Accessories; Operation Specifications; Environmental Conditions - Acer LCD-S243HL Service Manual

Acer flat panel television user manual
Table of Contents

Advertisement

Acer

1.2 Accessories

Items
Description
O pt io n
2.

Operation Specifications

The unit should suffer no visible cosmetic damage and should operate with no degradation in display quality
during exposure to the operating conditions and after exposure to the non-operating conditions, in any
sequence.

2.1 Environmental conditions

Operating
Low Temperature
High Temperature
High Humidity
Altitude
Storage
Low Temperature
High temperature &low humidity +65°C/ 10% R.H.
Test Profile
Max. Wet Bulb Temp
Altitude
Notice:1.Altitude Ramp rate: <= 3,500 feet per minute
2. Packed properly with PE bag, cushion material, carton & seal tape
3. power off when test storage
VGA
Audio
cable
cable
manual
1.8m
1.8m
0°C (Relative Humidity is as low as possible), 12 hrs.
+40°C / 20% R.H., 12 hrs.
+32°C/ 80% R.H., 12 hrs
12,000 feet at 25°C (hold 3.5 hrs)
-30°C / humidity not controlled
+25°C/ 50%R.H.(2hrs)-> -30°C/ No R.H.(12hrs).-> +41°C/ 90%
R.H.(12hrs)->+65°C/ 10% R.H.(12 Hrs)->+25°C/ 50% R.H.(2hr)
39°C
40,000 feet at -30 °C (hold 1 hr)
User's
Warranty card
Multi
Multi
Specification
Acer –LCD-S243HL
Quick-start
Guide
Multi

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

S243hl