Batteryless telephone system with public address mode BLTS-1006 Table of contents Introduction ....................... 4 TERMS AND ABBREVIATIONS ................5 1 description and operation of the system .............. 6 1.1 Description ......................6 1.2 Technical specifications ..................7 1.3 System composition ..................... 8 1.4 Structure and operation ..................
Page 3
Operating manual 7 Transportation and storage ................39 8 Disposal ......................40 Appendix A SPTA kit list ..................41 Appendix B Description of the SC ................42 Appendix C Set of operation and maintenance documents ........64 Appendix D Settings of SC ..................65 Appendix E Connection of the SC ................
Batteryless telephone system with public address mode BLTS-1006 INTRODUCTION This Operating manual describes equipment of Battery less telephone system BLTS-1006 (modernized) (hereinafter referred to as the System). This operating manual (hereinafter – OM) describes composition, structure, spec- ifications, System components (hereinafter – SC) and instructions to ensure correct and safe operation of the System (intended use, technical service, current repair, storage and transportation), as well as information on System components disposal.
Operating manual TERMS AND ABBREVIATIONS Automatic circuit breaker Amplifier and pre-amplifier of voice signals of external communication de- vices Battery less telephone Battery less telephone communication Call button Check list CUESU Control unit for external signaling units Electric generator Energy storage Liquid crystal display LED «Inductor on»...
Batteryless telephone system with public address mode BLTS-1006 1 DESCRIPTION AND OPERATION OF THE SYSTEM 1.1 Description 1.1.1 The System is designed to provide telephone communication both in routine operation (if power is available or unavailable) and emergencies caused by failure (or de- energization) of shipborne communication systems.
Operating manual 1.2 Technical specifications The System ensures: a) application of BTC user network using several two- or three-wire channels and PSU (or without PSU); b) user may initiate and accept a call, hold communication session in BTC user network with / without connection to power mains; c) operation from an inductor (manual generator) or external PSU in the following modes: –...
Batteryless telephone system with public address mode BLTS-1006 The System may operate from the power mains and in autonomous mode (without connection to the power mains). Energy produced by generator rotation is stored by high capacity condensers in- tegrated in telephones and сommutator telephones.
Page 10
Batteryless telephone system with public address mode BLTS-1006 1.3.2 The System includes: a) commutator telephones: ‒ stationary, wall or panel mounted for 5, 15, 20 and 25 lines of pair communica- tion; ‒ portable for 5 lines of pair communication;...
Page 11
Operating manual SC name Code Installation conditions For special spaces, bridge, central control stations and accommoda- PS-103 tion areas. PS-103-20 IP22 TH-4M-S TH-4M-W TH-4M-S-C TH-4M-W-C TH-4M-S-AC For outside open spaces, special spaces, bridge, central control sta- TH-4M-W-AC tions and accommodation areas. Intercom helmet TH-4L-S IP56...
Batteryless telephone system with public address mode BLTS-1006 SC name Code Installation conditions L-24-B L-220-R L-220-О For outside open spaces, special spaces, bridge, central control sta- L-220-W tions and accommodation areas. IP56 L-220-G L-220-B RL-24-О For outside open spaces, special spaces, bridge, central control sta- RL-24-B tions and accommodation areas.
Page 13
Operating manual Figure 2 – Pair communication b) communication between the main station and user group (several lines) using сommutator telephones and telephones for pair communication and general list (all), see Figure 3; Figure 3 – Network based on сommutator telephones and telephones c) combined user network (using any combination of сommutator telephones and telephones) for communication (pair and general list (all)) of the main station within its group and users of other groups, see Figure 4.
Batteryless telephone system with public address mode BLTS-1006 Figure 4 – Combined user network Connection of the SC is carried out directly at Customer facilities. 1.4.2 The System operates in two modes: а) BTC mode – applied in case of power mains failure; the System users are pow- ered from inductor (manual electric generator), which is integrated into telephones (сom-...
Operating manual 1.6 Marking and sealing All SC have nameplates indicating a name of SC, identifier, serial number, weight, nominal values of main parameters and Manufacturer’s name. Сommutator telephones are delivered with names of user line switches; the names are produced using laser printer and photograph paper, inserted into transparent film pockets under a single toggle switch or group of toggle switches (depending on the model), using bold face «Arial», size 14.
Batteryless telephone system with public address mode BLTS-1006 2 DESCRIPTION AND OPERATION OF THE SYSTEM COMPONENTS 2.1 Description of the SC 2.1.1 Сommutator telephones The System includes three types of сommutator telephones: ‒ wall mounted PH2-хC-W (where х – 5, 10, 15, 20 or 25);...
Page 17
Operating manual Figure 6 – Connections of external signaling units to telephones (сommutator telephones) All сommutator telephones have LED light indicator of power status when power is supplied from the power source. All сommutator telephones have controls backlight which switches on automati- cally once the power is supplied from external source.
Page 18
Batteryless telephone system with public address mode BLTS-1006 All telephones ensure control (according to scheme – electric circuit switch) over external signaling units and repeat (if necessary) incoming call with light and (or) sound signaling. Connections of signaling units are shown in Figure 6.
Page 19
Operating manual Cables of headsets and intercom helmets with character «Р» in code (identifier) are equipped with waterproof connector for telephones (сommutator telephones) or socket PB-HS type. Headset or intercom helmet may be connected directly (using corresponding con- nectors or terminal block), or using external junction boxes and sockets PB-HS type, see Figure 5.
Page 20
Batteryless telephone system with public address mode BLTS-1006 2.1.5 Sockets Sockets PB-HS type ensure connection of communication devices to telephone (сommutator telephone). Socket has a waterproof connector and protective cover for con- nector. The System also includes PB-HS type socket to connect an audio recorder to tele- phone (сommutator telephone).
Operating manual 2.2 Operation of the SC 2.2.1 Сommutator telephones The System’s сommutator telephones are manufactured in metal painted steel cas- ings. The units are wall and panel mounted for installation in dry and humid premises. Use metal cabinet BLTS2-BO to install units on open deck. Сommutator telephones are applied for talk-back communication with BTC users.
Page 22
Batteryless telephone system with public address mode BLTS-1006 – Description of сommutator telephones and telephones LED light indicators Table 3 Control element Description Сommutator telephones and tele- 1 Light signaling of incoming call «Call» 2 Light signaling of outgoing call phones Сommutator telephones and tele-...
Page 23
Operating manual Energy received by user line during incoming call is supplied to SUIC and CUESU, and then actuates incoming call signaling; at the same time, it is supplied to USU and switches on light signaling of user line. Once user line toggle switch is actuated on USU, energy from user line is supplied to inputs VC1 and VC2;...
Page 24
Batteryless telephone system with public address mode BLTS-1006 Version 0.1...
Page 25
Operating manual 2.2.2 Telephones The System telephones PH2-1 type are modifications of сommutator telephone PH2-10C; they have the same construction, see LEDs and controls (except USU), and functional diagram in Table 2 and Figure 7. 2.2.3 Sockets The System sockets are wall mounted, waterproof type, equipped with protective cover, providing air-tight protection of connector’s contact parts against water;...
Page 26
Batteryless telephone system with public address mode BLTS-1006 Table 4 – Colours of globe types Globe colour Signaling unit White type Orange Green Blue (transparent) «+» - colour is available. «-» - colour is not available. 2.2.4.2 Relay unit Relay unit RBWSB type is manufactured in impact-resistant plastic casing, wall mounted;...
Page 27
Operating manual for PS-103-20), and automatic load сommutator telephone (to standby power). Power LED is located on the casing side. 2.2.6 External communication devices 2.2.6.1 Headsets Headset is an external communication device designed for two-way communica- tion together with telephones and сommutator telephones. Headsets HS-3, HS-3P types consist of microphone (middle noise immunity), and two telephones fixed on the metal headband.
Page 28
Batteryless telephone system with public address mode BLTS-1006 Intercom helmets are produced in three sizes. For the helmet sizes, see Table 6. Measure head size by perimeter of circle, in centimeters, back point - the most exceeding point of the head back, front point - above the brows. Use centimeter line to measure the size.
Operating manual 3 INTENDED USE 3.1 Operational limitations All SC shall be connected according to connection diagram and table of connec- tions issued for this order. All SC shall be grounded. 3.2 Usage preparations 3.2.1 Safety features Before using the System, provide the following steps: –...
Batteryless telephone system with public address mode BLTS-1006 If external power network is unavailable, do not provide any of abovementioned steps. The System is ready for operation immediately. 3.3 Use of the System Before using the System, make sure that you observed 3.2.2 and 3.2.3.
Page 31
Operating manual To reset call signaling, press receiver (communication device) PTT button, or «Reset call» button on telephone or relay unit RBWSB type (if any); or transmit a voice communication to the calling user (ready to communication), so that calling user stops calling (see 3.4.4.).
Batteryless telephone system with public address mode BLTS-1006 4 TECHNICAL SERVICE OF THE SYSTEM 4.1 General description Only qualified staff familiarized with the System composition, structure and op- eration features shall perform the TS. In order to provide safe and reliable operation of the System, the staff shall main- tain all types of TS: –...
Page 33
Operating manual Table 8 – Checklist № 1. Visual check of the SC Man-hours per To be done Routine 1 SC 1) check appearance of the SC; mechanical damage, paint defects must be absent; marking plates shall be present; legends are to be read easily; 2) clean up the SC surfaces with clean cloth;...
Batteryless telephone system with public address mode BLTS-1006 2) perform a control communication session (using telephone receiver and external communication de- vice), test connection of communication lines, 2 persons transmission of voice communication and quality 1 hour (speech legibility); during communication make...
Operating manual 5 CURRENT REPAIR 5.1 General description Within time of warranty the System is opened with witness of the Manufacturer representative drawing up an Act of opening. If the System is used outside its regular place of use, and SC failed, replacement of fuses and LEDs, etc.
Batteryless telephone system with public address mode BLTS-1006 6 CURRENT REPAIR OF SC 6.1 Сommutator telephones and telephones The list of possible malfunctions and troubleshooting is represented in Table 12. The staff shall eliminate malfunctions of сommutator telephones and telephones using SPTA kit portable.
Operating manual Malfunction Possible reasons Instructions No connection with calling Contact malfunction in 1 Check the toggle circuit, restore user, incoming call is set switch circuit (toggle) of contact (only for сommutator tele- 2 Replace the сommutator telephone user select phones) Not enough power for tele- phones operation (сommuta-...
Batteryless telephone system with public address mode BLTS-1006 6.3 Relay unit Table 14 – The list of possible malfunctions and troubleshooting of relay unit Malfunction Possible reasons Instructions Fuse malfunction in signaling Replace the fuse unit output circuit External signaling units do not...
Operating manual 7 TRANSPORTATION AND STORAGE The System must be stored in packaging inside areas complying with the required storage conditions (plus 5 ℃…plus 40 °С) without exceeding the concentration of dust, oil, moisture and aggressive impurities in the air for the working areas of production fa- cilities.
Batteryless telephone system with public address mode BLTS-1006 8 DISPOSAL New equipment, the parts of the System damaged during operation, and any used up equipment must not be disposed as standard household wastes, since they contain the materials suitable for re-use.
Operating manual APPENDIX A SPTA KIT LIST Table A.1 – SPTA kit Quantity Name Fuse 5A (5х20 mm) Fuse 2A (5х20 mm) Fuse 10A (5х20 mm) Bootlace terminal, wire 2.5 mm Bootlace terminal crimper 0.4…4.0 mm Cross screwdriver, PH1 Straight-blade screwdriver, blade width 3.5 mm, thickness 0.6 mm 0 or more* System units (select from 1.3.2) * Delivered on request, specify name and quantity at order.
Batteryless telephone system with public address mode BLTS-1006 APPENDIX B DESCRIPTION OF THE SC B.1 Telephones and сommutator telephones PH-1-W Telephone Description: single-channel telephone for applica- Technical specifications: tion in battery less communication systems. power consumption: Features: - wait mode 3 W;...
Page 43
Operating manual PH-1L Telephone Description: single-channel telephone for applica- Technical specifications: tion in battery less communication systems. power consumption: Features: - wait mode 3 W; operation in BTC and public address modes; - talk mode 15 W; number of lines: one; ...
Page 44
Batteryless telephone system with public address mode BLTS-1006 Сommutator telephones PH2-5C-W, PH2-10C-W Description: сommutator telephones for 5 or 10 lines Technical specifications: for application in battery less communication systems. power consumption: Features: - wait mode 3 W; operation in BTC and public address modes;...
Page 45
Operating manual Сommutator telephones PH2-5C-P, PH2-10C-P Description: сommutator telephones for 5 or 10 lines Technical specifications: for application in battery less communication systems. power consumption: Features: - wait mode 3 W; operation in BTC and public address modes; - talk mode 15 W;...
Page 46
Batteryless telephone system with public address mode BLTS-1006 Сommutator telephones PH 2-15C-W, PH2-20C-W, PH2-25C-W Description: сommutator telephones for 15, 20 or Technical specifications: 25 lines for application in battery less communication power consumption: systems. - wait mode 3 W;...
Page 47
Operating manual Сommutator telephones PH2-15C-P, PH2-20C-P, PH2-25C-P Description: сommutator telephones for 15, 20 or Technical specifications: 25 lines for application in battery less communication power consumption: systems. - wait mode 3 W; - talk mode – 15 W; Features: ...
Page 48
Batteryless telephone system with public address mode BLTS-1006 Portable telephone PH2-5C-PO Description: Telephone for 5 lines for application Technical specifications: in battery less communication system, portable. power consumption: Features: - wait mode 3 W; - talk mode – 15 W;...
Page 49
Operating manual Socket S-BLT Description: socket S-BLT is designed to connect port- Technical specifications: able telephone PH2-5C-PO. operating temperature: –40 ℃…+55 °C; IP rating: IP56; weight: 0.8 kg. Mounting: wall. Version 0.1...
Page 50
Batteryless telephone system with public address mode BLTS-1006 Socket PB-HS Description: remote connection point for headset to Technical specifications: telephone. material: aluminum; IP rating: IP56; Features: operating temperature: –40 °C...+55 °C; waterproof type; weight: 0.8 kg.
Page 51
Operating manual Metal waterproof cabinet BLTS-BO Description: Metal waterproof cabinet designed to Technical specifications: house SC on open deck and protect them against mois- operating temperature: –40 ℃ ...+55 °C; ture ingress. IP rating: IP56; weight: 12.4 kg. Features: ...
Page 52
Batteryless telephone system with public address mode BLTS-1006 Flashing lamp RL-24, RL-220 Description: flashing lamp (rotating) to ensure Technical specifications: light signaling of incoming call in noisy environ- power supply voltage: ment. - for RL-24 – 24 V DC;...
Page 53
Operating manual Sound signaling unit A-24, A-220 Description: Sound signaling unit for incoming Technical specifications: call in noisy environment. material – impact-resistant plastic (red or grey); power supply voltage: Features: - for A-24 – 24 V DC; waterproof type; - for A-220 –...
Page 54
Batteryless telephone system with public address mode BLTS-1006 Light signaling unit L-24, L-220 Description: Light signaling unit for incoming Technical specifications: call in noisy environment. material: polycarbonate (impact-proof); power supply: Features: - for L-24 – 24 V DC (20..28 V);...
Page 55
Operating manual Sound-light signaling unit AL-24, AL-220 type Description: Sound-light signaling unit for in- Technical specifications: coming call in noisy environment. material: plastic, impact-proof; power: Features: - for AL-24 – 8 W; waterproof; - for AL-220 – 11 W; ...
Page 56
Batteryless telephone system with public address mode BLTS-1006 Relay unit RBWSB-24, RBWSB-220 Description: external signaling unit to connect ex- Technical specifications: ternal alarm units; ensures switching of external power material: plastic; to the connected devices. input voltage: - for RBWSB-220 – 220 V AC 50 (60) Hz;...
Page 57
Operating manual Headset HS-3, HS-3P, HS-3P with angle connector Description: external communication device for Technical specifications: talk-back communication in noisy environment. headset type: passive, monophonic; close-talking response at frequency 300… 3400 Hz (idle run): Features: 16 dB; freedom to move; ...
Page 58
Batteryless telephone system with public address mode BLTS-1006 Headset HS-5, HS-5C, HS-5AC Description: external communication device for Technical specifications: talk-back communication in normal noisy environment. headset type: passive, monophonic; operating frequency range: 150…7000 Hz; Features: close-talking response at frequency 1000 Hz (idle run): ...
Page 59
Operating manual Intercom helmet type Size measurement, mm TH-4M-S (I) TH-4M-S (II) TH-4M-W (I) TH-4M-S (III) TH-4M-W (II) TH-4M-W (III) Note – I, II or III –intercom helmet size. Intercom helmet with microphone headset TH-4M-S, TH-4M-W, TH-4M-S-C, TH-4M-W-C, TH-4M-S-AC, TH-4M-W-AC Description: external communication device.
Page 60
Batteryless telephone system with public address mode BLTS-1006 Intercom helmet type Size measurement, mm TH-4L-S (I) TH-4L-S (II) TH-4L-W (I) TH-4L-S (III) TH-4L-W (II) TH-4L-W (III) Note – I, II or III –intercom helmet size. Intercom helmet with throat microphone...
Page 61
Operating manual Cord CE Description: to extend standard cord of external Technical specifications: communication devices. IP rating: IP56; Features: operating temperature: –40 ℃…+55 °C. cable ends CE-1.5, CE-3, CE-5, CE-7, CE-10: plug connector; cable ends CE-1.5BE, CE-3BE, CE-5BE, CE-7BE, CE-10BE: bare (crimped);...
Page 62
Batteryless telephone system with public address mode BLTS-1006 Power supply unit PS-103 Description: Power supply unit PS-103 designed to Technical specifications: power with unregulated DC voltage 24 V to different power supply: 110 V or 220 V AC 50 (60) Hz;...
Page 63
Operating manual Power supply unit PS-103-20 Description: Power supply unit PS-103-20 de- Technical specifications: signed to power with unregulated DC voltage 24 V power supply: 110 V or 220 V AC 50 (60) Hz; to different shipborne and industrial equipment. ...
Batteryless telephone system with public address mode BLTS-1006 APPENDIX C SET OF OPERATION AND MAINTENANCE DOCUMENTS Table C.1 – Set of operation and maintenance documents Name Identifier Note List of System elements List of SC One per object BTS-1006 for order № …...
Operating manual APPENDIX D SETTINGS OF SC Figure D.1 – Сommutator telephones PH2-12C, PH2-20C. Layout and assignment of terminals. Controls. Version 0.1...
Page 66
Batteryless telephone system with public address mode BLTS-1006 Figure D.2 – Сommutator telephones PH2-5C, PH2-10C. Layout and assignment of terminals. Controls. Version 0.1...
Page 67
Operating manual Table D.1 – Settings of telephones and сommutator telephones Settings Assignment Description element To adjust volume of Trimming resistor controls volume of incoming voice communi- incoming voice com- cation (sound in telephone receiver) from min. to max. value munication a) jumper JP5 is set –...
Batteryless telephone system with public address mode BLTS-1006 APPENDIX E CONNECTION OF THE SC Figure Е.1 – Connection of сommutator telephone PH2-2C and portable сommutator telephone PH2-5C-PO Version 0.1...
Page 69
Operating manual Figure E.2 – Connection of сommutator telephone PH2-2C and portable сommutator telephone PH2-1 Version 0.1...
Page 70
Batteryless telephone system with public address mode BLTS-1006 Figure E.3 – Connection of external communication devices Table E.1 – Description of HS headset wires with bare ends Pos. Description Wire colour М- brown (yellow shield) yellow М+ black Version 0.1...
Page 71
Operating manual Figure E.4 – Connection of socket PB-HS Version 0.1...
Batteryless telephone system with public address mode BLTS-1006 APPENDIX F THE SCOPE OF DELIVERY Standard scope of delivery includes: Battery less telephone system BLTS-1006 1 set* Operation and technical documents 1 set** SPTA kit 1 set*** ______________ * The System’s scope of delivery is specified at the stage of project design in the order list (or stated in Supply contract), see 1.3.
Need help?
Do you have a question about the BLTS-1006 and is the answer not in the manual?
Questions and answers