The TEST mode commands the control station to beep continuously and light the
corresponding zone indicator, each time a zone is violated. The zone indicator of
each tested zone will remain lighted while each succeeding zone is tested. Testing
can be performed only while the system is disarmed. Testing the system should be
performed in both ELECTRICAL ROWER AC ON and STANDBY BATTERY
modes. Your neighbors' understanding and cooperation is very important. When
you are away from your residence (or commercial business),neighbors play an
important role. Advise them that you have a security system and ask them to notify
the proper authorities if your system is sounding. The burglar alarm typically has
a pulsing bell and a fire alarm has a steady horn sound. If the battery fuse lead is
opened, call your security representative for service.
Note: A
lighted zone indicator means thst at least one sensor of that
particular zone h8S been tested. It does not necessarfly mean that all
sensors of that zone were tested. W is recommended that you test your
system on 8 weekly basis.
1.
The system must be disarmed.
Use the zone I.D. card to determine the area of protection which corresponds to
2.
each zone.
To simplify testing, all zones should first be secured (READY light ON). If it
3.
is not possible to secure all zones prior to beginning the walk test mode, please
note that the control station will beep continuously as a result of the non-secure
zones. This will eliminate the advantages of the audible walk test mode,
although the zone indicator lights may still be relied upon for testing.
Press key 8 and hold for three seconds. The control station will beep three times
to signify entry into the TEST mode.
Violate a detection zone (open a door, window, etc.). The control station will
beep continuously and the indicator of the corresponding zone will light.
Secure the zone (close the door, window, etc.). The control station beeping will
cease.
The interior detection devices will also cause the control station to beep if
entering those protected areas when testing unless the INTERIOR is first turned
OFF. You may also want to walk test motion detection devices to check whether
the pattern is covering the areas of concern.
8.
Begin at step five to test the remaining sensors.
9.
Press the " * " key when finished testing.
insure proper operation. Cantact your security representative for com-
plate instructions on regular system malrttenence and testing prooe-
moved for any reason, test the system to see If the standby battery Is
adequately powertng thesystem. Re+onnect the transformer, secure to
the wallplate with the restraining teb machine screw, and test the system