    Table of content 1. Change history _________________________________________________________________________________________________________2 2. Connect Mesh 4-Channel Interface ______________________________________________________________________________________4 2.1. General Information: ____________________________________________________________________________________________________4 2.2. Setup_________________________________________________________________________________________________________________4 2.3. Switching a group ______________________________________________________________________________________________________4 2.4. Dimming ______________________________________________________________________________________________________________4 2.5. Update Mode __________________________________________________________________________________________________________5 2.6. Reset _________________________________________________________________________________________________________________5 2.7. Status LED ____________________________________________________________________________________________________________5 3. Standalone Mode _______________________________________________________________________________________________________6 3.1.
  • Page 4: Connect Mesh 4-Channel Interface

    2. Connect Mesh 4-Channel Interface 2.1. General Information: The Connect Mesh 4-Channel Interface is an installation device which can be used to integrate existing wall switches from other manufacturers that are already on site into your Bluetooth® Mesh Network. Status LED Reset Button Red wire - Live Wire (L) Brown wire -Switch S4...
  • Page 5: Update Mode

    2.5. Update Mode In case the irmware is outdated, the user will be notiied in the Connect Mesh App. Then the user can start and perform the irmware update of the mesh device. (more information in the speciic Häfele Connect Mesh App). Option 1: Update via App If the Mesh device is provisioned the update can be done by: Click on Mesh device and click on edit icon and scroll down to the bottom of the page.
  • Page 6: Standalone Mode

    3. Standalone Mode 3.1. Standalone Mode with 4-Channel Interface as Provisioner To conigure a network without the App, you can use the 4-Channel Interface as the provisioner (controller). By this you can provision mesh boxes with monochrome, multi-white lights or RGB lights. Attention: Only one wall switch can be used to control the network.
  • Page 7: 4-Channel Interface Standalone Mode With Multi-White Lights

    3.1.2. 4-Channel Interface Standalone Mode with Multi-White Lights To start, the 4-Channel Interface needs to contain a irmware version of at least 4.4.6 (otherwise please update) and needs to be reset (status led blinks). Start the search for mesh boxes by pressing the upper left and lower left buttons for 4 seconds. The led will start blinking (slowly).
  • Page 8: 4-Channel Interface Standalone Mode With Rgb Lights

    3.1.3. 4-Channel Interface Standalone Mode with RGB Lights To start, the 4-Channel Interface needs to contain a irmware version of at least 4.4.6 (otherwise please update) and needs to be reset (status led blinks). Start the search for mesh boxes by pressing the upper left and lower right buttons for 4 seconds. The led will start blinking slowly.
  • Page 9: Standalone Mode With Remote Control As Provisioner

    3.2 Standalone Mode with Remote Control as Provisioner When using the Remote Control as Provisioner for the Standalone Mode, the 4-Channel Interface can be added as a provisioned device. 3.2.1. Remote Control Standalone Mode functions 4-Channel Interface The 4-Channel Interface will be added when the Remote Control is searching for new devices in the Standalone Mode.
  • Page 10: Connect Mesh 4-Channel Interface Installation Guidelines

    4. Connect Mesh 4-Channel Interface Installation Guidelines 4.1. General Information: • Connect Mesh 4-Channel Interface has 4 Channels. • These 4 Channels can be used to control Luminaire/Häfele Devices connected in Connect Mesh 6 way distributor. • Luminaire connected to Connect Mesh 6 way distributor are dimmable. •...
  • Page 11 Channel 1: Green Wire is negative terminal of Channel 1. Connect the Green wire in the 3rd slot of the GIRA Switch (Top Side) as shown in image 10. [image 10] Channel 2: Blue Wire is negative terminal of Channel 2. Connect the Blue wire in the 1st slot of the GIRA Switch (Top Side) as presented in image 11.
  • Page 12: List Of Compatible Switches

    Channel 3 Yellow Wire is negative terminal of Channel 3. Connect the yellow wire in the 1st slot of the GIRA Switch (Bottom Side) as demonstrated in image 12. [image 12] Channel 4 Brown Wire is negative terminal of Channel 4. Connect the brown wire in the 3rd slot of the GIRA Switch (Bottom Side) as shown in image 13.