Summary of Contents for Franklin Electric E-Tech GD Series
Page 1
Ed. 01 Rev. 00 Data: 01/04/19 PR. T : FG018572 USE AND INSTALLATION MANUAL BOOSTER SETS WITH VARIABLE SPEED by frequency inverter for each pump...
TABLE OF CONTENTS Declaration of conformity page………3 Warning and safety page………4 Description page………5 Generality page………6 Working limits page………7 Installation page………8 Electric connections page……….9-11 General features page……….12-13 Run commissioning page………. 13 10. Hydraulic scheme page………. 14 11. Troubleshooting page………. 14 12. Dangerous areas page……….
DECLARATION OF CONFORMITY The manufacturer: E-Tech Via Asolo, 7 - 36031 Dueville (Vicenza) DECLARES UNDER ITS RESPONSIBILITY THAT THE BOOSTER SET: MACHINE NUMBER MODEL HEAD FLOW RATE MAXIMUM HEAD MAXIMUM FLOW RATE ENGINE RPM VOLTAGE-FREQUENCY TEST DATE POWER it’s conforms to the Essential Safety and Health Requirements of the following European Directives: MACHINE DIRECTIVE (2006/42/CE) 2014/30/UE Regarding Electromagnetic Compatibility...
2. WARNINGS AND SAFETY The symbols illustrated below, together with “DANGER” or “WARNING”, indicate the potential risks due to the inobservance of the instruction to which they have been related, as indicated below: Warns that there is a risk of electric shock if the DANGER, instructions are not observed RISK OF ELECTRIC...
3. DESCRIPTION Booster sets designed and built to ensure a constant pressure, specifically suitable for domestic applications and small or medium systems for civil, agricultural or industrial uses. Booster sets strengths and benefit: constant pressure, low noise operation, low running costs, low water consumption, protection against dry running. Is recommended to use the sets with membrane pressure tanks.
4. GENERALITY The present manual is aimed at giving the necessary information regarding the installation, use and maintenance of booster sets with variable speed by frequency inverter installed on each pump consisting of 2 pump. It is vital that the user reads this manual prior to using the system. Improper use may cause damage to the machine as well as the lapse of the guarantee.
5. WORKING LIMITS WARNING FOLLOW PROVISIONS SAFETY PERFORM PLANNED MAINTENANCE RECOMMENDED IN THE INSTRUCTION MANUALS, AS WELL AS INDICATED: Operating ambient temperature: min. +4°C; max +40°C for internal installations (CEI EN 60439-1). Employable liquids: water free of vegetation, fibrous or other matter in suspension gas and corrosive/aggressive substances.
6. INSTALLATION DANGER RISK OF ELECTRIC DANGER WARNING SHOCK The set must be fitted in a well ventilated place, protected from unfavourable weather conditions. • When handling the set, lift it by the base. • Do not lift the set by the delivery manifold: risk of damage. •...
7. ELECTRIC CONNECTIONS DANGER RISK OF ELECTRIC DANGER WARNING SHOCK The units are delivered ready for power connection, which must be carried out by a qualified and authorized in a manner consistent with the rules in force in the country of installation. Make sure that the mains power supply is equipped with protections and for making the land compliant.
Page 10
DANGER RISK OF ELECTRIC DANGER WARNING SHOCK - versions “M/T”- Connect the power supply (single-phase After plugging in the power supply and 230Vac) to the power supply panel and connect switch the breaker operated press the the power supply panel to the inverter. Turn on START button to start the group.
Page 11
DANGER RISK OF ELECTRIC DANGER WARNING SHOCK If the request is the function COMBO, first pump must be connected to the following through a three-core cable with a minimum section 0.5mm2 exploiting the positions S +, S-and G present in the control card. (if you use the DRIVE-TECH 209,414,418,425) If the function COMBO is required with the DRIVE-TECH 214 and the DRIVE-TECH 409, the connection between the inverter (DRIVE-TECH) is carried out using a bipolar cable connected to terminals 3 and 4.
8. GENERAL FEATURES The inverter (DRIVE-TECH) is a device for the control and protection of pumping systems based on the variation of the supply frequency of the pump. It can be applied to both new and existing installations guaranteeing: • Energy and cost savings •...
you want to exclude a security from inverter (DRIVE-TECH) combined operation is necessary to disconnect the corresponding sensor, in order to prevent the inverter (DRIVE-TECH) master commands automatically START the slave of interest. In case of alarm or failure of a pump this will be replaced (temporarily or permanently depending on the type of alarm that occurred) by another group.
10. HYDRAULIC DIAGRAM example with 2pumps LEGEND Electric pump 1 Electric pump 2 Manometer Pressure transducer 1 Pressure transducer 2 Check valve Stop valve 11. TROUBLESHOOTING FAULT CHECK (possible cause) REMEDY The motor does not start. 1. Check that the pressure switch is connect.
12. DANGEROUS AREAS With the study of the risks involved in using this group, we extrapolate the following explanatory table showing a summary of the dangerous parts of the machine. possibility severity frequency Chance of danger Protective measures taken Notes Dangerous Zone exposure occurrence...
Page 16
DANGER RISK OF ELECTRIC DANGER WARNING SHOCK Fig. 2: Electropump terminal block Fig. 1: INVERTER (DrivE-Tech) open REMOVING THE PROTECTIONS REMOVING THE PROTECTION RISK INVERTER ELECTRIC SHOCK OF ELECTRIC SHOCK ELECTRIC VOLTAGE ELECTRIC CURRENT Fig. 3: Filter box open (only three phase versions) Fig.
13. DISPOSAL OF THE PRODUCT AT THE END OF USEFUL LIFE INFORMATION TO USERS pursuant to art. 14 of DIRECTIVE 2012/19 / UE OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 4 July 2012 on waste electrical and electronic equipment (WEEE) The crossed-out wheelie bin symbol on the Electronic Electrical Equipment (EEE) or on its packaging indicates that the product at the end of its useful life must be collected separately and not disposed of together with other mixed municipal waste.