Table of Contents

Advertisement

SET TIME
- Increase Cleaning Time Period
o
Press + Time Key once and release to increase time period by 1-minute increments
o
Hold + Time Key in to increase time period by 10-minute increments
- Decrease Cleaning Time Period
o
Press - Time Key once and release to decrease time period by 1-minute increments.
o
Hold - Time Key in to decrease time period by 10-minute increments.
• When done, press the HEAT Button [A] - Press this button to STOP HEATING. the BLUE LED
will go out.
DO NOT touch parts or solution at this point as they will be hot and can cause
burns!
• Leave Unit Power Switch "ON" to allow the LED Temperature to display the cleaning fluid
temperature. The Lid may be removed to speed cooling. DO NOT touch parts or fluid until it has
cooled to a safe level.
• When cooled sufficiently, set the Unit Power Switch to "OFF"
• Grasp the Basket by the handles and slowly remove it allowing excess fluid to drain into
the Tank.
DO NOT allow excess cleaning fluid to drip onto controls or display!

DRAIN TANK

• Unplug Power Cord from the power source and remove the Power Cord from the receptacle at
the rear of the Cabinet.
DO NOT attempt to drain the unit with the Power Cord plugged into the power
source!
• Wearing Suitable chemical resistant gloves
and eye splash protection, slowly open
the Drain Valve (FIG 6) and allow the used
cleaning fluid to drain into an approved
container of the appropriate capacity.
Used cleaning fluids are haz-
ardous materials and should
be disposed of in compliance
with local regulations.
10
BURN HAZARD!
SHOCK HAZARD!
Eastwood Technical Assistance: 800.343.9353 >> tech@eastwood.com
FIG. 6