Download Print this page

ADC TrueNet TracerLight TrueNet TracerLight Specifications page 4

Connector identification system

Advertisement

Specifications
(cont.)
oPTICAL (Multimode)
operating Wavelength:
Insertion Loss:
oPTICAL (Singlemode)
operating Wavelength:
Insertion Loss:
return Loss:
MeChANICAL (Singlemode and Multimode)
Vibration:
Flex Cycling:
Twist:
Mating Durability:
Tensile Load (Proof):
Impact:
eNVIroNMeNTAL (Singlemode and Multimode)
Thermal Age:
Thermal Cycle:
humidity Age:
* Release Pending
Note: 0.3dB max IL @ 850/1300 included with all assemblies.
Note: Now included with all flat polish (UPC) SC and LC singlemode connectors:
• 0.2 dB maximum insertion loss at both 1310 and 1550 nm
• 100% interferometer data
• ±50 nm recession
• <50 micron apex offset
• 10-25 mm radius of curvature
Web Site: www.adc.com
From North America, Call Toll Free: 1-800-366-3891 • Outside of North America: +1-952-938-8080
Fax: +1-952-917-3237 • For a listing of ADC's global sales office locations, please refer to our web site.
ADC Telecommunications, Inc., P.O. Box 1101, Minneapolis, Minnesota USA 55440-1101
Specifications published here are current as of the date of publication of this document. Because we are continuously
improving our products, ADC reserves the right to change specifications without prior notice. At any time, you may
verify product specifications by contacting our headquarters office in Minneapolis. ADC Telecommunications, Inc.
views its patent portfolio as an important corporate asset and vigorously enforces its patents. Products or features
contained herein may be covered by one or more U.S. or foreign patents. An Equal Opportunity Employer
103472Ae 12/07 revision © 2001, 2006, 2007 ADC Telecommunications, Inc. All rights reserved
850 and 1300 nm; all tested at both wavelengths
0.3 dB maximum
1310 and 1550 nm; all tests below apply at both wavelengths
PC: 0.2 dB maximum
APC: 0.5 dB maximum
PC: 57 dB minimum
APC: 60.5 dB minimum
GR-326 and FOTP 11; ∆IL < 0.3 dB; 3 planes, 6hrs. 10-55 Hz
GR-326 and FOTP 1; ∆IL < 0.3 dB; 100 cycles with 2lbs. load
GR-326; ∆IL < 0.3 dB; 3lbs; 5 turns, 9 cycles
FOTP-21A; ∆IL < 0.3 dB; 500 cycles
GR-326 and FOTP-6; ∆IL < 0.3 dB; 15 lbs. at 0º and 7.5 lbs. at 90º
GR-326 and FOTP-2; ∆IL < 0.3 dB; 8 drops from 1 meter (or 1.5 meters)
GR-326 and FOTP-4; ∆IL < 0.3 dB; 7 days at 85ºC
GR-326 and FOTP-3A; ∆IL < 0.3 dB; 7 days, -40º to 75ºC, 21 cycles
GR-326 and FOTP-5; ∆IL < 0.3 dB; 7 days at 75ºC and 95% RH