INTRODUCTION
The 50-HERK2 is an advanced planar microwave motion sensor designed
for commercial doors and gates. The sensor can differentiate between
people and vehicles. Its two relay outputs can be programmed
independently for a multitude of applications. Additional features include
cross-traffic optimization and slow-motion detection.
CARTON INVENTORY
•
50-HERK2 sensor with pre-wired 23' (7 m) 6-wire cable
•
Self-adhesive mounting template
•
Instructions
TOOLS AND HARDWARE NEEDED
•
Ladder
•
Tape measure
•
Level
•
Drill with 3/16" or 5 mm bit
•
3/16" or 5 mm mounting screws (2)
•
Screwdriver
•
4 AWG (5 mm diameter) wire stripper for cable sleeve
•
24 AWG (0.5 mm diameter) wire stripper for single wires
Other items recommended for installation:
•
Remote control (Model 50-HERK-RC2)
OVERVIEW
Mounting bracket
Inclination angle
hand-screws (2)
Cable
Clip for wide field sensing
Microwave planar module
50-HERK-RC2 remote control (not provided)
Required to access complete set of functions
for remote setup and operation
MICROWAVE MOTION SENSOR
for Commercial Doors
Failure to follow these safety precautions may cause DAMAGE to
sensor or objects, SERIOUS PERSONAL INJURY, or DEATH.
• This product is designed to be mounted above an overhead
commercial door.
• DO NOT use this product other than for its specified application.
• Observe ALL applicable local, national, and international door safety
standards, codes, and laws.
• ONLY trained and qualified personnel may install and initialize the
sensor.
• ONLY authorized factory personnel may perform hardware/software
changes or repairs to the product.
• The sensor should ONLY be operated from a safety extra low
voltage (SELV) system with safe electrical separation.
• ALWAYS consider the safety functions of your applications as a
whole, NEVER just in relation to one individual section of the
system.
• The installer is responsible for testing the system to ensure it
meets ALL applicable safety standards (e.g. UL 325).
• NEVER touch ANY electronic components or lenses.
• After accessing the inside of the sensor, ensure the cover/
protection seal is closed tightly to achieve designated protection
rating.
• ENSURE the commercial door operator has ALL of its monitored
entrapment protection devices installed and operational. This
sensor does NOT replace any entrapment protection devices.
Aluminum housing
DIP switches
Output 2 indicator (red LED)
Output 1 indicator (green LED)
R
Right button
L
Left button
MODEL 50-HERK2
Front cover
Cover screws (4)