Installation and Maintenance
Version 0.0 Feb. 2019
©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary.
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GENESIS DAS and is the answer not in the manual?

Questions and answers

Summary of Contents for Solid GENESIS DAS

  • Page 1 GENESIS Installation and Maintenance Version 0.0 Feb. 2019 ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 1...
  • Page 2 SOLiD reserves the right to change the contents without prior notice. In no event shall SOLiD be liable for any damages resulting from loss of data, loss of use or loss of profits. SOLiD further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period.
  • Page 3 GENESIS DAS Operation Manual - Version 0.0 – Jan. 2019 Revision History Revision Issue Date Section Changes ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 3...
  • Page 4: Table Of Contents

    LRN Front and Rear Panel .................... 20 4.1.3.1 Front Panel ......................... 20 4.1.3.2 Rear Panel ........................20 4.1.4 LRN Installation......................21 System Operation ....................28 LRN Parameters ......................... 28 FCC/IC User Warning .................... 30 ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 4...
  • Page 5 Figure 4.4 LRN Rear Panel View ........................ 20 Figure 4.5 LRN Installation Clearance ......................21 Figure 4.6 LRN Power Cabling ........................24 Figure 4.7 LRN SFP Ports .......................... 25 ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 5...
  • Page 6 HOU Digital Transceiver Unit HOPSU HOU Power Supply Unit HOFAN HOU FAN EPSU Expansion Power Supply Unit Low power Radio Node RN Base Unit LPMU LRN Power Amplifier & Multiplexer Unit ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 6...
  • Page 7: Safety & Certification Notice

    “Only qualified personnel are allowed to handle this unit. Read carefully and understand all the warning labels attached in this user manual” Any personnel involved in installation, operation or service of the SOLiD repeaters must understand and comply the following: Understand all general and regional installation and safety regulations relating to work on high ...
  • Page 8 Rotating fan Blade Can cause serious injury or pain. Keep hands clear. Turn off and lock-out unit before servicing. AUTION Do Not Open Except at Approved Field Force Protective Work Station. ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 8...
  • Page 9: System Overview

    The head-end unit must always be connected to the Base Station using a direct cabled connection. This system has not been approved for use with a wireless connection via server antenna to the base station. ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 9...
  • Page 10 Embedded DMS, server DMS and cloud EMS  High-quality user experience(visibility, intuitive troubleshooting, auto commissioning, and  reports)  Single EMS for managing LRN  Automatic node discovery Easy-set   Flexible power splitting ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 10...
  • Page 11: System Overview

    Low Power Radio Node (LRN): Receive signal and power via optical cable and power cable (supported AWG 14 to 24) from HOU The following shows GENESIS network topology. Figure 2.1 GENESIS Network Topology ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 11...
  • Page 12: System Capacities

    Main DAU can drive up to sixteen (16) HOUs  HOU can drive up to eight (8) LRNs via optical cables.  LRN can support up to six (6) RF band modules.  ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 12...
  • Page 13: System Specifications

    90 ~ 264VAC -42 ~ - 56VDC 264VAC IP20 or IP66 IP Rating IP20 IP20 IP20 IP20 IP20 (OPTION) Cooling FAN Forced FAN Forced Natural FAN Forced Natural Forced ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 13...
  • Page 14: Downlink Specifications

    Unwanted Emission Spurious Emission Category B > 35dB @ Fc±5MHz ACLR UMTS > 35dB @ Fc±5MHz < 3.5% 256QAM UMTS < 12.5% CDMA < 0.912(Rho) < 5°(phase error), < 20°peak(RMS) ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 14...
  • Page 15: Uplink Specifications

    Simplex port -35dBm/total Duplexed port 30dB System Gain RN to DAU Simplex port 10dB Gain Control 0 ~ 50dB < 8% 64QAM UMTS < 12.5% Noise Figure < 14dB ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 15...
  • Page 16: System Configuration And Functions

    The LRN is active modular and multi-band upgradeable antenna unit. It supports four (2) sub-modules which are replaceable in a SOLiD certified facilities by SOLiD certified personnel. The mix of service bands can be achieved, for example, six (6) different bands are available. The composite RF power per band is 15dBm(below 1GHz), 20dBm(upper 1GHz) and 17dBm(2300W Band).
  • Page 17: Lrn Functions And Description

    10Gbps over an optical cable External antenna ports available  IP20 rated and optional IP66 supported  Wall or ceiling mounting options   256 QAM supported OMPONENT ESCRIPTION Figure 4.2 LRN Appearance ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 17...
  • Page 18  Control and monitoring system status  Amplify downlink RF signal and then filter the signal LPMU  Filter and amplify uplink RF signal  Support external antenna port ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 18...
  • Page 19 UL Input Power Max. -38dBm w ALC function Nominal Impedance 50ohm VSWR 1.8:1 Type of External Antenna Port SMA_F System Ripple ±2dB UL ALC Control Range/step 0 ~ 20dB/0.1dB ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 19...
  • Page 20: Lrn Front And Rear Panel

    LRN is normal ② Power is not activated HOU(SFP+) Port connected to the HOU to transmit / receive data ③ DC IN Port receiving DC 57V from HOU or EPSU ④ ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 20...
  • Page 21: Lrn Installation

    The clearance might be increased depending on the flexibility of cable. Figure 4.5 LRN Installation Clearance There are two LRN installation mount brackets as shown below. Quick-lock Mounting Bracket Ceiling Mounting Bracket ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 21...
  • Page 22 (*The mounting bracket set has the special structure to prevent the LRN from falling. Please consider it when you need to remove the LRN from the wall bracket.) ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 22...
  • Page 23 3. Adjust the ceiling mount to the ceiling frame interval you want to install. 4. Tighten the ceiling frame with M4 and M6 screws in the screw hole of the ceiling mount. ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 23...
  • Page 24: Figure 4.6 Lrn Power Cabling

    Figure 4.6 LRN Power Cabling The recommended power cables (AWG 14 to 24) is dependent on each country. User can seek easily in the market. ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 24...
  • Page 25: Figure 4.7 Lrn Sfp Ports

    Inspect and clean the fiber tips, coupler, and connectors.   Prepare and clean an external attenuator, if needed When handling fiber cables, take the following precautions to prevent damage to the cable: ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 25...
  • Page 26 LRN’s SFP cage direction is horizontal type. So user install SFP module horizontally to optical port like below. 1. SFP optical port 2. SFP transceiver 3. Fiber optic cable 4. SFP handle User should use optical fiber cable based on SFP type (only duplexer). ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 26...
  • Page 27 DAS Operation Manual - Version 0.0 – Jan. 2019 The following shows optical fiber based on SFP type SFP Types Optical fiber Connector/Ferrule type Remark LC/UPC SFP-10G-SR 2 optical fiber ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 27...
  • Page 28: System Operation

    LPMU is installed at the LRN. Its LPMU can be hot pluggable. Whenever LPMU installed, LRN system detect that LPMU type and can set up the parameters of LPMUs. ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 28...
  • Page 29 GENESIS DAS Operation Manual - Version 0.0 – Jan. 2019 ① Band information ② DL Output power ③ DL/UL Amp on/off ④ UL Input power ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 29...
  • Page 30: Fcc/Ic User Warning

    (p.i.r.e.) ne dépassepas l’intensité nécessaire à l’établissement d’une communication satisfaisante. . 7.1.2 – ( RSS-GEN, S DETACHABLE ANTENNAS ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 30...
  • Page 31 20 cm entre la source de radiation (l’antenne) et toute personne physique. Cet appareil ne doit pas être installé ou utilisé en conjonction avec une autre antenne ou émetteur. (Max. antenna gain : DL 5 dBi) ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary. Page 31...
  • Page 32 FCC Booster warning Part 90 and Part 20 Signal Boosters. THIS IS A 90.219 CLASS B DEVICE WARNING. This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this have an FCC LICENSE or express consent of an FCC Licensee to operate this device.