4. Removing of Support Angle and Connectors.
1. Remove the 4 lock screws
2. Disconnect the following connectors from the Main Unit. (PD, LB1, LP, LW)
3. Disconnect the following connectors from the Power Unit. (PD, LB1, LB2)
4. Disconnect the following connector from the Inverter Unit. (CN101)
5. Disconnect the following connector from the LCD Control Unit. (CN1)
MAIN Unit
MAIN Unit
[PD]
and detach the Support Angle
LCD CONTROL Unit
[LB1]
[LP]
[LW]
.
POWER Unit INVERTER Unit
[CN1]
2
Support Angle
(Stand Support)
1 – 4
[CN101]
1
POWER Unit
[LB1]
[LB2]
[PD]