) : 9、 Press ,select YES、NO; 10、 Press revise confirmed; cursor disappeared; 1、 Press back to main menu Clear (ALL)...
  • Page 44: Packaging

    Mianyang Weibo Electronic Co., Ltd www.wb-my.com wbwm@wbdz.cn 86 816 2971265 (office) /86 816 2281934 (Fax)/86 18980129532 (Mobile) Technical Consultant Tel: 86 816 2278271 8. Aftersales Services 8.1 Product Quality Gurantee All sold new products will be covered by one year’s quality gurantee. Due to the defective design, or material using and manufacturing, the meter can be returned and exchanged at free cost to the supplier.

Table of Contents