Compressor auto drain - timed

Advertisement

3.2.
Mechanical
Notes: 1) An isolating valve immediately upstream of the drain valve will simplify future removal for maintenance.
2) Each condensate source must be drained separately, see fig.1.
3.2.1. Install the drain valve directly into the system condensate discharge point or as near as possible to it.
3.2.2. If remote mounting ensure that valve is below discharge point and that the pipe run will allow air bubbles to flow up from
valve to system. Connecting pipe should be of 3/8” bore, or larger. Orientate the valve within the limits shown in fig.2.
3.2.3. The outlet (fig.2.C) should be connected to a condensate drain using 8 - 10 mm bore flexible tube.
3.2.4. Bubble test joints to check for leaks.
4.
OPERATION
4.1.
When installation is complete connect valve to electricity supply via a 3 amp fuse.
4.2.
Switch on supply and the green LED (fig.3.1) will light to indicate that the unit is connected.
4.3.
Set the flow control (fig.3.4) to the required rate of drainage and operation is then
automatic, with the red LED (fig.3.2) indicating when the drain valve is open.
4.4.
Pressing the ‘Test’ button (fig.3.3) will open the drain valve to confirm that the valve is operating correctly.
fig. 2
5.
MAINTENANCE
F
WARNING! Disconnect from electricity supply and isolate from, or vent, system pressure before working on, or
removing, drain valve.
5.1.
Clean inlet filter regularly. Remove filter as shown in fig.4.
5.2.
In the event of a malfunction, which cannot be rectified by manually operating the valve via the test button, have the unit checked
by an authorised service agent.
6.
PARTS
Declaration of Conformity
We, the sole importer into the UK, declare that the
with the following standards and directives. The construction
inspected by a national authority upon request to Jack Sealey Ltd.
Compressor Auto Drain - Timed. Models: AD1 & AD2
73/23/EEC LV Directive
89/336/EEC EMC Directive
93/68/EEC CE Marking Directive
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component
parts without prior notice. IMPORTANT: No liability is accepted for incorrect use of this equipment. WARRANTY: Guarantee is 12
months from purchase date, proof of which will be required for any claim. INFORMATION: For a copy of our latest catalogue and
promotions call us on 01284 757525 and leave your full name and address, including postcode.
Sole UK Distributor,
Sealey Group,
Bury St. Edmunds, Suffolk.
fig. 4
fig. 3
Item Part No.
Description
Item Part No.
Description
1
AD1/01
Drain Regulator
8
AD1/08
Rear Case
2
AD1/02
O-Ring
9
AD1/09
Nipple
3
AD1/03
Front Case
10
AD1/10
Screw
4
AD1/04
ECB
11
AD1/11
Connector Seal
4
AD2/04
ECB
12
AD1/12
Connector
5
AD1/05
Solenoid Valve
13
AD1/13
Screw
6
AD1/06
O-Ring
14
AD1/14
Filter
7
AD1/07
Seal
‘AD1/’ part numbers apply to both models unless shown otherwise.
products
listed here
are
in conformity
files
for
these products are
held by the Manufacturer and may be
Signed by Mark Sweetman
14th July 2000
For Jack Sealey Ltd. Sole importer into the UK of
Sealey
Power Products.
E-mail: sales@sealey.co.uk
01284 757500
01284 703534
AD1 & AD2 - 1105 - (1) - 120700
3.2.
Mechanical
Notes: 1) An isolating valve immediately upstream of the drain valve will simplify future removal for maintenance.
2) Each condensate source must be drained separately, see fig.1.
3.2.1. Install the drain valve directly into the system condensate discharge point or as near as possible to it.
3.2.2. If remote mounting ensure that valve is below discharge point and that the pipe run will allow air bubbles to flow up from
valve to system. Connecting pipe should be of 3/8” bore, or larger. Orientate the valve within the limits shown in fig.2.
3.2.3. The outlet (fig.2.C) should be connected to a condensate drain using 8 - 10 mm bore flexible tube.
3.2.4. Bubble test joints to check for leaks.
4.
OPERATION
4.1.
When installation is complete connect valve to electricity supply via a 3 amp fuse.
4.2.
Switch on supply and the green LED (fig.3.1) will light to indicate that the unit is connected.
4.3.
Set the flow control (fig.3.4) to the required rate of drainage and operation is then
fig. 1
automatic, with the red LED (fig.3.2) indicating when the drain valve is open.
4.4.
Pressing the ‘Test’ button (fig.3.3) will open the drain valve to confirm that the valve is operating correctly.
5.
MAINTENANCE
F
WARNING! Disconnect from electricity supply and isolate from, or vent, system pressure before working on, or
removing, drain valve.
5.1.
Clean inlet filter regularly. Remove filter as shown in fig.4.
5.2.
In the event of a malfunction, which cannot be rectified by manually operating the valve via the test button, have the unit checked
by an authorised service agent.
6.
PARTS
Declaration of Conformity
with the following standards and directives. The construction
inspected by a national authority upon request to Jack Sealey Ltd.
Compressor Auto Drain - Timed. Models: AD1 & AD2
89/336/EEC EMC Directive
93/68/EEC CE Marking Directive
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component
parts without prior notice. IMPORTANT: No liability is accepted for incorrect use of this equipment. WARRANTY: Guarantee is 12
months from purchase date, proof of which will be required for any claim. INFORMATION: For a copy of our latest catalogue and
promotions call us on 01284 757525 and leave your full name and address, including postcode.
fig. 2
fig. 3
Item Part No.
Description
1
AD1/01
Drain Regulator
2
AD1/02
O-Ring
3
AD1/03
Front Case
4
AD1/04
ECB
4
AD2/04
ECB
5
AD1/05
Solenoid Valve
6
AD1/06
O-Ring
7
AD1/07
Seal
‘AD1/’ part numbers apply to both models unless shown otherwise.
We, the sole importer into the UK, declare that the
files
for
these products are
73/23/EEC LV Directive
For Jack Sealey Ltd. Sole importer into the UK of
Sealey
Power Products.
Sole UK Distributor,
01284 757500
Sealey Group,
Bury St. Edmunds, Suffolk.
fig. 1
fig. 4
Item Part No.
Description
8
AD1/08
Rear Case
9
AD1/09
Nipple
10
AD1/10
Screw
11
AD1/11
Connector Seal
12
AD1/12
Connector
13
AD1/13
Screw
14
AD1/14
Filter
products
listed here
are
in conformity
held by the Manufacturer and may be
Signed by Mark Sweetman
14th July 2000
E-mail: sales@sealey.co.uk
01284 703534
AD1 & AD2 - 1105 - (1) - 120700

Advertisement

loading

This manual is also suitable for:

Ad2