https://appliancetechmanuals.com Service Manual for Countertop Warmer IMPORTANT WARNING AND SAFETY INFORMATION WARNING READ THIS MANUAL THOROUGHLY BEFORE OPERATING, INSTALLING OR PERFORMING MAINTENANCE ON THE EQUIPMENT. WARNING FAILURE TO FOLLOW INSTRUCTIONS IN THIS MANUAL CAN CAUSE PROPERTY DAMAGE, INJURY OR DEATH. WARNING DO NOT USE OR STORE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
Service Manual for Countertop Warmer SPECIFICATIONS MODEL DESCRIPTION VOLTAGE AMPS HEIGHT WIDTH LENGTH ACTW-1 Countertop Warmer 120VAC 10-1/4” 14-1/2” 22-1/2” INSTALLATION Location WARNING The unit represented in this manual is intended for indoor use only and is designed for countertop REFER TO THE AMPERAGE DATA usage.
Page 5
https://appliancetechmanuals.com Service Manual for Countertop Warmer Figure 2 Electrical Schematic CAUTION: Never use an acid-based cleanser! Use alkaline based or non-chloride cleaning Be sure to clean all food products solutions. Anything containing chloride will damage from any stainless steel surface. the protective film on stainless steel.
https://appliancetechmanuals.com Service Manual for Countertop Warmer SERVICE INFORMATION Troubleshooting Procedure SYMPTOM CAUSE REMEDY Element Does Not Heat: Electrical power disconnected Plug unit into a GFI outlet Power source circuit breaker tripped Check circuit breaker and reset Bad infinite switch Check infinite switch using a multimeter Corroded or loose connections Check and tighten all connections...
https://appliancetechmanuals.com Service Manual for Countertop Warmer Infinite Switch Replacement Indicator Lamp Replacement Figure 3 Figure 4 Location of Infinite Switch (Bottom Removed) Location of Indicator Lamp Button General General The infinite switch (see Figure 3) is located on the The indicator lamp (see Figure 4) is located on the front of the control panel.
https://appliancetechmanuals.com Service Manual for Countertop Warmer Element Replacement 7. Use an ohm meter to test the new element for continuity. 8. Replace the element pan. 9. Using the tags, reconnect the element wires. 10. Install the bottom cover. 11. Plug the unit into a GFI outlet. Hi-Limit Thermostatic Switch Replacement Figure 5...
https://appliancetechmanuals.com Service Manual for Countertop Warmer Power Cord Replacement General Figure 8 The power cord is dressed along the side of the Power Cord Routing unit and exits at the rear (see Figure 8). 1. Disconnect unit from power source . 2.
Page 10
https://appliancetechmanuals.com Service Manual for Countertop Warmer NOTES...
Page 11
https://appliancetechmanuals.com Service Manual for Countertop Warmer NOTES...
Page 12
Duke Manufacturing Company 2305 N. Broadway St. Louis, MO 63102 Phone: 314-231-1130 Toll Free: 1-800-735-3853 Fax: 314-231-5074 www.dukemfg.com 219556...